Error code reference

Electrolux Dishwasher Error Codes

151 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
01-09Hours delay before start (delay start countdown).ALL LEDs solidAll LEDs illuminated solid indicates a power failure has occurred.CdDisplayed once the program has been entered, START/CANCEL is pressed, and after a 10…CEConfiguration errorCLDisplayed when wash cycle has been completed and SANITIZE was not selected or SANITIZE…CLEANShows completion of cycle; indicator light will switch off when door is opened.DRYINGDrying portion of cycle is active.E1Water inlet time too long-water is not entering the dishwasher within the expected…E2Drain time too long-water is not draining within the expected timeframe.E3Drain time too longE4Heating time too long without reaching the required temperatureE5Abnormal temperature-short circuit or defective temperature sensor.ErMembrane switch failureEr 01Leak detector activatedEr 02ThermistorEr 03Wash PumpEr 04Drying DamperEr 05Upper FanEr 06Lower FanEr 07Drain ValveEr 08Tactile or touch switchEr 09CommunicationsEr 10Mains RelayEr 11Drain valveEr 12Drain ValveEr 13System FailureEr 14System ErrorF0Pressure switch signal does not stabilize on FULL within dynamic fill time (T.SHdIndicates a water heat delayHOHeat delayhsThe control has sensed a problem with the Hall effect sensor in the wash motor.i0Water tap closed-pressure switch level not reached within 60 seconds during a fill step.i0 (10 blinks)Spray arm blocked-spray arm rotation not detected at program start, beginning of each…i0 (11 blinks)Turbidity sensor fault-the calibration turbidity signal is not reached within 15 seconds.i0 (12 blinks)Communication error-communication with the user interface is disrupted (EDW2000 only).i0 (13 blinks)Tacho fault-no tachometer signal detected for 5+20 seconds while circulation pump is…i0 (14 blinks)Fill time error-the time limit during the fill process has been exceeded.i0 (2 blinks)Drain pump fault-pressure switch reset point not reached within 120 seconds during…i0 (3 blinks)Aqua-Control activated-the Aqua-Control system has shut off the inlet valve due to a leak…i0 (5 blinks)Circulation pump triac short circuit-tacho signals detected while the circulation pump is…i0 (7 blinks)NTC temperature sensor short circuit or open circuit.i0 (8 blinks)EEPROM communication error-communication failure with external EEPROM.i0 (9 blinks)Checksum error-MCF or CCF variant programming checksum mismatch, detected only after…i00Low or near-zero supply voltage detected; electronics pause all operations when voltage…i10Water fill time-outi11Water tap closed or low fill detected during dynamic fillingi2Drain pump faulti20Slow or no drain problemi3Aqua-Control faulti30Intervention of anti-flooding system (the drain pump switches on); the cycle is…i40Analogue Pressure Sensor problemi41No pressure sensor signali42Calibration invalidi43Analog pressure sensor signal too highi44Analog pressure sensor signal too lowi45Pressure sensor calibration invalidi46Pressure sensor calibration invalidi5Circulation pump triac short circuiti50Motor triac short-circuitedi51AC wash pump motor problemi52Wash pump BLDC motor abnormal high current detectedi53WP BLDC (3-phase) motori54Wash pump BLDC motor will not follow / rotor is lockedi55DCLink low voltagei56DCLink overvoltagei57MCB Vbat voltage plausibility / ADC faulti58WP motor connectori59Wash pump current read ADC faulti5APlatform-dependenti5BWP/DP current problem suspectedi5CDrain pump BLDC motor abnormal high current detectedi5DDrain pump BLDC motor high current (software)i5EDrain pump BLDC motor will not follow / rotor is lockedi5FDP motor connectori60Overheatingi61Heating over temperaturei62Heater relay damagedi63Heating system error 1 (newer platformsi64Heater unit resettablei65Heater unit failed (newer platforms)i66Heating system error 2i67Heating system error 3i69Water temperature too highi6AHeater NTC sensor measurement value out of allowed range.i6BTemperature timeouti6CHeat exchanger efficiency lowi7NTC sensor faulti70NTC thermistor value out of rangei8EEPROM communication errori80Auto door opener malfunctioni81Automatic door opener warningi82Water recycling valve warningi9Checksum error MCF/CCFi90Check sum error in model programming (MCF) or CCFi91MCF checksum errori92CCF checksum errori93UIDATA checksum errori94UIDATA version mismatchi95UIDATA checksum type mismatchiASpray arm blockediA0Spray arm not rotatingiB0Turbidity sensor problemiB1Turbidity sensor communication lostiB2Turbidity sensor insufficient energy for calibrationiB3Turbidity sensor out-of-range calibration erroriB4Turbidity sensor too noisy during calibrationiCCommunication erroriC0Communication problemiC1MACS bus communication problemiC2ADSI communication problemiC3Communication between circuit boards failedidTacho faultid0Problems with the washing motoriD1Wash motor tacho critical signaliE0Flow diverter position error (spray arm level)iFFill time erroriF0Water replenishment time-out (3 times during the T.SiF1High water levelLD10 on onlyProgramming error when forming machine modelsLD9 off, LD10 off, LD11 onHeating errorLD9 off, LD10 on, LD11 offDischarge pump errorLD9 off, LD10 on, LD11 onTacho errorLD9 on, LD10 off, LD11 offWater tap closedLD9 on, LD10 off, LD11 onNTC sensor errorLD9 on, LD10 on, LD11 offAqua-ControlLD9 on, LD10 on, LD11 onRecycling pump triac short circuitLD9:off LD10:off LD11:onHeating errorLD9:off LD10:on LD11:offDischarge pump errorLD9:off LD10:on LD11:onTacho errorLD9:on LD10:off LD11:offWater tap closedLD9:on LD10:off LD11:onNTC Sensor errorLD9:on LD10:on LD11:offAqua-ControlLD9:on LD10:on LD11:onRecycling pump Triac short-circuitLOThe control has received a signal from the rinse aid dispenser that the rinse agent level…LocChild Lock is engaged; all buttons except AIR DRY are disabled and no new selections can…LSRinse aid empty-dispenser needs refilling.No displays (LD9:off LD10:off LD11:off)Programming error when forming machine modelsOPTION LED's FlashingAll option LEDs flashing indicates a power failure has occurred; the control needs to be…PADoor not properly closed.PFPower failurerAThe control has sensed a problem with the reed switch in the rinse aid dispenser.SADisplayed when SANITIZE option was selected and dishwasher has reached sanitize…SANITIZEDThe sanitization criteria has been met; indicator light switches off when door is closed.SiOverheatingSSSalt supply depleted-salt container needs refilling.START LED flashingThe START LED will flash when the door is opened during a cycle.STATUS LED's FlashingThe STATUS LEDs that were lit when the door was opened will flash and stay lit…tuThe control has sensed a failure in the turbidity (soil) sensor while in the Water…uFIn the dry mode, the control does not receive proper feedback from the vent that the fan…uoThe control does not receive the proper indication that the vent is closed; after 5…WASHINGWashing portion of cycle is active.

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.