GE Dryer Error Codes

161 error codes for GE dryer models. Each links to the full diagnostic procedure from the service manual.

MyPros+ Max

Get the full diagnostic procedure for any GE dryer error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

17UI-MC Event Sequence Communication Overrun18Drain Pump Clearing algorithm failed19UI State Timeout1nIgniter turns ON during Field Service Mode test (gas dryer only).2Lid Monitor2 (Critical)Fill time out (critical failure)20Critical Flood Level by Gallons22Out of Balance (OOB) during Dry Load Sense23Critical Lid Lock Failure24Lid Logic Failure25Pressure Sensor Dropout26Out of Balance (OOB) Ended Final Spin27Water Accessibility28Options Knobs Feedback Invalid29Suds Lock Abatement Failure2nUltra Care relay turns ON during Field Service Mode test (gas dryer only).3Locked Rotor Monitor30Stuck Button Fault31Out of Balance (OOB) Fallback In Final Spin32Critical Lid Lock Failure: Can't Unlock Lid3E1Motor relay open error triggered when the motor state is running but control…3E2Motor relay stuck error triggered when the motor state is stop but control…4Lid switch failure5Mode Shifter5EDrain fail error triggered when water overflow is detected 3 consecutive times.6Critical Flood Level by Pressure7Miss Wire8Pressure Sensor Loss88Countdown display board self-test indicator shown for 2-3 seconds upon coin box…9Lid Switch RedundancybE2Button error triggered when any key is continuously pressed for more than 30…Blocked AirflowBlower speed is detected to be at or above 3000 RPM for over 30 seconds…BLOCKED MOTORMotor is blocked and unable to rotate.Blower not speeding upDuring initial warm-up, the blower failed to reach the minimum speed necessary…CLgDuct/vent blockage detected; dryer will continue to operate but display may…d0Door is open (door status check in Field Service Mode).dCDoor is closed (door status check in Field Service Mode).dEDoor fail error triggered when door interrupt voltage is continuously low level…Door Switch Stuck ClosedAn attempt has been made to start a cycle after 3 or more consecutive cycles…Door Switch Stuck OpenDryer did not detect the door was closed within 5 minutes of displaying 'Please…E0No error detected in the thermistor circuit.E00No faults in the logE01Inlet thermistor shortE02Outlet thermistor shortE03Inlet thermistor openE04Outlet thermistor openE05EEPROM CRC faultE06Different EEPROM detected; UI type stored in EEPROM does not match physical UI…E07Mis-wiredE08Door latch stuckE09Door signal stuckE1Inlet Thermistor ShortE10General EEPROM faultE101EEPROM improper read or write on the power board.E11Heating faultE12Communication faultE14Stuck keys detected on control panel.E16Communication failure between the machine control and the UI control (LIN Comm…E17VFD communication errorE18Stuck button/key detected on the control panel.E2Outlet Thermistor ShortE24Control NTC short circuitE25Control NTC open circuitE3User interface keyswitch or software mismatch between console electronics and…E4Specific failure associated with the inlet control thermistor.E4AProgram timeout faultE5EEPROM CRC faultE50EEPROM failure (electronic control error).E5BHeater fault (no heating)E6Stuck buttonE60Door switch has not opened during the last 3 consecutive completed cycles.E61L2 and N incorrectly wired (AC input too high)E62Control board input error; AC line frequency detection error and low input…E68Key (button) stuck faultE7Mis-wiredE8Door latch stuckE80L2 and N miswiredE81Model selector connector not detected on the power board.E8CThe safety (high limit) thermostat has tripped too many times within a certain…E9Door signal stuckEAFWatchdog resetEEEEPROM errorELIdentifies the dryer type as Electric during Field Service Mode.F01Inlet thermistor short circuit.F010Empty drum detected.F011Dry load detected.F02Outlet thermistor short circuit.F03Inlet thermistor open circuit.F04Outlet thermistor open circuit.F05EEPROM Error.F06Stuck buttonF07Mis-wireF08Door switch stuck closedF09Long dry timesF10Empty drum detected.F11Dry load detected.FdField Service Diagnostics mode has been entered (initial display).FEPower frequency errorFILL TIME OUTCritical failureFILLING TIMEOUTWasher has exceeded the allowed time to fill with water.Flame Detector / IgnitorUsing the feedback signal from the flame detector, the control has detected the…Flash ROM EEPROMChecksum errors found; data is not being stored correctly in controlGAIdentifies the dryer type as Gas during Field Service Mode.Gas Setup FailedThe control determined the heat level output does not match the model connector…H1Heater 1 (outer coil) turns ON during Field Service Mode test.H2Heater 2 (inner coil) turns ON (heater 1 OFF) during Field Service Mode test.HEHeating error triggered when heating temperature exceeds 185°F for more than 10…HE4Heating error (filter check) triggered when clean lint filter condition is…HeaterAfter each thermistor has been checked and no heating is detected by either…Inlet ThermistorInlet thermistor reading is out of expected range; dryer will default to…Keypanel MembraneControl sensed a keypanel membrane pad pressed for longer than 30 seconds; unit…LCD Display TouchscreenControl sensed an LCD display touchscreen input for longer than 30 seconds…LID LOCK BROKENCritical failureLID LOCK FAILURECritical failureLID LOCK NOT OPEN / CLOSELid lock mechanism is unable to open or close properly.LID SWITCHLid switch failure detected.LID SWITCH FAILURECritical failureLOOSE BELTDrive belt is loose or has lost proper tension.Model Connector FailedThe control determined the model connector plug is missing on a gas dryer or a…Moisture SensorControl has determined the moisture sensor rods are shorted; dryer will operate…NO SPEEDMotor speed signal not detected.odOver dry error triggered when the dry and cooling process exceeds 240 minutes…Outlet ThermistorOutlet thermistor reading is out of expected rangeOVERFLOWWater level in the tub has exceeded the maximum allowable level.PFPower failure occurred while the dryer was running.PSHigh voltage error.PUMP TIMEOUTDrain pump has exceeded the allowed time to pump out water.REPLACE CONTROL BOARDControl board has an unrecoverable internal failure requiring replacement (3…S0Sensor rods open circuit, normal condition (capacitor charged properly).SEMoisture sensor error display during diagnostic test.Serial Washer and Dryer ConnectionDryer has not received a proper response from the washer after 3 attempts…SnMotor switches ON and is running during Field Service Mode test.SSSensor rod capacitor discharged properly, indicating rods and circuit are…t0Thermistor opentEThermistor outlet errortE1Thermistor open circuit detected.tE2Inlet thermistor errortE4Outlet thermistor errorTHERMISTORThermistor sensor fault detected.tOThermistor open circuit detected.tSThermistor short

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started