GE Dryer Error Codes

160 error codes documented with diagnostic procedures.

Have your model number? Get codes specific to your unit.
000No errors present.001Inlet Thermistor Short002Outlet Thermistor Short003Inlet Thermistor Open004Outlet Thermistor Open005EEPROM error006Stuck button007Miss-wire008Door latch stuck009Drum motor error00DDoor signal stuck1Lock Monitor10Mode Shift Feedback Monitor11Blocked vent12Redundant Flood Condition13Redundant Lid Unlocked14Door latch pulsing error15Water Temp Sensor Invalid16UI-MC Heartbeat Timeout17UI-MC Event Sequence Communication Overrun18Drain Pump Clearing algorithm failed19UI State Timeout1nIgniter turns ON during Field Service Mode test (gas dryer only).2Lid Monitor2 (Critical)Fill time out (critical failure)20Critical Flood Level by Gallons22Out of Balance (OOB) during Dry Load Sense23Critical Lid Lock Failure24Lid Logic Failure25Pressure Sensor Dropout26Out of Balance (OOB) Ended Final Spin27Water Accessibility28Options Knobs Feedback Invalid29Suds Lock Abatement Failure2nUltra Care relay turns ON during Field Service Mode test (gas dryer only).3Locked Rotor Monitor30Stuck Button Fault31Out of Balance (OOB) Fallback In Final Spin32Critical Lid Lock Failure: Can't Unlock Lid3E1Motor relay open error triggered when the motor state is running but control detects high…3E2Motor relay stuck error triggered when the motor state is stop but control detects the…4Lid switch failure5Mode Shifter5EDrain fail error triggered when water overflow is detected 3 consecutive times.6Critical Flood Level by Pressure7Miss Wire8Pressure Sensor Loss88Countdown display board self-test indicator shown for 2-3 seconds upon coin box timer…9Lid Switch RedundancybE2Button error triggered when any key is continuously pressed for more than 30 seconds.Blocked AirflowBlower speed is detected to be at or above 3000 RPM for over 30 seconds, indicating…BLOCKED MOTORMotor is blocked and unable to rotate.Blower not speeding upDuring initial warm-up, the blower failed to reach the minimum speed necessary to turn on…CLgDuct/vent blockage detected; dryer will continue to operate but display may appear…d0Door is open (door status check in Field Service Mode).dCDoor is closed (door status check in Field Service Mode).dEDoor fail error triggered when door interrupt voltage is continuously low level for more…Door Switch Stuck ClosedAn attempt has been made to start a cycle after 3 or more consecutive cycles without the…Door Switch Stuck OpenDryer did not detect the door was closed within 5 minutes of displaying 'Please close the…E0No error detected in the thermistor circuit.E00No faults in the log-displayed in Consumer Fault Code Mode when there are no active…E01Inlet thermistor shortE02Outlet thermistor shortE03Inlet thermistor open-readings exceed the maximum threshold (4.8V) for 5 minutes.E04Outlet thermistor openE05EEPROM CRC fault-bad CRC (Cyclic Redundancy Check) detected when reading a page from…E06Different EEPROM detected; UI type stored in EEPROM does not match physical UI present.E07Mis-wired-L1 and N are mis-wired (L1 and N AC input > 162V).E08Door latch stuckE09Door signal stuckE1Inlet Thermistor Short-the inlet thermistor readings exceed the minimum threshold (0.2V)…E10General EEPROM faultE101EEPROM improper read or write on the power board.E11Heating fault-within 15 minutes of the heating process, the temperature rise has not…E12Communication fault-three communication failures between main and user interface boards.E14Stuck keys detected on control panel.E16Communication failure between the machine control and the UI control (LIN Comm Fail).E17VFD communication errorE18Stuck button/key detected on the control panel.E2Outlet Thermistor Short-the outlet thermistor readings exceed the minimum threshold…E24Control NTC short circuitE25Control NTC open circuitE3User interface keyswitch or software mismatch between console electronics and machine…E4Specific failure associated with the inlet control thermistor.E4AProgram timeout faultE5EEPROM CRC fault-bad CRC (Cyclic Redundancy Check) detected when reading a page from…E50EEPROM failure (electronic control error).E5BHeater fault (no heating)E6Stuck button-a button has been depressed for 1 minute and is logged as stuck.E60Door switch has not opened during the last 3 consecutive completed cycles.E61L2 and N incorrectly wired (AC input too high)E62Control board input error; AC line frequency detection error and low input voltage.E68Key (button) stuck faultE7Mis-wired-L1 and N are mis-wired (L1 and N AC input > 162V).E8Door latch stuck-five cycles are run and the door signal in the hardware door switch…E80L2 and N miswiredE81Model selector connector not detected on the power board.E8CThe safety (high limit) thermostat has tripped too many times within a certain period of…E9Door signal stuck-five cycles are run and the door signal in the hardware door switch…EAFWatchdog resetEEEEPROM errorELIdentifies the dryer type as Electric during Field Service Mode.F01Inlet thermistor short circuit.F010Empty drum detected.F011Dry load detected.F02Outlet thermistor short circuit.F03Inlet thermistor open circuit.F04Outlet thermistor open circuit.F05EEPROM Error.F06Stuck buttonF07Mis-wireF08Door switch stuck closedF09Long dry timesF10Empty drum detected.F11Dry load detected.FdField Service Diagnostics mode has been entered (initial display).FEPower frequency errorFILL TIME OUTCritical failureFILLING TIMEOUTWasher has exceeded the allowed time to fill with water.Flame Detector / IgnitorUsing the feedback signal from the flame detector, the control has detected the flame…Flash ROM EEPROMChecksum errors found; data is not being stored correctly in controlGAIdentifies the dryer type as Gas during Field Service Mode.Gas Setup FailedThe control determined the heat level output does not match the model connector plug…H1Heater 1 (outer coil) turns ON during Field Service Mode test.H2Heater 2 (inner coil) turns ON (heater 1 OFF) during Field Service Mode test.HEHeating error triggered when heating temperature exceeds 185°F for more than 10 seconds…HE4Heating error (filter check) triggered when clean lint filter condition is detected 3…HeaterAfter each thermistor has been checked and no heating is detected by either thermistor…Inlet ThermistorInlet thermistor reading is out of expected range; dryer will default to controlling…Keypanel MembraneControl sensed a keypanel membrane pad pressed for longer than 30 seconds; unit will…LCD Display TouchscreenControl sensed an LCD display touchscreen input for longer than 30 seconds; unit will…LID LOCK BROKENCritical failureLID LOCK FAILURECritical failureLID LOCK NOT OPEN / CLOSELid lock mechanism is unable to open or close properly.LID SWITCHLid switch failure detected.LID SWITCH FAILURECritical failureLOOSE BELTDrive belt is loose or has lost proper tension.Model Connector FailedThe control determined the model connector plug is missing on a gas dryer or a connector…Moisture SensorControl has determined the moisture sensor rods are shorted; dryer will operate using…NO SPEEDMotor speed signal not detected.odOver dry error triggered when the dry and cooling process exceeds 240 minutes, indicating…Outlet ThermistorOutlet thermistor reading is out of expected rangeOVERFLOWWater level in the tub has exceeded the maximum allowable level.PFPower failure occurred while the dryer was running.PSHigh voltage error.PUMP TIMEOUTDrain pump has exceeded the allowed time to pump out water.REPLACE CONTROL BOARDControl board has an unrecoverable internal failure requiring replacement (3 separate…S0Sensor rods open circuit, normal condition (capacitor charged properly).SEMoisture sensor error display during diagnostic test.Serial Washer and Dryer ConnectionDryer has not received a proper response from the washer after 3 attempts; serial…SnMotor switches ON and is running during Field Service Mode test.SSSensor rod capacitor discharged properly, indicating rods and circuit are functioning…t0Thermistor opentEThermistor outlet error-the outlet thermistor value is outside the valid range (00 to…tE1Thermistor open circuit detected.tE2Inlet thermistor errortE4Outlet thermistor errorTHERMISTORThermistor sensor fault detected.tOThermistor open circuit detected.tSThermistor short

Get the full diagnostic procedure for any code

Step-by-step tests, expected values, wiring diagram references, and verified part numbers.

Get Started $9.95 3-day pass

$29/month for unlimited access to all brands and Max AI diagnostics.

Common questions

How do I find the error code on my GE Dryer?
Most GE dryers show the code directly on the control panel display. If your model has no display, it can be read by entering diagnostic mode with the key sequence for your model. The full procedures include model-specific instructions for reading codes.
Are these codes specific to my model?
The codes here apply broadly to GE dryers. Meanings and diagnostic steps can vary by model and production year, so enter your model number for model-specific information and procedures.
What do I do if my code is not listed?
Some codes are model-specific or only appear in diagnostic mode. Enter your model number to get codes specific to your unit, or contact us. We update the database continuously from manufacturer service documentation.
How much does it cost to access the full diagnostic procedures?
A 3-day pass is $9.95 one-time and gives full access to all brands, codes, and procedures. Monthly access is $29/month with unlimited access to everything including Max AI diagnostics.