Error code reference

Electrolux Dishwasher Error Code i10

Water fill time-out: the pressure switch has not switched to FULL within 90 sec during static filling, or fails to switch to FULL during the first 60 sec of dynamic filling at 2800 RPM.

SourceElectrolux Dishwasher - Full Service Manual: EDW 2503-LCD & DIVA SeriesSection 9.2.1, page 30

Diagnostic procedure

The full i10 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check that the tap is open and water mains pressure is adequate; check fill solenoid, wiring, pressure switch on water circuit, level pressure switch, and main board for short circuit on solenoid triac.

SourceElectrolux Dishwasher - Full Service Manual: EDW 2503-LCD & DIVA SeriesSection 9.2.1, page 30

More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock i10 procedure $9.95

Or subscribe: $29/month for all codes plus Max diagnostics, with 70 Max messages a day. Plus applicable tax.

Where this code is documented

17 manuals in the MyPros+ library document this code for Electrolux dishwasher.

Models covered by the manuals that document this code

More models are covered than are listed here.