Daikin Heat Pump Error Code F3

Discharge pipe temperature control-discharge pipe thermistor temperature rises above 110°C (230°F), compressor stops.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the F3 error code actually means

Your Daikin heat pump detected that a pipe near the compressor got dangerously hot, so it shut itself off to prevent serious internal damage. This can happen when the system is low on refrigerant, when airflow is blocked, or when a temperature sensor is malfunctioning. The system will not restart normally until the underlying problem is identified and corrected.

Diagnostic procedure

The full F3 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check thermistors (discharge pipe, outdoor heat exchanger, outdoor temperature).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock F3 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of F3

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Faulty discharge pipe thermistor
  3. 3Restricted or dirty outdoor heat exchanger coil
  4. 4Blocked or failed expansion valve
  5. 5Faulty outdoor heat exchanger or ambient thermistor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about F3

What does F3 mean on a Daikin heat_pump?
F3 indicates that the discharge pipe thermistor recorded a temperature at or above 110°C (230°F), which caused the compressor to shut down as a protective measure. The discharge pipe carries hot, high-pressure refrigerant gas out of the compressor, and excessive temperature in this line signals an abnormal system condition. Common causes include low refrigerant charge, restricted airflow across the outdoor coil, a blocked expansion valve, or a defective thermistor. The unit will not resume normal operation until the fault condition is resolved.
Is it safe to keep running my Daikin heat pump with an F3 error?
No. The F3 error triggers a compressor shutdown specifically to prevent damage, so the unit will not run normally while the fault is active. Attempting to force operation by repeatedly resetting the unit without diagnosing the root cause risks permanent compressor damage, which is a much more costly repair. Address the underlying cause before returning the unit to service.
How much does it cost to repair an F3 error on a Daikin heat pump?
Repair costs vary significantly depending on the cause. Thermistor replacement is typically in the range of $150 to $400 including parts and labor. Refrigerant recharge or leak repair can run from $250 to $700 or more depending on the refrigerant type and extent of the leak. If the compressor itself has sustained damage from prolonged high-temperature operation, replacement costs can range from $1,200 to $2,500 or higher. Early diagnosis and repair will almost always result in lower total costs.
Can I fix an F3 error on my Daikin heat pump myself?
Some causes, such as a dirty outdoor coil blocking airflow, can be addressed by a knowledgeable homeowner through careful cleaning of the unit's exterior fins. However, refrigerant-related issues require a certified HVAC technician because handling refrigerant is regulated and requires specialized equipment. Thermistor testing and replacement is also a task best handled by a technician familiar with the unit's wiring and resistance specifications. Attempting to bypass or ignore the error is not recommended, as the protection exists to prevent compressor failure.
Will resetting my Daikin heat pump clear the F3 error?
A power reset may temporarily clear the fault code and allow the unit to restart, but if the underlying problem remains, the F3 error will return once discharge temperatures exceed 110°C again. Resetting does not repair the root cause and repeated compressor cycling under fault conditions accelerates wear. A proper diagnosis should be performed before relying on a reset as a solution.