Error code reference
Electrolux Oven Error Codes
190 error codes documented with diagnostic procedures.
Have your model number? Get codes specific to your unit.
ACFAir filter absentACSSACS software version (inside ACU board) incompatible with present UI SW version.ACUMCommunication error between ACU and UI boardsACUSACU software version (main uC) incompatible with present UI SW version.ASCHComponent compartment temperature warning (NCC)bAttBattery is low due to ageing.bCoMCommunication impossible with PMACS channelBEtcError, excessive time on closing operation of the vent valve (VV1) during cleaning.BEtoError, excessive time on opening operation of the vent valve (VV1) during cleaning.BEtrBoiler excessive temperature raising time (Tbol)BhtcWarning on excessive time on closing operation of the vent valve (VV1) during cookingBhtoWarning on excessive time on opening operation of the vent valve (VV1) during cookingbntCBoiler SSR NTC failure (NHSB)BoLtBoiler water loading timeout (EV5)bSHtBoiler SSR NTC overtemperature (NHSB)bSOtBoiler SSR NTC overtemperature (NHSB)butnOne of the panel buttons is permanently blocked.C3The oven door is not fully closed, preventing the pyrolytic cleaning function from…CdoCleaning drawer absent (DRS)CE1Wrong parameter configurationCFCheck FoodCFbLCooling fan stopped (FAN1-2-3)CLnSelf-clean cycle is in progress and the door is locked.CntCCavity NTC (NTC3) failureCPUAACS micro does not communicateCPUtTC microprocessor does not communicateCSHtCavity SSR NTC overtemperature (NHSC)CSOtCavity SSR NTC overtemperature (NHSC)d-OOven door was opened during steam clean cycle.dESCDescale boiler warningdrDoor open reminder during broil modeEOven control has detected a fault or error condition (generic E code displayed on control…EbOLBoiler thermocouple failure (TBOI)EbYPQuenching thermocouple failure (TQS)ECEdBottom cavity thermocouple failure (TCAV DWN)ECEuTop cavity thermocouple failure (TCAV UP)ECLtCleaning table not present for the model and detergent type in useEComUser interface cannot communicate with any other board for more than approximately 15…EGA0No valid GAS table present in the oven.EGAdWrong GAS table data.EGAtGAS table for this appliance model not found.EH2OWater measured inconsistent with valves state (FM)ELMbLambda sensor failureEntCComponent compartment NTC failure (NCC)EotdHigh temperature on drain (NM8)Epr1Single point core probe failureEpr6Six points core probe failureERREURSensor cook mode failed to correctly detect steam/vapor during cooking of foods other…ERRORSensor did not detect vapor properly during sensor cooking (not popcorn).ErtcFailure on RTC (real-time clock)ESCHComponent compartment temperature error (NCC)EStdFail on NTC safety hydraulic drain (NM8)EtbBoiler safety switch triggered (TSB)EtCCavity safety switch triggered (TSC)EtUbBoiler over temperature (TBOI)EtUCCavity over temperature (TCAV)FElectronic control has detected a fault condition; the oven control beeps and displays an…F1Control failureF10The oven control has sensed a potential runaway condition in the lower oven; the…F102The oven door is not fully closed or the door lock is defective.F11Shorted key detectedF13Incorrect EEPROM checksumF14Misconnected flat cableF15Controller self check failedF2Communication failureF20Communication problem between the User Interface Board and the Appliance Control BoardF21Communication problem between the User Interface Board and the Appliance Control BoardF23The controller failed to communicate with the (upper) convection fan and oven lights…F24The controller failed to communicate with the lower convection fan and oven lights…F25No zero cross signal detected on the upper or lower convection fan and oven lights…F26Missing lower oven select signal on the lower oven convection fan and oven lights control…F3Oven probe problemF30Open RTD sensor probe/wiring problemF31Shorted RTD sensor probe/wiring problemF4Electronic control has detected a fault condition (codes F1 through F10 indicate various…F43The microwave external cooling fan speed (as read by the tachometer input of the…F44The microwave external cooling fan speed (as read by the tachometer input of the…F5Electronic control has detected a fault condition (codes F1 through F10 indicate various…F6Electronic control has detected a fault condition (codes F1 through F10 indicate various…F61Loss of zero-cross synchronization signal at the Appliance Control Board (ACB).F62Loss of the zero-cross synchronization signal at the User Interface Board.F7Electronic control has detected a fault condition (codes F1 through F10 indicate various…F8The oven door was left open and controls were set for the self-cleaning cycle.F80Communication problem between the User Interface Board and the Microwave Control BoardF81Damper error (Icon model only)F82Microwave thermistor open error (Icon model only)F83Fire detected in the microwave oven cavity, sensed by sudden changes of the microwave…F84Communication problem between the User Interface Board and the Microwave Control BoardF9Latch motor problemF90Motor Door Latch mechanism failureFA8HOven worked 8 hours without air inlet filterFd00Lower motor short circuitFd01Lower motor overcurrentFd02Lower motor speed inconsistencyFd03Lower inverter under voltage DCFd05Lower inverter over voltageFd06Lower inverter outgoing phases open circuitFd07Lower inverter high temperatureFd08Lower motor thermal safety tripping (Klixon)Fd09Lower inverter over torqueFd10Lower inverter drive interlock failureFd11Lower inverter undervoltage ACFd12Lower inverter overvoltage ACFd13Lower inverter communication errorFd14Lower inverter parameter configuration errorFd15Lower inverter alarm state.Fd16Lower inverter alarm state.Fd17Lower inverter outgoing phases open circuitFILSBoiler level under working timeout (WL)FLA1The FLASH EPROM ID is different as expectedFLA2Communication channel between FRAM and microcontroller is malfunctioning or blocked.FLEESPI-FLASH memory block erase error (4kb block).FLrESPI-FLASH memory reading error.FLUESPI-FLASH memory writing error.FrA1The FRAM ID is different as expectedFrA2The FRAM power fail data calculated MD5 is different to the stored one.FrMCSoftware errorFrrEFRAM memory reading error.FrUEFRAM memory writing error.FSnrCooling fan speed not reachable (FAN1-2-3)FU0Upper motor short circuitFU1Upper motor overcurrentFU10Upper inverter drive interlock failureFU11Upper inverter undervoltage ACFU12Upper inverter overvoltage ACFU13Upper inverter communication errorFU14Upper inverter parameter configuration errorFU15Upper inverter alarm state.FU16Upper inverter alarm state.FU17Upper inverter outgoing phases open circuitFU2Upper motor speed inconsistencyFU3Upper inverter under voltage DCFU4Upper inverter over voltageFU5Upper inverter outgoing phases open circuitFU6Upper inverter high temperatureFU7Upper motor thermal safety tripping (Klixon)FU8Upper inverter over torqueFU9Upper inverter interlock circuit failureGbbUBoiler gas burner lockedGbCdCavity lower burner lockedGbCUCavity upper burner lockedGrCoGrease collector openedHd01Water solenoid valve EV1 not workingHd02Water solenoid valve EV2 (quenching valve) not workingHd03Cavity drain valve BV3 not workingHd05Water solenoid valve EV5 not workingHd06Boiler drain valve BV6 not working.Hd07Water solenoid valve EV7 not workingHd08Cleaning pump M8 not workingHd11Water solenoid valve EV11 not workingHd12Water solenoid valve EV12 not workingHdPPLiquid cleaning pumps not workingHFnIISG is active but humidity does not increasehod1Hood errorHotOven is too hot for the door to unlock after a clean cycle; displayed until oven cools…HtdDrain temperature above safety limit (NM8)InuSInverter software version (YODA board) incompatible with present UI SW version.LOCDoor is locked (displayed during self-clean cycle or when control lock is engaged).LPInWorking probe on, safety probe off (WL-SL)MCtMInverter top not identified (MD1)nIU1Communication impossible with NIU board.nIUCNIU configuration not valid.nIUHNIU unknown.nIUPNo valid PNC and SER are found for connectivity.nIUSNIU SW version is incompatible with UI SW version.PCCEOne or more parameters failed the consistency check and required an automatic value…PdEFMemorized default parameters corruptedPFPower failure indicationPFACMemorized parameters corruptedPFOrOne or more factory parameters are out of range.PUOrOne or more user parameters are out of range.PUSrThe user parameters calculated MD5 is different to the stored oneRROven racks and/or oven rack supports have not been removed before starting the…rtc1Communication channel between the RTC and the microcontroller is malfunctioning or…SbbUBoiler 1 burner fan does not reach set speed (VTBU)SbCdCavity down burner fan does not reach set speed (VTCD)SbCUCavity up burner fan does not reach set speed (VTCU)SCbLAppliance is ON but ON/OFF switch feedback still OFFSFSabbath mode failureSLUSBoiler water level under safety for more than X minutes (SL)tCMSTC software version (inside ACU board) incompatible with present UI SW version.U015No water in boilerUrt2The RTC stopped flag is active even after the power on recovery procedureUrt3The RTC internal oscillator is malfunctioningUSdCError during creation of a directory on the USB key.USFCError during closure of a file on the USB key.USFOError during creation / opening of a file on the USB key.USFUImpossible to write on the USB keyUSrEError during reading of a file on the USB key.USUEError during writing of a file on the USB key.
Get the full diagnostic procedure for any code
Step-by-step tests, expected values, wiring diagram references, and verified part numbers.
Get Started $9.95 3-day pass$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.