Frigidaire Air Conditioner Error Code CS
Condenser thermostat sensor has failed (heat pump models only); displays for 1 second every 10 seconds.
Condenser thermostat sensor has failed (heat pump models only); displays for 1 second every 10 seconds.
Get the full diagnostic procedure for CS.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What CS means on a Frigidaire air conditioner
The CS error code on Frigidaire heat pump models indicates a failure in the condenser thermostat sensor. This sensor is a thermistor-based component mounted on the condenser coil assembly that monitors refrigerant-side temperatures during heating and cooling cycles. The control board uses this data to regulate compressor operation, protect against overcooling or overheating of the condenser, and manage defrost cycling in heat pump mode. When the board detects that the sensor's signal is outside of its expected range, it triggers the CS fault.
The distinctive display behavior, showing the code for 1 second out of every 10 seconds, is a pulsed alert pattern. This is designed to draw attention without completely interrupting the unit's status display. It does not necessarily mean the unit has shut down entirely, but the control system is operating with compromised or missing temperature feedback from the condenser side.
Common failure modes include an open or shorted thermistor, damaged wiring between the sensor and the control board, or a corroded connector at either end of the sensor harness. Because this code applies exclusively to heat pump models, technicians should focus diagnostics on the condenser thermostat sensor circuit specific to heat pump wiring configurations rather than standard cooling-only sensor paths.
Source: manufacturer service documentation.
Common causes of CS
- 01
Failed condenser thermistor
Part replacementThe thermistor itself may have developed an open or short circuit, causing it to send a signal outside the acceptable range to the control board. Resistance testing of the sensor at the connector will reveal whether it has failed.
- 02
Damaged sensor wiring harness
Part replacementThe wiring between the condenser thermostat sensor and the control board can become pinched, cut, or chafed over time, especially near sharp metal edges on the cabinet. Visually inspect the full wire run and check for continuity.
- 03
Corroded or loose connector
Wiring / connectionMoisture intrusion at the sensor harness connector can cause corrosion on the terminals, leading to an intermittent or lost signal. Inspect both the sensor-side and board-side connectors for green or white oxidation and ensure a secure fit.
- 04
Control board fault
Part replacementIf the sensor and all wiring test within spec, the control board's sensor input circuit may have failed. This is less common but should be considered after ruling out the sensor and wiring.
Frequently asked questions about CS
What does CS mean on a Frigidaire air_conditioner?
Can I fix the CS error code myself?
Is it safe to keep running my Frigidaire heat pump with a CS error?
How much does it cost to repair a CS error on a Frigidaire heat pump?
Will resetting the unit clear the CS error code?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass