GE Oven Error Code F2

Double Line Break Relay is ON in a non-cooking/clean mode, or failed component on control

Double Line Break Relay is ON in a non-cooking/clean mode, or failed component on control. Also indicates oven over temperature condition (door unlocked oven exceeded 600°F, door locked oven exceeded 925°F for ERCII/RS4800/RS5800, or 960°F for TO7). Also triggered by open thermal switch or both lock switches 1 & 2 closed at the same time.

First step from the service manual

For ERCII with key pads built in: repeat mode of operation, if failure re-occurs replace control. For separate key pads: push CLEAR/OFF, disconnect ribbon cable and wait 32 seconds to see if code re-occurs. For over temp: look for welded relay contacts on bake or broil relays. If over temp did not occur: look for high resistance connection in sensor circuit, check thermal switch, check fan operation.