mypros+
Model reference

Wolf ICBCI152T/S

Cooktop

2 documents41 error codes5 service modes

Available documentation

Service Manual

  • Wolf Service Manual: ICB Integrated Modules (New 2015) — Service Manual77 pg
    Covers this model

Parts Manual

  • Wolf Parts Manual: ICB Integrated Modules (New 2015) — Parts Manual11 pg
    Covers this model
MyPros+ Max

Diagnose your Wolf ICBCI152T/S.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (41)

CodeMeaning
22Pad error on the control board touch pad system.30Data flash error, result of flashing software.31Invalid configuration between generator and control board.36Control temperature (TC) too high.39Controller options error.47LIN communication error between control board and generator.E00No error present.E01Appliance type is not valid; unit will try to reset and default to ICBSM if…E02Main RTD is open (Main RTD exceeds 538°C for 20 seconds in any mode).E03Main RTD is shorted (Main RTD exceeds -46°C for 20 seconds in any mode).E04RTD Steam Fill Sensor is open (RTD Steam Fill exceeds 538°C for 20 seconds in…E05RTD Steam Fill Sensor is shorted (RTD Steam Fill exceeds -46°C for 20 seconds…E06Main RTD/RTD Steam Fill sensing circuit error including calibration error…E07Ambient thermistor on power board is open.E08Ambient thermistor on power board is shorted.E09Ambient temperature above limit (default 103°C).E10Dry start at startup; ICBSM15TF/S RTD Steam Fill is 10°C more than Main RTD…E11Boil dry during cooking; ICBSM15TF/S RTD Steam Fill is 19°C more than Main RTD…E12Run-away liquid temperature; more than 11°C rise above set-point after…E13High temperature limit exceeded; ICBSM15TF/S RTD exceeds 121°C for more than 5…E14Communication link with display microcontroller is compromised.E15Communication link with cap-touch microcontroller is compromised.E16Power board internal clock or supply frequency out of spec.E17All Off LED not lit during cooking, or lit during Idle for more than 10 seconds.E18Front LO LED not lit during cooking, or lit during Idle.E19Rear LO LED not lit during cooking, or lit during Idle.E2Coil temperature too high.E20HOT LED does not reflect commanded state (e.g., not lit when RTD Steam Fill…E21LED display internal error (user interface error reported 3 times in 40…E22Config data in EEPROM corrupted; defaults used after micro reset.
View all 41 error codes

Service modes (5)

  • Diagnostic Mode - ICBCI152TF/S and ICBTM15TF/S["Enter Lock Mode.","Touch and hold the '+' pad and '-' pad simultaneously for 5 seconds.","After 5…
  • Diagnostic Mode - ICBSM15TF/S and ICBGM15TF/S["Enter Lock Mode.","Touch and hold the ON/OFF pad for 5 seconds.","After 5 seconds the unit enters…
  • Showroom Mode - ICBCI152TF/S and ICBTM15TF/S["Enter Diagnostic Mode.","Touch '+' pad seven times to reach Showroom Mode (seven dots…
  • Showroom Mode - ICBSM15TF/S and ICBGM15TF/S["Enter Diagnostic Mode.","Touch '+' pad six times to reach Showroom Mode (six dots…
  • User Options Mode - All Models["Unit must be in Idle Mode.","Touch and hold the Timer pad for 5 seconds.","After 5 seconds a…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started