Electrolux Air Conditioner Error Codes
49 error codes for Electrolux air conditioner models. Each links to the full diagnostic procedure from the service manual.
CodeDescription
C5Jumper cap malfunction protectionE1System high pressure protectionE2Anti-freezing protectionE3System low pressure protectionE4Compressor high discharge temperature protection.E5AC overcurrent protectionE6Communication malfunction between indoor and outdoor units.E8High temperature resistant protection (overload/high temperature).EEEEPROM malfunction on outdoor control panel.EULimit/decrease compressor frequency due to high IPM module temperature.F1Indoor ambient temperature sensor open or short circuited.F2Indoor evaporator (tube) temperature sensor open or short circuited.F3Outdoor ambient temperature sensor open or short circuited.F4Outdoor condenser temperature sensor open or short circuited.F5Outdoor discharge temperature sensor open or short circuited.F6Limit/decrease compressor frequency due to overload condition.F8Decrease compressor frequency due to overcurrentF9Decrease compressor frequency due to high discharge temperatureFHLimit/decrease compressor frequency due to anti-freezing protectionFoRefrigerant gathering/recovery modeMyPros+ Max
Get the full diagnostic procedure for any Electrolux air conditioner error code.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts
- Verified part numbers when replacement is required
Get started
$29/month · Cancel anytime · Or $9.95 3-day pass
H0Decrease compressor frequency due to high temperature resistant during heating…H1Defrosting modeH2Static dedusting protection.H3Compressor overload protection.H4System abnormalH5IPM module protection.H6Indoor fan motor locked/blocked protectionH7Compressor desynchronizing (loss of synchronism) protection.HCPFC (Power Factor Correction) protection.L3Outdoor DC fan motor malfunctionL9Power protectionLCCompressor failure start-up (start-up failure).LPIndoor unit and outdoor unit do not match.P0Compressor minimum frequency test state.P1Compressor rated frequency test state.P2Compressor maximum frequency test state.P3Compressor intermediate frequency test state.P5Overcurrent protection of compressor phase current.P7Module temperature sensor circuit malfunction.P8Module high temperature protectionPHDC bus-bar voltage too high.PLDC bus-bar voltage too low.PUCapacitor charging malfunction on outdoor unit.U1Compressor phase current detection circuit malfunction.U3DC bus-bar voltage dips/sagU5Malfunction of complete unit current detection circuit on outdoor unit.U7Four-way valve abnormalU8Zero-crossing inspection circuit malfunction of IDU fan motorU9Outdoor unit zero-crossing detection malfunction / whole unit current testing…