Electrolux Oven Error Code EtUb

Boiler over temperature (TBOI)

Boiler over temperature (TBOI) - stops cycle if boiler is used. Missing water in boiler, limestone accumulation, parameter BOT set too low.

First step from the service manual

Wait for boiler temperature to cool down; for Digit run cleaning with rinse and descale using 2 tabs C25; for Touch perform Boiler Maintenance procedure.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for EtUb.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What EtUb means on a Electrolux oven

The EtUb error code on an Electrolux oven indicates a boiler over-temperature condition, identified internally by the sensor designation TBOI (Temperature Boiler Input). When the boiler exceeds its safe operating temperature threshold, the appliance immediately halts the active cycle to prevent damage to internal components and potential safety hazards. This protective shutdown is triggered by the control board when the boiler temperature reading surpasses the configured BOT (Boiler Over Temperature) parameter value.

The most frequent root cause of this fault is insufficient water supply to the boiler. Without adequate water, the heating element rapidly raises the temperature of whatever residual liquid or scale remains, causing the sensor to register a runaway temperature spike. Limestone accumulation is another primary contributor: mineral deposits coat the heating element and boiler walls, insulating them from the water and causing localized overheating even when water is present. In some cases, the BOT parameter itself may be configured too low, causing the system to trip at temperatures that would otherwise be within a safe operating range.

Diagnostic approach depends on the model variant. For Digit-type models, the recommended starting point is allowing the boiler to cool completely, then running a full cleaning cycle using rinse and descale with two C25 tabs. For Touch-type models, the built-in Boiler Maintenance procedure should be performed instead. If descaling does not resolve the fault and the error returns, further investigation into water supply continuity, boiler sensor function, and BOT parameter settings is warranted.

Source: manufacturer service documentation.

Common causes of EtUb

  1. 01

    Missing or insufficient water in boiler

    Wiring / connection

    If the boiler does not have enough water during a cycle, the heating element overheats rapidly with no liquid to absorb the heat. Check that the water supply is connected and that the boiler is filling correctly before each cycle.

  2. 02

    Limestone or mineral scale accumulation

    Wiring / connection

    Hard water deposits build up on the boiler walls and heating element over time, reducing heat transfer efficiency and causing localized overheating. Running a descaling procedure with C25 tabs (two tabs for Digit models) is the primary remedy.

  3. 03

    BOT parameter set too low

    Wiring / connection

    The Boiler Over Temperature threshold (BOT parameter) in the control board settings may be configured below the actual operating temperature range, causing premature fault triggering. A technician would need to review and adjust this parameter through the service menu.

  4. 04

    Faulty boiler temperature sensor (TBOI)

    Part replacement

    If the TBOI sensor is malfunctioning, it may report falsely elevated temperatures even when the boiler is operating normally. This would require testing the sensor output and replacing it if readings are inaccurate.

  5. 05

    Blocked or failed water inlet to boiler

    Part replacement

    A clogged inlet valve or failed solenoid can prevent proper water flow into the boiler, effectively replicating a low-water condition. Inspect the inlet valve for blockages or electrical failure if descaling does not resolve the fault.

See the test procedure for each cause

Frequently asked questions about EtUb

What does EtUb mean on a Electrolux oven?
EtUb indicates a boiler over-temperature fault, triggered when the internal boiler sensor (TBOI) detects that the boiler has exceeded its safe temperature limit. The oven stops the active cycle automatically to prevent damage. Common causes include low water in the boiler, heavy limescale buildup, or a BOT parameter that is set too low.
How do I fix the EtUb error on my Electrolux oven?
Start by allowing the boiler to cool down completely before attempting any further action. If you have a Digit model, run a cleaning cycle using rinse and descale with two C25 tabs. If you have a Touch model, perform the Boiler Maintenance procedure through the appliance menu. If the error returns after descaling, the issue may require inspecting the water supply, the inlet valve, or the TBOI sensor.
Is it safe to keep using my Electrolux oven when EtUb is showing?
No, you should not attempt to continue using the oven while this error is active. The appliance has already halted the cycle as a safety measure to prevent damage from boiler overheating. Running additional cycles before resolving the root cause could damage the boiler, heating element, or surrounding components.
Will resetting the oven clear the EtUb error code?
A power reset may temporarily clear the error display, but the fault will return if the underlying cause has not been addressed. The boiler must first be allowed to cool, and the appropriate descaling or maintenance procedure must be completed. If the issue is a faulty sensor or misconfigured BOT parameter, those will need to be corrected by a technician.
How much does it cost to repair an Electrolux oven showing the EtUb error?
If the fix is simply a descaling procedure, costs are minimal, typically just the price of descaling tablets and your time. If a component like the boiler temperature sensor or water inlet valve needs replacement, repair costs including parts and labor could range from roughly $100 to $300 or more depending on your location and the specific parts required. A technician visit for diagnosis alone generally runs between $75 and $150.