mypros+
Error code reference

Electrolux Range Error Code 73

Power supply defect, Induction Housing Assembly / Right side cooking zones.

Power supply defect, Induction Housing Assembly / Right side cooking zones.

First step from the service manual

Test all cables & connections on Filter Circuit Board. Replace the Filter Circuit Board. Replace the Right Side Generator Circuit Board.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 73.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 73 means on a Electrolux range

Error code 73 on an Electrolux induction range indicates a power supply defect within the Induction Housing Assembly, specifically affecting the right side cooking zones. This fault is detected when the control system identifies an abnormal power supply condition in the circuitry that drives the right-side induction coils. The two primary circuit boards involved are the Filter Circuit Board, which conditions incoming AC power before distribution, and the Right Side Generator Circuit Board, which converts that conditioned power into the high-frequency current required to energize the induction coils.

The Filter Circuit Board plays a critical role in suppressing electrical noise and regulating voltage delivered to the generator boards. A failure here, whether from a failed capacitor, damaged trace, or loose connector, can produce unstable or defective power supply readings that trigger error 73. Wiring harnesses and connectors linking the Filter Circuit Board to the rest of the induction assembly are common failure points due to heat cycling and vibration over time.

If the Filter Circuit Board and its connections test satisfactory, the fault typically points to the Right Side Generator Circuit Board itself. This board contains power transistors and switching components that operate under high thermal stress. A shorted or open component on this board can disrupt the power supply to the right-side zones and cause the error. Diagnosis should proceed in order: inspect and test all cables and connections first, then evaluate the Filter Circuit Board, and finally assess the Right Side Generator Circuit Board for replacement.

Source: manufacturer service documentation.

Common causes of 73

  1. 01

    Loose or damaged wiring connections on the Filter Circuit Board

    Wiring / connection

    Heat cycling and vibration can loosen or corrode connectors between the Filter Circuit Board and the rest of the induction assembly. This is the first component to inspect, as a poor connection can mimic a board-level failure.

  2. 02

    Failed Filter Circuit Board

    Part replacement

    The Filter Circuit Board conditions incoming AC power for the induction generator boards. Internal component failure on this board, such as a damaged capacitor or burned trace, can produce a defective power supply signal and trigger error 73.

  3. 03

    Failed Right Side Generator Circuit Board

    Part replacement

    The Right Side Generator Circuit Board converts conditioned power into the high-frequency current needed for the right-side induction coils. Power transistors and switching components on this board are subject to high thermal stress and can fail, cutting power to those zones.

  4. 04

    Damaged wiring harness between circuit boards

    Part replacement

    The wiring harness connecting the Filter Circuit Board to the Right Side Generator Circuit Board can develop breaks, chafing, or melted insulation due to prolonged heat exposure. Visually inspect the full harness length for any visible damage.

See the test procedure for each cause

Frequently asked questions about 73

What does 73 mean on a Electrolux range?
Error code 73 on an Electrolux range signals a power supply defect in the Induction Housing Assembly, specifically affecting the right side cooking zones. The fault involves the circuitry that delivers and converts power to the right-side induction coils. The two key components involved are the Filter Circuit Board and the Right Side Generator Circuit Board. Until the fault is resolved, the right side burners may be non-functional.
Can I fix error code 73 on my Electrolux range myself?
Diagnosing error 73 requires testing cables, connectors, and circuit boards inside the range, which involves working near high-voltage components. A knowledgeable DIYer comfortable with appliance repair can inspect wiring connections as a first step, but replacing the Filter Circuit Board or Right Side Generator Circuit Board is a more involved repair. If you are not confident working with high-voltage induction components, a qualified appliance technician is recommended.
Is it safe to use my Electrolux range while error code 73 is showing?
When error 73 is active, the right side cooking zones are likely disabled or operating abnormally due to the detected power supply fault. Continuing to use the range in this condition is not advisable, as an underlying electrical fault in the induction circuitry could worsen or pose a risk. The left side zones may still function, but the range should be serviced before relying on it for regular use.
Will resetting my Electrolux range clear error code 73?
Resetting the range by cutting power at the breaker for a few minutes may temporarily clear error 73, but the code will return if the underlying fault in the power supply circuit is still present. The root cause, whether a loose connection, a failed Filter Circuit Board, or a failed Right Side Generator Circuit Board, must be identified and corrected for the error to be permanently resolved.
How much does it cost to repair error code 73 on an Electrolux range?
Repair costs for error 73 vary depending on which component has failed. If the issue is limited to a loose or damaged wiring connection, labor costs alone may apply, typically in the range of $80 to $150. Replacing the Filter Circuit Board or the Right Side Generator Circuit Board will add parts costs on top of labor, which can bring the total repair estimate to roughly $200 to $500 or more depending on parts pricing and local labor rates.

78,000+ service manuals · 160,000+ error codes · 55+ brands