mypros+

GE Refrigerator Error Codes

574 error codes for GE refrigerator models. Each links to the full diagnostic procedure from the service manual.

MyPros+ Max

Get the full diagnostic procedure for any GE refrigerator error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

0101Freezer (FZ) fan feedback present when fan is off.0102Freezer (FZ) fan cannot reach target RPM.0103Condenser fan feedback missing when fan is running.0104Condenser fan feedback is present when fan is off.0106Refrigerator (FF) fan feedback missing when fan is running.0107Refrigerator (FF) fan feedback present when fan is off.0108Refrigerator (FF) fan cannot reach target RPM.0109Ice box fan feedback missing when the fan is running.0110Ice Box Fan Feedback Present when Fan is off.0111Ice Box Fan cannot reach target speed.0112Deli pan fan feedback missing when the fan is running.0114Deli Pan Fan cannot reach target speed.0115Odor remover fan feedback missing when the fan is running.0116Odor remover fan feedback present when fan is off.0117Odor remover fan cannot reach target speed.02Refrigerator sensor error0200FZ defrost heater timed out, 45-minutes of defrost on time (check FZ evaporator…0201Refrigerator defrost heater on for max time (check FF evap thermistor fault…0202FF Defrost Heater timed out (check FF Evap thermistor fault code 0006)0203Five consecutive refrigerator abnormal defrosts.03Refrigerator defrost sensor error0300Temperature satisfied > 3 hours (no compressor operation).0301Temperatures satisfied for more than 4 hours with no compressor operation0302FF temperature below freezing.0303FF temperature exceeds 20°F over setpoint, 1-hour post defrost or door opening.0304FZ temperature exceeds 20°F over setpoint, 1-hour post defrost or door opening.0305N/A0306N/A0307Damper driver fault (this fault code not available on some software versions).03083-way valve lost.0311Convertible drawer damper stuck closed.0312Convertible drawer damper stuck open.0313Convertible drawer temperature exceeded (setpoint + 20°F).0314Convertible drawer freezing when set to warm.03153-way valve cooling not detected in refrigerator evaporator.03163-way valve cooling not detected in freezer evaporator.04Refrigerator fan motor operation error0400DC Voltage for Main Control Board Out-of-Range0401Dispenser paddle switch pressed for more than 5 minutes0402Flow meter0403Flow meter signal received with no water dispensing.0404Main Control Board Hardware Fault (replace board)05Ice Maker function error05 02Flowmeter05 03Paddle switch pressed > 7 minutes; ice/water stops dispensing based on 7-minute…05 11Refrigerator icemaker thermistor reading out of range.05 12Ice box thermistor reading out of range.0500Can't reach target hot water temperature.0501Flow meter0504Hot water tank not full while heating.0505Check Hot water T&P switch and wiring0506Check Hot water T&P switch and wiring.0507Paddle switch input missing when main board has received a message it was…0508Paddle switch input present when main board has not received a message it was…0509Check hot water T & P switch and wiring.0510Hot Water Thermistor reading out of range.0513Hot water thermistor reading out of range.0514Hot water thermistor reading out of range.0515Door board relay driver is shorted (replace door board).0516HW Max Dispense Time Out Hot water disabled0517HW Max Fill Time Out, Hot water disabled.0518HW Max Dispense Time Out, Hot water disabled.0519HW Max Purge Time Out, Hot water disabled.0520Hot water max fill time out, hot water disabled.0521Hot water max dispense time out, hot water disabled.0522Hot water max purge time out, hot water disabled.0523Feature board communication error.0524Dispense nozzle movement error.0525Brew module not detected during brew.0570Dispenser nozzle motor over current error.0571Air valves over current error.0572Air pump over current error.0573Feature board hardware fault.06CoolSelect Zone sensor error06 023 out of last 10 refrigerator icemaker harvests were > 10 minutes.06 03Refrigerator icemaker harvest not complete after 30 minutes.06 05Refrigerator icemaker continues to