What AS means on a Frigidaire air conditioner

The AS error code on a Frigidaire air conditioner indicates that the control board has detected a failure in one of the unit's internal sensors. These sensors monitor critical operating conditions such as ambient temperature, evaporator temperature, or condenser temperature. When the control board receives a signal outside of the expected range, or no signal at all from the sensor circuit, it triggers the AS code and typically halts normal operation to prevent potential damage.

For homeowners, this means one of the small electronic components responsible for reading temperatures inside your air conditioner has stopped working correctly. The unit cannot accurately track its own operating conditions without a functioning sensor, which is why it stops and displays the error rather than continuing to run blind. The sensor itself may have failed internally, or the wiring connecting it to the control board may be damaged or disconnected.

Because diagnosing which specific sensor has failed and verifying the associated wiring requires test equipment and access to internal components, Frigidaire directs users to contact an Authorized Frigidaire Service Center as the first step. Attempting to open the unit without proper training can void warranties and cause further damage.

Source: manufacturer service documentation.

Common causes of AS

  1. 01

    Failed temperature sensor

    Part replacement

    The thermistor or temperature sensor itself has malfunctioned internally, producing an out-of-range resistance value or no signal. This is the most direct cause of the AS code and requires sensor replacement.

  2. 02

    Damaged or disconnected sensor wiring

    Wiring / connection

    The wiring harness between the sensor and the control board may be broken, corroded, or unplugged, causing the control board to read no signal. This can sometimes be resolved by reseating the connector but may require a wiring repair.

  3. 03

    Corroded or oxidized sensor connector

    Wiring / connection

    Moisture exposure inside the unit can cause the sensor connector pins to corrode, increasing resistance in the circuit and causing the control board to misread the sensor signal as a failure.

  4. 04

    Faulty control board

    Part replacement

    If the sensor and its wiring test within normal specifications, the control board itself may be misinterpreting the sensor signal due to an internal fault. Board replacement is required in this scenario.

See the test procedure for each cause

Frequently asked questions about AS

What does the AS error code mean on a Frigidaire air conditioner?
The AS code means the control board has detected a sensor failure. The sensor involved monitors temperature conditions inside the unit, such as evaporator or ambient temperature. When the sensor sends an out-of-range or absent signal, the unit displays AS and stops normal operation to protect itself from running without accurate temperature data.
How do I fix the AS error code on my Frigidaire air conditioner?
Frigidaire's first recommended step for the AS code is to contact an Authorized Frigidaire Service Center. A technician will use a multimeter to test the resistance of the temperature sensor and check continuity through the wiring harness. If the sensor is out of spec, it gets replaced. If the wiring is damaged or a connector is corroded, those are repaired or replaced. In rare cases the control board itself is the fault.
Can I still use my Frigidaire air conditioner when it shows the AS error code?
Operating the unit while the AS code is active is not recommended. The air conditioner relies on sensor data to regulate cooling cycles and prevent conditions like freezing or overheating. Running it without a functioning sensor can lead to compressor damage or reduced efficiency. Power the unit off and schedule service before resuming use.
How much does it cost to repair the AS error code on a Frigidaire air conditioner?
Repair cost depends on which component has failed. A temperature sensor replacement is typically a low-cost part, often under $20, but labor from an authorized technician adds to the total. If the control board is the fault, parts alone can range from $50 to $150 or more depending on the model. Getting a diagnostic visit from an Authorized Frigidaire Service Center will give you an accurate estimate for your specific unit.
Will unplugging my Frigidaire air conditioner clear the AS error code?
Unplugging the unit and restoring power may temporarily clear the display, but if the underlying sensor or wiring fault still exists, the AS code will return once the control board runs its diagnostics again. A power reset is not a fix for a failed sensor. The root cause needs to be diagnosed and repaired for the error to stay cleared.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass