Daikin Heat Pump Error Code UA

Unspecified voltage between indoor unit and outdoor unit; pair type and multi type are interconnected.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the UA error code actually means

Your Daikin heat pump is showing this error because the indoor and outdoor units are not compatible with each other and should not be connected together. Think of it like trying to connect two devices that were never designed to work as a pair. A qualified technician will need to verify that your indoor and outdoor units are a matched set before the system can run properly.

Diagnostic procedure

The full UA procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check the combination of the indoor and outdoor unit for compatible models.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock UA procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of UA

Ranked by how often they cause this code
  1. 1Incompatible system type pairing
  2. 2Mismatched model combination
  3. 3Incorrect interconnecting wiring
  4. 4Replacement unit of wrong type installed

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about UA

What does UA mean on a Daikin heat_pump?
The UA error code indicates that there is an unspecified voltage condition between the indoor and outdoor units caused by an incompatible unit pairing. Daikin heat pumps detect when a pair-type indoor unit is connected to a multi-type outdoor unit, or when another mismatched combination is in use. The system will not operate normally until compatible units are connected. A technician must verify the model numbers and system types of both units to resolve this fault.
Will resetting the Daikin heat pump clear the UA error?
Resetting the unit will not clear the UA error code if the underlying cause is an incompatible indoor and outdoor unit combination. The fault will return immediately upon startup because it reflects a fundamental system configuration problem. The error will only clear permanently once the correct compatible units are connected and the system recognizes a valid pairing.
How much does it cost to fix a Daikin UA error code?
If the error is caused by incorrect wiring, repair costs are generally limited to a service call fee, typically in the range of $75 to $150 depending on your location. If the indoor or outdoor unit must be replaced due to an incompatible model pairing, costs will increase significantly and depend on the unit type and size required, with equipment and installation potentially ranging from several hundred to several thousand dollars.
Can I fix a Daikin UA error code myself?
The first step you can take is to locate the model numbers on both your indoor and outdoor units and confirm they are a compatible pair. However, if the units are determined to be incompatible, resolving the issue requires replacing one of the units with the correct model, which is work that should be performed by a licensed HVAC technician. Incorrect wiring is another potential cause that a technician should inspect and correct.
Is it safe to run my Daikin heat pump while the UA error is active?
The system will generally not operate normally while the UA fault is present, as it is designed to prevent operation when an incompatible unit combination is detected. You should not attempt to override or bypass this fault. Leaving incompatible units interconnected can place abnormal stress on the control boards and wiring, so the issue should be addressed before attempting to use the system.