Cove Dishwasher Error Code 050117
Wash pump drive system
Wash pump drive system: Under voltage Vbus error.
First step from the service manual
Replace the MCM assembly.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 050117.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 050117 means on a Cove dishwasher
Error code 050117 on a Cove dishwasher indicates an under voltage condition on the Vbus within the wash pump drive system. The Vbus, or DC bus voltage, is the internal high-voltage DC supply rail that powers the variable frequency drive (VFD) or motor control circuitry responsible for running the wash pump motor. When this rail drops below the expected operating threshold, the drive system cannot reliably control the pump motor, and the control board triggers this fault to protect the components from damage caused by insufficient power.
The Motor Control Module (MCM) assembly is the primary component governing this drive system. It converts incoming AC power to the regulated DC bus voltage and then synthesizes the appropriate output to spin the wash pump motor at the correct speed and torque. An under voltage Vbus fault typically means the MCM is not generating or sustaining the required DC bus level. This can result from internal component failure within the MCM itself, such as a failed rectifier, capacitor degradation, or a failed power stage. It can also stem from inadequate or unstable AC input power reaching the MCM.
Because the MCM assembly integrates the power conversion, motor drive, and monitoring functions into a single unit, individual component-level repair is generally not practical in the field. The diagnostic approach directs technicians to replace the MCM assembly as the first and primary corrective action. Before replacement, it is worth confirming that the incoming AC supply voltage to the unit is within specification and that wiring connections to the MCM are secure and free of corrosion or damage.
Source: manufacturer service documentation.
Common causes of 050117
- 01
Failed MCM Assembly
Part replacementThe Motor Control Module itself has an internal failure, such as degraded capacitors or a failed rectifier, that prevents it from maintaining the required DC bus voltage. This is the most common cause and the primary component targeted for replacement.
- 02
Low or Unstable Incoming AC Voltage
Wiring / connectionIf the AC supply voltage at the dishwasher's connection point is below the required operating range, the MCM cannot generate a sufficient Vbus. Check the wall outlet or junction box voltage with a multimeter to rule this out before replacing the MCM.
- 03
Loose or Corroded Wiring Connections
Wiring / connectionPoor connections in the power wiring harness leading to the MCM can cause voltage drops that trigger this fault. Inspect connector pins and terminal contacts for corrosion, burning, or looseness.
- 04
Wash Pump Motor Drawing Excessive Current
Part replacementA failing or seized wash pump motor can place an excessive load on the MCM drive circuit, causing the Vbus to collapse under the strain. If the MCM replacement does not resolve the fault, the wash pump motor should be inspected.
Frequently asked questions about 050117
What does 050117 mean on a Cove dishwasher?
Can I fix error code 050117 on my Cove dishwasher myself?
Will resetting my Cove dishwasher clear error code 050117?
Is it safe to use my Cove dishwasher while error code 050117 is active?
How much does it cost to repair error code 050117 on a Cove dishwasher?
78,000+ service manuals · 160,000+ error codes · 55+ brands