2 documents15 error codes7 service modes
Available documentation
Service Manual
- Service Manual Refrigerator SMR 0019A 5421 5481disp model67 pg
- SMR0019A Side by Side 54215481 disp model Service Manual67 pg
MyPros+ Max
Diagnose your Viking RDDSB5421D.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (15)
CodeMeaning
1 FlashVCC3 Inverter diagnostic1 Flash (every 15 sec) - Compressor OFFVCC3 Inverter: No signal from control board or open thermistor1 Flash (every 15 sec) - Compressor ONVCC3 Inverter2 FlashesVCC3 Inverter diagnostic2 Flashes (every 5 sec)VCC3 Inverter3 FlashesVCC3 Inverter diagnostic3 Flashes (every 5 sec)VCC3 Inverter4 FlashesVCC3 Inverter diagnostic4 Flashes (every 5 sec)VCC3 InverterDOOR OPENDoor open alarmHIGH TEMPHigh temperature alarmNo FlashVCC3 InverteroPnOpen thermistor detectedPOWERPower loss alarmShrShorted thermistor detectedService modes (7)
- Forced Defrost1
- Forced Pull-Down (Forced Compressor Start)1
- Program Mode A1. Press and release ACTIVATE CONTROLS. 2. Press and release FAST COOL once. 3. Within 5 seconds…
- Program Mode B1
- Program Mode C1
- Sabbath Mode1
- Showroom Mode1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Viking refrigerator models
76,000+ service documents · 19,000+ error codes · 100+ brands