GE Dryer Error Code 008
Door latch stuck
Door latch stuck - If five cycles are run and the door signal in the hardware door switch detection circuit has not gone open for five cycles, this error is set; can be door switch failure, harness failure, board failure or software protection.
First step from the service manual
Open door and if this error is cleared, it is a software protection. If error is not cleared, check door switch, control board or harness.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for 008.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What 008 means on a GE dryer
Error code 008 on a GE dryer indicates that the door latch circuit is stuck in the closed position. The control board monitors the hardware door switch detection circuit across multiple cycles, and if the door signal fails to register an open state for five consecutive cycles, this error is triggered. In normal operation, the door switch should toggle between open and closed states as the door is opened and closed between cycles. When the board never sees that open signal after five full cycles, it flags this fault.
The error can originate from several points in the circuit. The door switch itself is the most mechanical component in this circuit and is subject to wear, debris buildup, or contact failure that causes it to remain in a closed or shorted state. The wiring harness connecting the door switch to the control board can suffer from pinched wires, broken connectors, or corrosion that produces a continuous false closed signal. If the switch and harness both check out, the control board itself may be misreading the circuit input.
The first diagnostic step is straightforward: open the dryer door and observe whether the error clears. If opening the door causes the error to disappear, the hardware is functioning correctly and the fault was a software protection trigger, meaning the board temporarily lost track of door state through a logic issue. If the error persists with the door open, a physical component failure is present in the switch, harness, or board, and further electrical testing is required.
Source: manufacturer service documentation.
Common causes of 008
- 01
Door switch failure
Part replacementThe mechanical door switch can wear out or have contacts that stick in the closed position, preventing the circuit from ever signaling an open door. Inspect the switch for physical damage and test it for continuity when the door is both open and closed.
- 02
Software protection trigger
Wiring / connectionIf opening the door clears the error immediately, no hardware has failed. The control board's software flagged the fault as a protective measure, possibly due to a momentary signal disruption across five cycles.
- 03
Wiring harness fault
Part replacementA pinched, corroded, or broken wire in the harness between the door switch and the control board can create a constant closed signal. Inspect the harness along its full path for visible damage and check connector terminals for corrosion or poor seating.
- 04
Control board failure
Part replacementIf the door switch and harness both test correctly, the control board may be misinterpreting or failing to read the door switch input signal. This is typically diagnosed after all other components have been ruled out.
Frequently asked questions about 008
What does 008 mean on a GE dryer?
How do I fix error code 008 on my GE dryer?
Will resetting my GE dryer clear error code 008?
Is it safe to keep using my GE dryer when error code 008 is displayed?
How much does it cost to fix a GE dryer showing error code 008?
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass