Daikin Heat Pump Error Code U5

Signal transmission error between indoor unit and remote controller-normal transmission does not continue for specified period.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the U5 error code actually means

Your Daikin heat pump is having trouble communicating with its remote control, and the connection has been lost long enough to trigger a fault. This often happens when two remote controls are both set to the same role and end up interfering with each other. Until the communication issue is resolved, the system will not operate normally.

Diagnostic procedure

The full U5 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if 2 remote controllers are both set to MAIN; if so, set one to SUB.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock U5 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of U5

Ranked by how often they cause this code
  1. 1Dual remote controllers both set to MAIN
  2. 2Loose or damaged signal wiring
  3. 3Faulty remote controller
  4. 4Defective indoor unit control PCB
  5. 5Incorrect remote controller model or compatibility mismatch

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about U5

What does U5 mean on a Daikin heat_pump?
U5 indicates a signal transmission error between the indoor unit and the remote controller. The system detected that normal communication was not maintained for a specified period and shut down as a result. This is a communication fault, not a refrigerant or mechanical failure. It requires diagnosing the remote controller wiring, addressing settings, and potentially the control PCB.
Will resetting my Daikin heat pump clear the U5 error?
A power cycle reset may temporarily clear the U5 code, but the error will return if the underlying communication problem is not corrected. Simply resetting the unit without addressing the root cause, such as a wiring issue or dual MAIN controller conflict, will not result in a lasting fix. Resolve the communication fault before relying on normal operation.
How much does it cost to repair a Daikin U5 error?
If the fix is simply reconfiguring one remote controller from MAIN to SUB, there is no parts cost and minimal labor involved. If the signal wiring needs repair, costs are generally low, typically in the range of $50 to $150 for a service call and minor wiring work. A replacement remote controller can range from $80 to $250 or more depending on the model, and an indoor unit control PCB replacement can cost $200 to $600 or higher including labor.
How do I fix a U5 error on my Daikin heat pump?
Start by checking whether you have two remote controllers connected to the indoor unit and verify that they are not both set to MAIN. If so, set one to SUB and power cycle the system. If the error persists, inspect the signal wiring between the remote and the indoor unit for loose terminals or damaged cables. If wiring looks correct, try swapping in a compatible remote controller to rule out a faulty unit.
Is it safe to run my Daikin heat pump with a U5 error?
The U5 error will typically prevent the system from operating normally, so running the unit is not usually possible until the fault is cleared. U5 is a communication fault rather than a safety-critical failure like a refrigerant leak or electrical short, but you should not attempt to bypass the fault. Address the wiring and controller configuration before resuming use.