sense bucket full after ice dispense.0600FF IM fault (N/A0601Ice maker harvest is greater than 10 minutes.0604FF IM continues to sense bucket full after ice dispense.0606FF IM continues to sense bucket full after ice dispense0650FZ IM Harvest Extended >10 mins.0651FZ IM Harvest Extended 3 out of 10 harvests.0652FZ icemaker harvest extended 3 out of 10 harvests.0653FZ icemaker harvest not completed after 30 minutes.0654Icemaker no water supply detected (this fault code not available on some…0655FZ icemaker mold heater not heating.07Refrigerator defrost error07 07Dispenser board communication error.07 09Check paddle switch and wiring07 10Check paddle switch and wiring07 14Refrigerator door open for 60 minutes total in the last 24 hours.07 1550 refrigerator left door openings in the last 24 hours.07 1650 refrigerator right door openings in the last 24 hours.0700Stuck Keys on Temperature Control Board0701Stuck keys on internal temperature board.0702Key Press on Temp Board while Door Closed.0703Key press on temperature board while door is closed.0704Key Pressed on Deli Pan Board while Door Closed.0705Key Pressed on Deli Pan Board while Door Closed0706Dispenser board auto fill error.0708Check Paddle switch and wiring.0711Check hot water T & P switch and wiring.0712FF Door open for 15 minutes continuously.0713A refrigerator door open for 15 minutes without being closed.0717FZ Door open for 60 mins0718Freezer drawer open for 60 total minutes in the last 24 hours.0719FZ Door open for 60 mins total in the last 24 hours0720Upper AutoFill Sensor Error (Clean sensors).0721AutoFill sensors detect an object present over several hours; sensors may be…0722AutoFill initialization failed.0723Capacitive touch controlled reset.0726Convertible drawer open for 15 minutes without closing.0727Convertible drawer open for 60 minutes in the last 24 hours.0728100 convertible drawer openings in the last 24 hours.0729Stuck keys on convertible drawer board.0731Convertible drawer board communication error.0732Door board communication error.0733Dispenser board communication error.0734Door-in-door open for 15 minutes continuously.0735Door-in-door open for 60 minutes in the last 24 hours.0736100 door-in-door openings in the last 24 hours.0737AutoFill termination by no water level change.0738AutoFill terminated by keypad before fill completed.0739AutoFill terminated by target removal before fill completed.0740AutoFill terminated by EMI noise.08Ambient air sensor error08 01RFID board failed to respond to the main board.0800RFID board hardware failure / check filter and filter orientation.0802RFID board not detecting filter tag / check filter and filter orientation.0803RFID filter authentication failed / check filter and filter orientation.0804N/A0805N/A09Freezer sensor error1On the last power up, the power/control module failed its self-test.10Freezer defrost sensor error11Freezer fan motor operation error12Condenser fan motor operation error13The low ambient heater is drawing less current than expected13EHumidity sensor error14The low ambient heater is drawing more current than expected14EIce maker sensor error15The PC fan is drawing less current than expected15EIce room sensor error16The PC fan is drawing more current than expected17The FC fan is drawing less current than expected18The FC fan is drawing more current than expected1EFreezer sensor error2The previous 2 defrosts were aborted after 60 minutes (RF175W) or 40 minutes…20The flapper heater current is low.21The flapper heater current is high.21EFreezer fan error22The resistance of the PC sensor 2 is outside the normal range (> 45K Ohms)22ERefrigerator fan error23The resistance of the PC sensor 2 is outside the normal range (< 660 Ohms)23ECondenser fan error24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)24EFreezer defrost function error25The resistance of the ice tray sensor is outside the normal range (< 660 Ohms)25ERefrigerator defrost function error26The icemaker motor timed out27The icemaker motor current is high.28The icemaker solenoid current is high.29The icemaker solenoid current is low.2ERefrigerator sensor error3The resistance of all the temperature sensors is outside the normal range (>…39EIce maker function error4The resistance of all the temperature sensors is outside the normal range (<…40Icemaker solenoid transistor 1 short circuit40EIce room fan error41Icemaker solenoid transistor 2 short circuit.41EMain PCB and LCD display communication error42The icemaker fill tube nozzle heater current is high43The icemaker fill tube nozzle heater current is low (element open circuit)44The PC return duct heater current is too high45The PC return duct heater current is too low4EFreezer defrost sensor error5The resistance of the FC sensor is outside the normal range (> 45K Ohms).5ERefrigerator defrost sensor error6The resistance of the FC sensor is outside the normal range (< 660 Ohms).6EAmbient sensor error7The resistance of the evaporator sensor is outside the normal range (> 45K…7EFlex sensor error8The resistance of the evaporator sensor is outside the normal range (< 660…81ECompressor starting failure82ECompressor IPM fault error83ECompressor abnormal current detection84ECompressor motor locked85ECompressor over RPM error86ECompressor over voltage888Demo Mode is active; display blinks 888 briefly then shows set temperature.8EPower-up reset display test code shown during the 5-second self-test sequence…9The resistance of the PC sensor is outside the normal range (> 45K Ohms).BBad amplifier detected during diagnostic test 07bAdThermistor is electrically open or shorted (displayed during diagnostic mode 07…bPRFID bypass plug is installed in place of a water filter.C-FAN ERRORCondenser Fan is not spinning at the correct RPM or the fan feedback line is…C1Cycle abnormal or defectiveCCFreezer temperature is warmCEIce Maker communication lost between main board and IM board (freezer displays…CFCommunication failure between main board and user interface (freezer displays…CIIcemaker is not operating properlyD2Display indicating A/S forced defrost mode is active (not a fault, service mode…dEDefrost system has failedDEFROST SENSOR OF R ROOMRefrigerator Defrost Sensor ErrordFF-Door switch defectivedrR-Door switch defectiveE0Lost communication between UI and main board for 2 minutes.E1Evaporator fan has no feedback signal to the main board.E2Condenser fan motor fault (high/low amps).E3Evaporator thermistor "sensor B" fault (out-of-range).E4Display thermistor "sensor A" fault (out-of-range).EdDefrost heater has been on for more than 60 minutes but temperature is below…EEControl and display sensor is open circuit or short circuit, or compressor has…EFEvaporator fan failure (freezer displays SY, fresh food displays EF).EhAmbient humidity sensor reading out of range.ErAmbient temperature sensor failureEr CFAbnormality of BLDC fan motor for mechanical room (condenser fan)Er COCommunication error between MICOM of Main PCB and Display MICOM, caused by poor…Er dHPoor defrostingEr dSDefrosting sensor error caused by short or disconnection of the defrosting…Er FFFailure of BLDC fan motor at freezing compartmentEr FSFreezer sensor error caused by short or disconnection of the freezer sensor.Er gFFlow meter (sensor) defectEr HSHumidity sensor error caused by short or disconnection of the humidity sensor.Er IFAbnormality of BLDC fan motor for ice makingEr ISShort or disconnection of the icing sensor (ice maker sensor)Er ItIce maker kit defectEr rFAbnormality of BLDC fan motor for refrigeratorEr rSRefrigerator sensor error caused by short or disconnection of the refrigerator…Er rtRoom temperature sensor error caused by short or disconnection of the room…Er SSPantry sensor error caused by short or disconnection of the pantry sensor.ERRNo RFID water filter or bypass plug is installed; ice and water systems are…ESWater/Crushed ice/Cube ice button errorEXT-SENSORAmbient Temperature Sensor ErrorFFail result displayed during diagnostic communication check indicating a…F dHFreezer defrosting errorF dSFreezer defrost sensor error caused by short or disconnection of the freezer…F-1- (segment a)Ambient Sensor ErrorF-1- (segment b)Freezer Sensor ErrorF-1- (segment c)Freezer Defrost Sensor ErrorF-1- (segment d)Freezer Fan ErrorF-1- (segment e)Condenser Fan ErrorF-1- (segment f)Ice Room Sensor ErrorF-1- (segment g)Freezer Defrost Heater ErrorF-1- segment aAmbient Sensor ErrorF-1- segment bFreezer Sensor ErrorF-1- segment cFreezer Defrost Sensor ErrorF-1- segment dFreezer Fan ErrorF-1- segment eCondenser Fan ErrorF-1- segment fIce Room Sensor ErrorF-1- segment gFreezer Defrost Heater ErrorF-1-aAmbient Sensor ErrorF-1-ⓐAmbient-Sensor (external temperature sensor) error due to separation of sensor…F-1-bFreezer Sensor ErrorF-1-ⓑF-Sensor (freezer room temperature sensor) error due to separation of sensor…F-1-cFreezer Defrost Sensor ErrorF-1-ⓒF-DEF-Sensor (freezer defrost sensor) error due to separation of sensor…F-1-dFreezer Fan ErrorF-1-ⓓF-FAN (freezer inner fan motor) error due to feedback signal line contact…F-1-eCondenser Fan ErrorF-1-ⓔC-FAN (compressor/machine room fan motor) error due to feedback signal line…F-1-fIce Room Sensor ErrorF-1-ⓕIce Room Sensor errorF-1-gFreezer Defrost Heater ErrorF-1-ⓖF-DEF (freezer defrost heater) error due to separation of defrost heater…F-10- (segment a)Ice Room Fan ErrorF-10- (segment f)Panel to Main Communication ErrorF-10- (segment g)Load to Main Communication ErrorF-10- segment aIce Room Fan ErrorF-10- segment fPanel to Main Communication ErrorF-10- segment gLoad to Main Communication ErrorF-10-bIce Room Fan ErrorF-10-ⓑIce Room FAN motor errorF-10-fLoad to Main Communication Error (Lc Er)F-10-gPanel to Main Communication Error (Pc Er)F-10-ⓖPanel to Main MICOM communication error displayed on panel.F-DEF-SENSORFreezer Room Defrost Sensor ErrorF-DEFROSTING ERRORFreezer defrosting heaterF-FAN ERRORFreezer Evap Fan is not spinning at the correct RPM or the fan feedback line is…F-SENSORFreezer Compartment Sensor ErrorF0Shorted OFF key or open short on the key panel.F1FF1 (Fresh Food) Thermistor InvalidF10Freezer icemaker mold body thermistor (MB) invalid (not on Café models).F100FF icemaker enters Harvest Fix Mode 3 out of 4 harvests.F101FF icemaker enters fault mode (after entering into Harvest Fault).F102FZ Fan cannot reach target RPMF103FF icemaker continues to sense bucket full after ice dispense (feeler arm…F104FF icemaker mold heater not heating (mold thermistor does not detect a 2°F…F105Condenser fan cannot reach target RPM.F106FZ icemaker stuck in Harvest Fix Mode (after 30 minutes).F107FZ icemaker enters Harvest Fix Mode 3 out of 4 harvests.F108FZ icemaker enters Fault Mode (after entering into Harvest Fault).F109FZ icemaker no water supply detected (slow or no water flow).F110Ice box fan feedback present when fan is off.F111Ice Box Fan cannot reach target RPM.F112Deli Pan/FP Fan Feedback Missing when Fan is running.F113Deli Pan/FP Fan Feedback Present when Fan is off.F114Deli Pan/FP Fan cannot reach target RPM.F115Odor filter fan feedback missing when fan is running.F116Odor filter fan feedback present when fan is off.F117Odor Filter Fan cannot reach target RPM.F120Stuck keys on ICID/ACM/Dispenser boards.F121Stuck keys on internal temp board.F122Stuck keys on Deli Pan.F123Key inputs on temp board and door closed (FF door closed and key input…F124Key inputs on deli pan board and door closed (FF door closed and key input…F125Auto fill communication error (AutoFill module not communicating properly).F126Auto fill wrong version (version not compatible with ACM version).F127ACM/COM communication error (COM module not communicating properly).F128COM wrong version (COM version not compatible with ACM).F129Cold water cup switch input missing and dispense message received from COM (ACM…F130Cold water cup switch input present and no dispense message received from COM…F131Hot water cup switch input missing and dispense message received that requires…F132Hot water cup switch input present and no dispense message received (ACM only).F133FF door open for 5 minutes without closing.F134FF door open for 60 minutes in the last 4 hours.F13580 FF door openings in the last 2 hours.F136FZ door open for 5 minutes without closing.F137FZ door open for 60 minutes in the last 4 hours.F13880 FZ door openings in the last 2 hours.F141Display board error.F2Oven over-temperatureF20FZ fan feedback missing when fan is running.F200Freezer defrost heater was on for maximum time (timed out instead of…F201Fresh food defrost heater was on for maximum time (timed out instead of…F2025 consecutive freezer abnormal defrosts occurred.F2035 consecutive fresh food abnormal defrosts occurred.F21FZ fan feedback present when fan is off.F22FZ fan cannot reach target RPM.F23Condenser fan feedback missing when fan is running.F24Condenser fan feedback present when fan is off.F25Condenser fan cannot reach target RPM.F26FF fan feedback missing when fan is running.F27FF fan feedback present when fan is off.F28FF fan cannot reach target RPM.F29Ice box fan feedback missing when fan is running.F3Freezer defrosting return abnormal or defectiveF30No display signal received (shorted or broken wire).F300Excessive Compressor Run Time (compressor ran for 5 hours; initial cycle at…F301Compressor has been off for 3 hours with the cooling system turned on.F302FF No Freeze Limit Tripped (FF crossed the No Freeze Limit).F303Fresh food temperature exceeded 75°FF304Freezer temperature exceeded 72.5°FF305Dampers Stuck Closed.F306Damper Stuck Open.F3083-Way Valve Position Lost.F31No display signal received (shorted or broken wire) clock or data line.F32Deli pan fan feedback missing when fan is running.F33Deli pan fan feedback present when fan is off.F34Deli pan fan cannot reach target RPM.F35Odor filter fan feedback missing when fan is running.F36Odor filter fan feedback present when fan is off.F37Odor filter fan cannot reach target RPM.F4FZ evaporator thermistor invalidF40FZ defrost heater on for max time.F400Main Board FailureF401Ice/water stops dispensing based on time (7 Minute Timeout); only on SxS models…F403Main Board SW (Software) FailureF404Main Board HW (Hardware) FailureF41FF defrost heater on for max time.F423 consecutive FZ abnormal defrost cycles.F433 consecutive FF abnormal defrost cycles.F5Deli Pan Thermistor InvalidF500Cannot reach target hot water temperatureF501Flow meter missingF502Flow meter pulsing with no water being dispensed (diagnostic test runs 1 minute…F503Ice/water stops dispensing based on time (7 minute time out).F504Cannot fill hot water tank without tripping the level sensorF506Cold Water paddle switch input missingF507Cold Water paddle switch input presentF508Cold water paddle switch input present (stuck).F509Hot Water T&P Switch input present when not expected.F51Cooling system was on and the compressor remained off for 6 hours.F510Door board icemaker mold temperature is invalid.F511Door board icemaker mold temperature invalid.F512Door Board Hot Water 1 Thermistor invalidF513Door Board Hot Water 2 Thermistor invalidF514Door board hot water thermistors have more than 10°F difference after 30…F515Door Board Relay driver shorted.F516Hot Water Thermistor FaultF517Hot water A/D voltage reference voltage fault.F518Hot Water Low Flow RateF519Hot water heating when tank is not full.F520Maximum Fill Time OutF521Hot Water Maximum Purge Time OutF522Hot Water Maximum Purge Time OutF523Feature Board communication error.F524Dispense nozzle movement error.F525Brew module not detected during brew.F526High flow detected during K-Cup brewing.F527Low flow detected during K-Cup brewing.F53FF temperature exceeded 75°F (defrost has not run for 1 hour, doors closed for…F54FZ temperature exceeded 30°F (defrost has not run for 1 hour, doors closed for…F570Dispenser nozzle motor over current error.F571Air valves over current error.F572Air pump over current error.F573Feature board hardware fault.F583-way valve position lost.F6Fresh food evaporator thermistor invalidF600FF Icemaker Multi-fill active 3 times in the last 10 fills.F601FF Icemaker Stuck in Harvest Fix Mode (after 10 minutes stuck in Harvest Fix…F602Fresh food door icemaker enters Harvest Fix Mode 3 out of 10 harvests.F603Fresh food door icemaker enters fault mode after entering Harvest Fault.F604FF (Door) Icemaker no water supply detectedF605Fresh food icemaker