GE Dryer Error Code 008

Door latch stuck

Door latch stuck - If five cycles are run and the door signal in the hardware door switch detection circuit has not gone open for five cycles, this error is set; can be door switch failure, harness failure, board failure or software protection.

First step from the service manual

Open door and if this error is cleared, it is a software protection. If error is not cleared, check door switch, control board or harness.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 008.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 008 means on a GE dryer

Error code 008 on a GE dryer indicates that the door latch circuit is stuck in the closed position. The control board monitors the hardware door switch detection circuit across multiple cycles, and if the door signal fails to register an open state for five consecutive cycles, this error is triggered. In normal operation, the door switch should toggle between open and closed states as the door is opened and closed between cycles. When the board never sees that open signal after five full cycles, it flags this fault.

The error can originate from several points in the circuit. The door switch itself is the most mechanical component in this circuit and is subject to wear, debris buildup, or contact failure that causes it to remain in a closed or shorted state. The wiring harness connecting the door switch to the control board can suffer from pinched wires, broken connectors, or corrosion that produces a continuous false closed signal. If the switch and harness both check out, the control board itself may be misreading the circuit input.

The first diagnostic step is straightforward: open the dryer door and observe whether the error clears. If opening the door causes the error to disappear, the hardware is functioning correctly and the fault was a software protection trigger, meaning the board temporarily lost track of door state through a logic issue. If the error persists with the door open, a physical component failure is present in the switch, harness, or board, and further electrical testing is required.

Source: manufacturer service documentation.

Common causes of 008

  1. 01

    Door switch failure

    Part replacement

    The mechanical door switch can wear out or have contacts that stick in the closed position, preventing the circuit from ever signaling an open door. Inspect the switch for physical damage and test it for continuity when the door is both open and closed.

  2. 02

    Software protection trigger

    Wiring / connection

    If opening the door clears the error immediately, no hardware has failed. The control board's software flagged the fault as a protective measure, possibly due to a momentary signal disruption across five cycles.

  3. 03

    Wiring harness fault

    Part replacement

    A pinched, corroded, or broken wire in the harness between the door switch and the control board can create a constant closed signal. Inspect the harness along its full path for visible damage and check connector terminals for corrosion or poor seating.

  4. 04

    Control board failure

    Part replacement

    If the door switch and harness both test correctly, the control board may be misinterpreting or failing to read the door switch input signal. This is typically diagnosed after all other components have been ruled out.

See the test procedure for each cause

Frequently asked questions about 008

What does 008 mean on a GE dryer?
Error code 008 on a GE dryer means the control board detected that the door signal in the hardware door switch detection circuit never registered an open state across five consecutive cycles. The board interprets this as the door latch being stuck closed. The fault can be caused by a failed door switch, a wiring harness problem, a faulty control board, or a software protection event.
How do I fix error code 008 on my GE dryer?
Start by opening the dryer door and checking whether the error clears. If it does, the issue was a software protection trigger and no parts may be needed. If the error remains with the door open, inspect the door switch for damage and test it for proper continuity, then check the wiring harness for broken wires or corroded connectors. If both check out, the control board may need to be replaced.
Will resetting my GE dryer clear error code 008?
A power reset may temporarily clear the code, but if a hardware fault is present in the door switch or wiring harness, the error will return after five more cycles without a proper door open signal. If the error clears simply by opening the door during an active session, it may have been a one-time software protection event and no reset beyond that is needed.
Is it safe to keep using my GE dryer when error code 008 is displayed?
Operating the dryer with an unresolved door switch fault is not recommended. The door switch is part of the safety circuit that ensures the drum does not spin while the door is open. A faulty switch could prevent the dryer from stopping when the door is opened, which presents a safety risk. Diagnose and resolve the fault before continuing regular use.
How much does it cost to fix a GE dryer showing error code 008?
If the issue is only a software protection trigger that clears when the door is opened, there is no parts cost. A replacement door switch typically costs in the range of $15 to $50 for the part alone. A new control board is considerably more expensive, generally ranging from $100 to $300 or more depending on the model. Professional labor costs will add to any parts expense.