Error code reference

Daikin Heat Pump Error Codes

111 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
00Normal operation, no fault detected.14Frequent high pressure faults detected (minor)16Frequent low pressure faults detected (minor)33High temperature fault on outdoor unit control board (minor)52Frequent compressor faults (minor)53Frequent outdoor unit control board and/or motor faults (minor)54Frequent low discharge superheat faults (minor)55Frequent high discharge temperature faults (minor)70Indoor EEV disconnection detected.73Liquid side thermistor abnormality (open or short circuit).74Gas side thermistor abnormality (open or short circuit).75Pressure sensor abnormality (open or short circuit).76Indoor unit77Indoor unit78Indoor unit9bLow indoor airflow with electric heat mode.A1Indoor unit PCB abnormality; the system cannot set the internal settings.A3Drain level control system abnormality-water level reaches upper limit and float switch…A5Freeze-up protection control (cooling) or heating peak-cut control (heating) activated.A6Indoor fan motor (DC motor) or related abnormality; detected rotation speed does not…AFHumidifier or related abnormality-water leakage from humidifier detected based on float…b0Blower motor not running due to fan/motor obstruction, power interruption, or…b1Blower motor communication error.b2Blower motor HP mismatch (incorrect size motor or invalid shared data).b3Blower motor operating in power, temp or speed limiting conditions.b4Blower motor current trip or lost rotor.b6Blower motor stops for over/under voltage or due to control board overheating.b7ID blower motor does not have required parameters to function; motor fails to start 40…b9Low indoor airflow without electric heat mode.C4Indoor heat exchanger thermistor 1 (liquid pipe) (R2T) or related abnormality-thermistor…C5Indoor heat exchanger thermistor 2 (R3T) or related abnormality-thermistor disconnected…C7Front panel open/close fault.C9Room temperature thermistor (R1T) or related abnormality-thermistor disconnected or…CEPresence sensor or floor sensor abnormality-sensor disconnected or shorted while unit is…CJRemote controller thermistor abnormality-remote controller thermistor disconnected or…d0Data not on network (no shared data on the network).d1Invalid data on network (wrong shared data on the network).d4Invalid memory card data (wrong memory card data).E1Outdoor unit PCB abnormality-microprocessor program runs out of control or zero-cross…E11System start-up test required at startup; installer should navigate to thermostat menu to…E12General memory error on outdoor unit control board.E13Frequent high pressure faults detected (critical); pressure higher than 4.2 MPa (605…E15Frequent low pressure faults detected (critical); pressure less than 0.12 MPa (17 PSIG)…E17Frequent compressor faults (stop valve issue, solenoid valve fault, compressor wire lost…E18Outdoor unit control board may need to be replaced (outdoor fan motor wiring or faulty…E19Frequent outdoor unit control board and/or fan motor faults.E20Outdoor EEV fault (EEV coil not connected or faulty).E21Frequent low discharge superheat faults; discharge pipe superheat excessively low and EEV…E22Frequent high discharge temperature faults; discharge temperature exceeds criterion…E23Discharge thermistor is out of range.E24High pressure switch is open.E25Outdoor air thermistor is open or shorted.E26Pressure sensor is not reacting properly.E27Outdoor coil defrost thermistor is out of range.E28Outdoor coil thermistor is out of range.E29Liquid thermistor is out of range.E30Outdoor unit control board may need to be replaced (wiring disconnected, faulty board, or…E32Outdoor unit control board experiencing high temperature faults (inverter cooling…E34Control board detected a high current condition indicating potential short circuit.E35Control board detected a high current condition (short circuit, overcharge, or faulty…E36Abnormal condition encountered during startup procedure.E37Outdoor unit control board may need to be replaced (outdoor fan motor wiring issue).E38Voltage related issue with the compressor detected (high or low voltage, lost phase).E39Outdoor unit control board may need to be replaced (thermistors inoperable or improperly…E40Control determines compressor requirement is different than compressor capability (memory…E41Low refrigerant condition detected.E42Low power supply voltage condition detected.E43High power supply voltage condition detected.E44Outdoor temperature outside recommended operational range.E47Unable to start System Verification test because indoor heat has been turned on by…E49Unable to enter Charging Mode because indoor heat has been turned on by thermostat.E5OL activation (compressor overload)-compressor overload detected through compressor OL.E50Voltage issue on the control board (high or low voltage from supply voltage or frequency).E51Potential communication issues detected by the outdoor unit control board.E56Outdoor suction thermistor is out of range.E57Sensing sweating on the cooling loop (3.5-5.0 ton only); outdoor liquid pipe temperature…E58Overload protection sensor for compressor is open.E6Compressor lock-detected by current waveform generated when applying high-frequency…E7DC fan lock (outdoor fan motor)-fan does not start in 15-30 seconds even when fan motor…E8Input overcurrent detection-current exceeds approximately 12.0-12.5A for 2.5 seconds with…EAFour way valve abnormality-room temperature and indoor heat exchanger thermistors not…EbSelecting 'no heater kit' and receiving electric heat demand.Eb0Estimated airflow from indoor subsystem is near 0 CFM.Eb9Estimated airflow from motor is lower than the airflow requirement.EdHeater kit dip switches not set properly (invalid heater kit selected).Ed0Control board does not have the necessary data for it to properly perform its functions…Ed1Control board does not have the appropriate data needed (invalid shared data or network…Ed2Airflow requirement is greater than indoor subsystem capability, or non-EEV indoor unit…Ed3Mismatch between shared data and control physical hardware.Ed4Memory card data has been rejected.EENo 24 volt power to control board, blown fuse or circuit breaker, or control board…EFAuxiliary switch open (high water level in evaporation coil or connected alarm device…F3Discharge pipe temperature control-discharge pipe thermistor temperature rises above…F6High pressure control in cooling-outdoor heat exchanger thermistor temperature rises…F8System shutdown due to compressor internal temperature abnormality-discharge pipe…H0Compressor system sensor abnormality; DC current voltage before compressor start-up is…H6Position sensor abnormality-compressor start-up failure detected through the position…H8DC voltage/current sensor abnormality identified based on compressor running frequency…H9Outdoor temperature thermistor or related abnormality-thermistor input voltage to…J3Discharge pipe thermistor or related abnormality; discharge pipe temperature is lower…J6Outdoor heat exchanger thermistor or related abnormality-thermistor input voltage to…L3Electrical box temperature rise-radiation fin temperature is above threshold with…L4Radiation fin temperature rise-radiation fin temperature is above threshold with…L5Output overcurrent detection-position signal error, rotation speed error, or output…P4Radiation fin thermistor or related abnormality.U0Refrigerant shortage detected.U2Low-voltage detection or over-voltage detection-abnormal voltage drop or rise detected by…U4Signal transmission error between indoor unit and outdoor unit-data sent from outdoor…U5Signal transmission error between indoor unit and remote controller-normal transmission…U8Signal transmission error between MAIN remote controller and SUB remote controller-normal…UAUnspecified voltage between indoor unit and outdoor unit; pair type and multi type are…

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.

More Daikin error codes