Electrolux Air Conditioner Error Code LC
Compressor failure start-up (start-up failure).
Compressor failure start-up (start-up failure).
First step from the service manual
Verify compressor wiring is correct and connection sequence is proper; ensure compressor stop time exceeds 3 minutes before restart.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for LC.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What LC means on a Electrolux air conditioner
The LC error code on an Electrolux air conditioner indicates a compressor start-up failure. This means the unit attempted to start the compressor but the compressor did not successfully reach operating speed or status within the expected timeframe. The compressor is the core refrigerant-pressurizing component in the sealed refrigeration circuit, and a failure to start properly triggers this code as a protective shutdown to prevent motor burnout or electrical damage.
The most frequent cause of this fault is a restart attempt made too soon after the previous shutdown. Compressors require a minimum off time, typically exceeding 3 minutes, to allow refrigerant pressure to equalize across the high and low sides of the system. Attempting a restart before pressure equalizes places extreme mechanical load on the compressor motor at start-up, which the control board detects as a failure condition. Incorrect wiring at the compressor terminals, including improper phase sequence or loose connections, can also prevent successful start-up and trigger this code.
Additional causes include a failed compressor capacitor (on single-phase units), an internally seized or weakened compressor motor, or supply voltage outside the acceptable operating range. Diagnosing the root cause requires confirming proper wiring and connection sequence at the compressor terminals, verifying that the minimum stop time has been observed, and checking supply voltage stability before suspecting internal compressor failure.
Source: manufacturer service documentation.
Common causes of LC
- 01
Insufficient compressor stop time before restart
Wiring / connectionIf the unit is restarted less than 3 minutes after shutting off, refrigerant pressure has not had time to equalize, causing excessive load on the compressor motor at start-up. Allow the unit to remain off for at least 3 minutes and retry.
- 02
Incorrect compressor wiring or connection sequence
Wiring / connectionImproperly connected compressor terminals or incorrect phase sequencing can prevent the motor from starting correctly. Inspect all wiring connections at the compressor for proper seating, correct terminal assignment, and secure contact.
- 03
Faulty or weak compressor start capacitor
Part replacementOn single-phase units, a failing start capacitor reduces the torque available to the compressor motor during start-up, which can cause a failure-to-start condition. A capacitor showing low or no capacitance on a meter indicates it needs replacement.
- 04
Supply voltage out of acceptable range
Wiring / connectionLow or unstable supply voltage reduces available starting torque for the compressor motor and can cause repeated start-up failures. Measure the incoming voltage at the unit with a multimeter to confirm it falls within the rated operating range.
- 05
Seized or internally failed compressor
Part replacementAn internally worn or seized compressor motor will fail to turn even under correct electrical conditions, triggering the LC code. This is confirmed when wiring, capacitor, voltage, and restart timing are all verified correct but the fault persists.
Frequently asked questions about LC
What does LC mean on a Electrolux air_conditioner?
Can I fix the LC error on my Electrolux air conditioner myself?
Is it safe to keep using my air conditioner when the LC code appears?
Will resetting the unit clear the LC error code?
How much does it cost to repair an LC compressor fault on an Electrolux air conditioner?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass