Error code reference

GE Oven Error Codes

88 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
Auto Cook DelayOven will not accept Auto Cook Code because the oven cavity is still hot from previous…C1Communication Fail with Upper Relay Board.C2Communication fail with upper temperature encoder.C3Communication fail with upper mode encoder.C4Communication Fail with Lower Relay Board.C5Communication fail with lower temperature encoder.C6Communication fail with lower mode encoder.CXCommunication error (general).DOORIndicates the oven door is not closed when self-clean cycle is selected, or the door is…EEEEError displayed when an invalid time entry is made (e.g., impossible clock time like…ENTERING SALES MODEDuring power-up, L1-L2 is between 90VAC and 150VAC and L1-N is between 90VAC and 150VAC…ERRA temperature was set outside the allowable range of 170°F-550°F.ERRORError displayed when temperature is set below 80°F or above 199°F during Temp Cook, or…FFunction error code indicated by 'F' followed by a number or letter flashing in the…F– and a number or letterFunction error code indicating a control or component malfunction.F0Oven exceeded 590°F with door in unlocked position or exceeded 990°F with door locked, or…F1Oven cavity thermistor openF2Double Line Break Relay is ON in a non-cooking/clean mode, or failed component on controlF20Thermal runawayF21Thermal runawayF22Lower oven temperature climbs above the Error Unlock Temperature while the latch input is…F23Lower oven temperature climbs above the Error Lock Temperature while the latch input is…F3Open sensor or open sensor circuit; sensor lead shorted to ground at ERC; or intermittent…F30Upper oven sensor circuit fault related to oven sensor resistance thresholds.F31Upper oven sensor circuit fault related to oven sensor resistance thresholds.F32Lower oven sensor circuit fault related to oven sensor resistance thresholds.F33Lower oven sensor circuit fault related to oven sensor resistance thresholds.F34Sensor calibration CRC failure or difference between RTD temperature and fine tune…F35Lower oven calibration CRC fails or difference between RTD temperature and fine tune…F4Open or shorted oven temperature sensor or sensor circuit (intermittent sensor or sensor…F40Meat probe faultF41Meat probe faultF5Control sensor circuit supervisor errorF6High cavity temperature detected during microwave oven cooking.F60Loss of communications to upper machine control (Machine Control only).F61Communication loss to the Upper Temp Encoder.F62Communication loss to the Upper Mode Encoder.F63Loss of communications to lower machine control (Machine Control only).F66Loss of communications to user interface (Machine Control only).F7Double Line Break Relay is ON in a non-cooking/clean mode or failed component on control.F70Key panel faultF71ERC detects continuous keypanel press (T012 tactile) or glass touch input fault (T012…F72Glass touch input fault (T012 glass touch units).F73Glass touch input fault (T012 glass touch units).F74Glass touch input fault (T012 glass touch units).F75Glass touch input fault (T012 glass touch units).F76Glass touch input fault (T012 glass touch units).F77Glass touch input fault (T012 glass touch units).F78Glass touch input fault (T012 glass touch units).F79Glass touch input fault (T012 glass touch units).F7AMachine control glass touch detects a stuck key other than START and Clear.F7BMachine control glass touch detects a stuck START key.F7CUpper CLEAR key stuck condition (Machine Control glass touch).F7dLower CLEAR key stuck condition (Machine Control glass touch).F7EGlass touch communication failure (Machine Control).F7FGlass touch Cyclic Redundancy Check (CRC) failureF8Oven Door switch is in the C to NC position or Lock Motor does not turn.F80Internal electronic problem in the upper machine control or T012 ERCF81Internal electronic problem in the lower machine control or T012 ERCF82User Interface data failure (CRC)F9Clean FAD (Fan Apparency Device) thermal cutoff has opened, indicating excessive…F90Door latchF91Upper oven door becomes unlocked while it is expected to be locked (during self-clean and…F92Upper/single oven door latch switch circuit fault.F93Lower oven door latch switch circuit fault.F94Lower oven door latch switch circuit fault.F95Lower oven door latch switch circuit fault.F96The speed of the upper cooling fan is below the minimum fan speed parameter for 30…F97The speed of the lower cooling fan is below the minimum fan speed parameter for 30…F98The speed of the upper cooling fan is above the minimum fan speed parameter for 30…F99The speed of the lower cooling fan is above the minimum fan speed parameter for 30…FCLook for welded relay contacts (heating elements on in off mode); look for open thermal…FdShorted meat probe (Profile/Convection models only).FFComponent failure within ERC affecting temperature processing circuits.HOTOven temperature is above 150°F, preventing proofing mode from operating.LOCControl lockout is active; touch pads are locked and cannot be activated.LOC ONControl lockout is active; all touch pads are disabled and cannot be activated when…LOCKLock switch circuit open (flashing on display).LOCK DOORSelf-clean cycle has been selected but the oven door is not closed.LOW POWERAfter power-up, L1-L2 voltage is below 150VAC indicating insufficient line voltage for…PFPower Failure indicator appears on display when electrical power to the unit has been…PROBDisplayed when temperature probe is accidentally left plugged into the oven receptacle…PROBEProbe not inserted properly into oven receptacle or food, or Temp Cook/Hold or Auto Roast…RESETAppears in the upper display after power is first connected or after a power failure…SENSE 120V ENTERING SALES MODEDuring power-up, L1-L2 is between 90VAC and 150VAC and L1-N is between 90VAC and 150VAC…SENSOR ERRORFood amount or type placed in the oven does not match the program that was set, or steam…SUPPLY MISWIREDPower monitor error indicating supply is miswiredSUPPLY OPEN NEUTRALPower monitor detects L1-N voltage below 90VAC during power-up, indicating an open…

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for all brands and Max diagnostics, with 70 Max messages a day. Plus applicable tax.