continues to sense bucket full after ice dispense; feeler…F606Fresh food door icemaker mold heater not heatingF63Main board software (SW) failureF64Main board hardware (HW) failureF650FZ Icemaker Multi-fill active 3 times in the last 10 fills.F651FZ Icemaker Stuck in Harvest Fix Mode (after 10 minutes stuck in Harvest Fix…F652FZ (Freezer) Icemaker enters Harvest Fix Mode 3 out of 10 harvests.F653FZ (Freezer) Icemaker enters Fault Mode after entering Harvest Fault.F654FZ (Freezer) Icemaker no water supply detected.F655Freezer icemaker mold heater not heatingF7Convertible Drawer Thermistor Invalid.F70Can't reach target hot water temperature (hot water time limit expires and…F700Stuck keys on ICID/ACM (Dispenser Boards).F701Stuck keys on internal temperature board.F702Stuck keys on Deli Pan board.F703Key inputs on Deli Pan Temp Board and Door Closed (FF Door is closed and a Key…F704Key Inputs on Deli Pan/FP Board and Door Closed (FF Door is closed and a key…F705Auto fill communication errorF706AutoFill wrong version; AutoFill module version not compatible with the ACM…F707ACM/Comm communication errorF708COM wrong version; COM version is not compatible with the ACM.F709Cold water cup switch input missing and dispense message received from COM (ACM…F71Flow meter missing (no pulses/flow meter signal during dispense).F710Cold Water Cup Switch Input present and no dispense message is received from…F711Hot water cup switch input missingF712Hot Water Cup Switch Input present and no dispense message is received (ACM…F713Fresh food door open for 15 minutes without closing.F714Fresh food door open for 60 minutes in the last 24 hours.F71550 fresh food door openings in the last 24 hours.F716Freezer door open for 15 minutes without closing.F717Freezer door open for 60 minutes in the last 24 hours.F71850 freezer door openings in the last 24 hours.F72Flow meter pulsing with no water dispensing (runs diagnostic test 1 minute…F722Display board error.F73Ice/water stops dispensing based on time (1 minute time out).F74Can't fill hot water tank (hot water fill time expires without tripping the…F77Cold water paddle switch input missing.F78Cold water paddle switch input present (when it should not be).F79Hot water T&P switch input missing.F8Ambient Temperature Thermistor InvalidF80Hot water T&P switch input present (when it should not be).F81Door board icemaker mold temp invalid.F82Door board ice box thermistor invalid.F83Door board hot water thermistor invalid (thermistor temperatures do not match).F84Door board hot water thermistor invalid (thermistor temperatures do not match).F9Cooling fan stall or other cause of open thermal switches in yellow or blue…F90Door board (DB) relay driver shortedF91Hot water thermistor fault (thermistor values more than 5°F difference after 60…F92Hot water A/D voltage reference voltage fault.F93Hot water low flow rateF94Hot water heating when tank not full.F95Maximum fill time outF96Maximum purge time outF97Hot water maximum purge time outF99FF icemaker stuck in Harvest Fix Mode (after 30 minutes).FDFD-sensor (freezer defrost sensor) disconnection or short circuit.FFFreezer temperature has exceeded safe thresholds indicating possible thawing of…FRENCH DOOR ICE ROOM FAN ERRORIce Room Compartment Evap Fan is not spinning at the correct RPM or the fan…FRENCH DOOR ICE ROOM SENSORIce Room Sensor ErrorHHControl and display sensor reading is more than 99°F (abnormally high…HIAmbient temperature is above 50°C, displayed on outside temperature indicator.I/M FUNCTION ERRORIce tray has not returned to level after an ice harvest; error displayed after…I/M-SENSORIce Maker Sensor ErrorIcemaker Kit ErrorEjector blades have not reached the park position after 18 minutes from start…Icemaker Sensor ErrorIcemaking sensor malfunctioniDIDUCT-sensor disconnection or short circuit.JPSJumper J4 was not removed from the power supply board after replacement…LLocked outL↔M ERROR COMMUNICATIONCommunication error within the Main PCB.Lc ErNo communication for 20 seconds between integrated circuits (IC Chips) on the…LEAKA water leak has been detected by the RFID system; ice and water systems are…LLControl and display sensor reading is less than 23°F (abnormally low…LoAmbient temperature is below -10°C, displayed on outside temperature indicator.OF - OFShowroom mode is activeOPFresh food temperature sensor is open circuit (displayed in fresh food position…OP - ErPanel to MAIN MICOM option errorOROut of RangePPass result displayed during diagnostic communication check or sensor test…P↔M ERROR COMMUNICATIONCommunication error between the Main PCB and Keypad.PANTRY-DAMPER-HEATER ERRORSensor system in Pantry Room errors.PANTRY-SENSOR ERRORCR Room Sensor ErrorPc ErNo communication for 10 seconds between control panel and main boardPFPower has been interruptedr dHRefrigerator defrosting errorr dSRefrigerator defrost sensor error caused by short or disconnection of the…R-1- (segment a)Icemaker Sensor ErrorR-1- (segment b)Refrigerator Sensor ErrorR-1- (segment c)Refrigerator Defrost Sensor ErrorR-1- (segment d)Refrigerator Fan ErrorR-1- (segment e)Icemaker ErrorR-1- (segment f)Refrigerator Defrost Heater ErrorR-1- aIcemaker Sensor ErrorR-1- dRefrigerator Fan ErrorR-1- segment aIcemaker Sensor ErrorR-1- segment bRefrigerator Sensor ErrorR-1- segment cRefrigerator Defrost Sensor ErrorR-1- segment dRefrigerator Fan ErrorR-1- segment eIcemaker ErrorR-1- segment fRefrigerator Defrost Heater ErrorR-1-ⓐIce Maker Sensor errorR-1-bRefrigerator Sensor ErrorR-1-ⓑR-Sensor (refrigerator room temperature sensor) error due to separation of…R-1-cRefrigerator Defrost Sensor ErrorR-1-ⓒR-DEF-Sensor (refrigerator defrost sensor) error due to separation of sensor…R-1-ⓓR-FAN (refrigerator inner fan motor) error due to feedback signal line contact…R-1-eIcemaker ErrorR-1-ⓔIce Maker function errorR-1-gRefrigerator Defrost Heater ErrorR-1-ⓖR-DEF (refrigerator defrost heater) error due to separation of defrost heater…R-10- (segment b)Pantry Damper Heater ErrorR-10- (segment f)Pantry Sensor ErrorR-10- (segment g)Water Tank Heater ErrorR-10- bPantry Sensor ErrorR-10- segment bPantry Damper Heater ErrorR-10- segment fPantry Sensor ErrorR-10- segment gWater Tank Heater ErrorR-10-aPantry Damper Heater ErrorR-10-ⓐPantry Damper Heater errorR-10-ⓑPantry Sensor errorR-10-gWater Tank Heater ErrorR-10-ⓖWater Tank Heater errorR-DEFROSTING ERRORRefrigerator Room defrost heaterR-FAN ERRORRefrigerator Evap Fan is not spinning at the correct RPM or the fan feedback…R-SENSORRefrigerator Room Sensor Errorr1R-sensor (refrigerator sensor) disconnection or short circuit.R2Refrigerator sensor open or short circuit.R2 R3Defrosting problemR2 R3 R4 R5 (all OFF except R2 ON)Refrigerator sensor open or short circuit detected.R2 R3 R4 R5 (pattern 2)Defrost sensor open or short circuit detected.R2 R3 R4 R5 (pattern 3)Ambient (RT) sensor open or short circuit detected.R2 R3 R4 R5 (pattern 4)Defrost time exceeded one hour and defrost sensor never reached 10°C (50°F)…R2 R3 R4 R5 (pattern 5)Freezer fan is locked (F-FAN LOCKED).R2 R4Freezer fan locked (F-FAN LOCKED).r3Fridge defrosting return abnormal or defectiveR4Ambient (RT) sensor open or short circuit.rDRD-sensor (refrigerator defrost sensor) disconnection or short circuit.rtRT-sensor (room temperature sensor) disconnection or short circuit.SThermistor shorted to 5 VDC detected during diagnostic test 07.SASabbath Mode is activeSBUnit is in Sabbath mode, normal operations are altered.SHFresh food temperature sensor is shorted (displayed in fresh food position with…SYUI to Main Control Board communication error after a period in operation.SY CEUI to Main Control Board communication error occurring after a period in…SY CFUI to Main Control Board communication failure occurring on start up.SY EFEvaporator fan failure detected.t3Ice Maker TH3 suction line sensor open or shorted (freezer displays Ice, fresh…u1V-sensor (Vita sensor) disconnection or short circuit.Uart ERROR COMMUNICATIONThis error is not applicable; if detected during diagnostic testing, ignore it.WATER HEATER ERRORWater reservoir tank heater is open or shorted.

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started