Electrolux Oven Error Code EGAt
GAS table for this appliance model not found
GAS table for this appliance model not found - stops machine. Software missing.
First step from the service manual
Download latest SW version from AGELUX and upgrade machine.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for EGAt.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What EGAt means on a Electrolux oven
The EGAt error code on an Electrolux oven indicates that the appliance's control software cannot locate the GAS table for the specific model. The GAS table is a critical data set embedded in the appliance firmware that defines combustion parameters, burner timing sequences, gas valve control logic, and safety thresholds specific to that oven model. Without this table, the control board has no reference data to safely operate the gas system, so the machine halts completely to prevent unsafe operation.
This error is fundamentally a software or firmware issue, not a mechanical or component failure. It typically surfaces after a failed firmware update, a corrupted flash memory write, or when replacement control hardware is installed without the correct model-specific software package. In some cases, it can appear if the wrong firmware version is loaded onto the board, causing a model mismatch where the GAS table for the detected hardware configuration is absent from the installed software build.
Because the appliance stops operation entirely when EGAt is triggered, no gas cooking functions will be available until the issue is resolved. The prescribed resolution is to obtain the latest software version through the AGELUX platform and perform a firmware upgrade on the unit. Once the correct software containing the appropriate GAS table is successfully written to the control board, the error should clear and normal operation should resume.
Source: manufacturer service documentation.
Common causes of EGAt
- 01
Failed or incomplete firmware update
Wiring / connectionIf a previous software update was interrupted or did not complete successfully, the GAS table data may not have been written to the control board. This leaves the firmware in a partial state where model-specific combustion parameters are missing.
- 02
Incorrect firmware version installed
Wiring / connectionLoading a firmware build intended for a different model or variant can result in a missing GAS table, since the table in that build does not match the detected hardware configuration. Checking that the installed software version corresponds exactly to the unit's model number is a key diagnostic step.
- 03
Corrupted control board flash memory
Part replacementIf the control board's flash memory has degraded or suffered a corruption event, previously stored firmware including the GAS table may become unreadable. A firmware re-flash may resolve this, but persistent corruption can indicate the board itself needs replacement.
- 04
Replacement control board without model software
Wiring / connectionWhen a control board is replaced with a new or refurbished unit, it may not come pre-loaded with the model-specific GAS table. The correct firmware must be loaded via AGELUX before the board will operate properly.
Frequently asked questions about EGAt
What does EGAt mean on a Electrolux oven?
Can I fix the EGAt error myself on my Electrolux oven?
Is it safe to use my Electrolux oven when the EGAt code is showing?
Will resetting my Electrolux oven clear the EGAt error?
How much does it cost to repair an EGAt error on an Electrolux oven?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass