Error code reference
GE Refrigerator Error Code 07 16
50 refrigerator right door openings in the last 24 hours.
50 refrigerator right door openings in the last 24 hours.
MyPros+ Max
Get the full diagnostic procedure for 07 16.
- ✓Step-by-step tests with expected resistance, voltage, and continuity values
- ✓Wiring diagram references and connector pinouts from the OEM service manual
- ✓Verified part numbers when replacement is required
Get the full procedure→
$29/month · Cancel anytime · Or $9.95 3-day pass
M+
M+ Max·GE Refrigerator
07 16 on my GE GSS25GSHSS
M+
50 refrigerator right door openings in the last
From Service Manual 402912, p.44:
1.Access service mode to confirm the active fault code and read stored error history.
2.Measure door lock assembly resistance across the PTC terminals. Expected: ~200 ohms cold, rising sharply once energized.
3.Inspect strike and latch alignment. A warped door or misaligned strike prevents the switch stack from closing in the correct sequence.
Part WH44X10288
Door lock assembly
Related GE refrigerator codes
All GE refrigerator codes →- 0Fail result displayed during thermistor/sensor system test…
- 00No faults present.
- 00 10Freezer icemaker mold body thermistor reading out of range…
- 000Service Mode has been entered.
- 0001FF1 (Refrigerator 1) Thermistor Reading Out of Range
- 0002FF2 (Refrigerator 2) Thermistor Reading Out of Range
- 0003FZ Evaporator Thermistor reading out of range
- 0004Freezer (FZ) evaporator thermistor reading out of range.
View all 540 GE refrigerator codes
- 0005Electronic Deli Pan Thermistor reading out of range.
- 0006Refrigerator (FF) evaporator thermistor reading out of…
- 0007Ambient Humidity Sensor reading out of range
- 0008FZ Icemaker Thermistor reading out of range (if applicable)
- 0009Ambient Humidity Sensor reading out of range.
- 0011HotWater Thermistor reading out of range
- 0012HotWater Thermistor reading out of range
- 0013Quick Chill thermistor reading out of range.
- 01Test Mode 1 display indicator
- 01 05Refrigerator fan feedback missing when fan is running.
- 01 13Deli pan fan feedback present when fan is off.
- 0100Freezer (FZ) fan feedback missing when fan is running.
- 0101Freezer (FZ) fan feedback present when fan is off.
- 0102Freezer (FZ) fan cannot reach target RPM.
- 0103Condenser fan feedback missing when fan is running.
- 0104Condenser fan feedback is present when fan is off.
- 0106Refrigerator (FF) fan feedback missing when fan is running.
- 0107Refrigerator (FF) fan feedback present when fan is off.
- 0108Refrigerator (FF) fan cannot reach target RPM.
- 0109Ice box fan feedback missing when the fan is running.
- 0110Ice Box Fan Feedback Present when Fan is off.
- 0111Ice Box Fan cannot reach target speed.
- 0112Deli pan fan feedback missing when the fan is running.
- 0114Deli Pan Fan cannot reach target speed.
- 0115Odor remover fan feedback missing when the fan is running.
- 0116Odor remover fan feedback present when fan is off.
- 0117Odor remover fan cannot reach target speed.
- 02Refrigerator sensor error
- 0200FZ defrost heater timed out, 45-minutes of defrost on time…
- 0201Refrigerator defrost heater on for max time (check FF evap…
- 0202FF Defrost Heater timed out (check FF Evap thermistor fault…
- 0203Five consecutive refrigerator abnormal defrosts.
- 03Refrigerator defrost sensor error
- 0300Temperature satisfied > 3 hours (no compressor operation).
- 0301Temperatures satisfied for more than 4 hours with no…
- 0302FF temperature below freezing.
- 0303FF temperature exceeds 20°F over setpoint, 1-hour post…
- 0304FZ temperature exceeds 20°F over setpoint, 1-hour post…
- 0305N/A
- 0306N/A
- 0307Damper driver fault (this fault code not available on some…
- 03083-way valve lost.
- 0311Convertible drawer damper stuck closed.
- 0312Convertible drawer damper stuck open.
- 0313Convertible drawer temperature exceeded (setpoint + 20°F).
- 0314Convertible drawer freezing when set to warm.
- 03153-way valve cooling not detected in refrigerator evaporator.
- 03163-way valve cooling not detected in freezer evaporator.
- 04Refrigerator fan motor operation error
- 0400DC Voltage for Main Control Board Out-of-Range
- 0401Dispenser paddle switch pressed for more than 5 minutes
- 0402Flow meter
- 0403Flow meter signal received with no water dispensing.
- 0404Main Control Board Hardware Fault (replace board)
- 05Ice Maker function error
- 05 02Flowmeter
- 05 03Paddle switch pressed > 7 minutes; ice/water stops…
- 05 11Refrigerator icemaker thermistor reading out of range.
- 05 12Ice box thermistor reading out of range.
- 0500Can't reach target hot water temperature.
- 0501Flow meter
- 0504Hot water tank not full while heating.
- 0505Check Hot water T&P switch and wiring
- 0506Check Hot water T&P switch and wiring.
- 0507Paddle switch input missing when main board has received a…
- 0508Paddle switch input present when main board has not…
- 0509Check hot water T & P switch and wiring.
- 0510Hot Water Thermistor reading out of range.
- 0513Hot water thermistor reading out of range.
- 0514Hot water thermistor reading out of range.
- 0515Door board relay driver is shorted (replace door board).
- 0516HW Max Dispense Time Out Hot water disabled
- 0517HW Max Fill Time Out, Hot water disabled.
- 0518HW Max Dispense Time Out, Hot water disabled.
- 0519HW Max Purge Time Out, Hot water disabled.
- 0520Hot water max fill time out, hot water disabled.
- 0521Hot water max dispense time out, hot water disabled.
- 0522Hot water max purge time out, hot water disabled.
- 0523Feature board communication error.
- 0524Dispense nozzle movement error.
- 0525Brew module not detected during brew.
- 0570Dispenser nozzle motor over current error.
- 0571Air valves over current error.
- 0572Air pump over current error.
- 0573Feature board hardware fault.
- 06CoolSelect Zone sensor error
- 06 023 out of last 10 refrigerator icemaker harvests were > 10…
- 06 03Refrigerator icemaker harvest not complete after 30 minutes.
- 06 05Refrigerator icemaker continues to sense bucket full after…
- 0600FF IM fault (N/A
- 0601Ice maker harvest is greater than 10 minutes.
- 0604FF IM continues to sense bucket full after ice dispense.
- 0606FF IM continues to sense bucket full after ice dispense
- 0650FZ IM Harvest Extended >10 mins.
- 0651FZ IM Harvest Extended 3 out of 10 harvests.
- 0652FZ icemaker harvest extended 3 out of 10 harvests.
- 0653FZ icemaker harvest not completed after 30 minutes.
- 0654Icemaker no water supply detected (this fault code not…
- 0655FZ icemaker mold heater not heating.
- 07Refrigerator defrost error
- 07 07Dispenser board communication error.
- 07 09Check paddle switch and wiring
- 07 10Check paddle switch and wiring
- 07 14Refrigerator door open for 60 minutes total in the last 24…
- 07 1550 refrigerator left door openings in the last 24 hours.
- 0700Stuck Keys on Temperature Control Board
- 0701Stuck keys on internal temperature board.
- 0702Key Press on Temp Board while Door Closed.
- 0703Key press on temperature board while door is closed.
- 0704Key Pressed on Deli Pan Board while Door Closed.
- 0705Key Pressed on Deli Pan Board while Door Closed
- 0706Dispenser board auto fill error.
- 0708Check Paddle switch and wiring.
- 0711Check hot water T & P switch and wiring.
- 0712FF Door open for 15 minutes continuously.
- 0713A refrigerator door open for 15 minutes without being…
- 0717FZ Door open for 60 mins
- 0718Freezer drawer open for 60 total minutes in the last 24…
- 0719FZ Door open for 60 mins total in the last 24 hours
- 0720Upper AutoFill Sensor Error (Clean sensors).
- 0721AutoFill sensors detect an object present over several…
- 0722AutoFill initialization failed.
- 0723Capacitive touch controlled reset.
- 0726Convertible drawer open for 15 minutes without closing.
- 0727Convertible drawer open for 60 minutes in the last 24 hours.
- 0728100 convertible drawer openings in the last 24 hours.
- 0729Stuck keys on convertible drawer board.
- 0731Convertible drawer board communication error.
- 0732Door board communication error.
- 0733Dispenser board communication error.
- 0734Door-in-door open for 15 minutes continuously.
- 0735Door-in-door open for 60 minutes in the last 24 hours.
- 0736100 door-in-door openings in the last 24 hours.
- 0737AutoFill termination by no water level change.
- 0738AutoFill terminated by keypad before fill completed.
- 0739AutoFill terminated by target removal before fill completed.
- 0740AutoFill terminated by EMI noise.
- 08Ambient air sensor error
- 08 01RFID board failed to respond to the main board.
- 0800RFID board hardware failure / check filter and filter…
- 0802RFID board not detecting filter tag / check filter and…
- 0803RFID filter authentication failed / check filter and filter…
- 0804N/A
- 0805N/A
- 09Freezer sensor error
- 1On the last power up, the power/control module failed its…
- 10Freezer defrost sensor error
- 11Freezer fan motor operation error
- 12Condenser fan motor operation error
- 13The low ambient heater is drawing less current than expected
- 13EHumidity sensor error
- 14The low ambient heater is drawing more current than expected
- 14EIce maker sensor error
- 15The PC fan is drawing less current than expected
- 15EIce room sensor error
- 16The PC fan is drawing more current than expected
- 17The FC fan is drawing less current than expected
- 18The FC fan is drawing more current than expected
- 1EFreezer sensor error
- 2The previous 2 defrosts were aborted after 60 minutes…
- 20The flapper heater current is low.
- 21The flapper heater current is high.
- 21EFreezer fan error
- 22The resistance of the PC sensor 2 is outside the normal…
- 22ERefrigerator fan error
- 23The resistance of the PC sensor 2 is outside the normal…
- 23ECondenser fan error
- 24The resistance of the ice tray sensor is outside the normal…
- 24EFreezer defrost function error
- 25The resistance of the ice tray sensor is outside the normal…
- 25ERefrigerator defrost function error
- 26The icemaker motor timed out
- 27The icemaker motor current is high.
- 28The icemaker solenoid current is high.
- 29The icemaker solenoid current is low.
- 2ERefrigerator sensor error
- 3The resistance of all the temperature sensors is outside…
- 39EIce maker function error
- 4The resistance of all the temperature sensors is outside…
- 40Icemaker solenoid transistor 1 short circuit
- 40EIce room fan error
- 41Icemaker solenoid transistor 2 short circuit.
- 41EMain PCB and LCD display communication error
- 42The icemaker fill tube nozzle heater current is high
- 43The icemaker fill tube nozzle heater current is low…
- 44The PC return duct heater current is too high
- 45The PC return duct heater current is too low
- 4EFreezer defrost sensor error
- 5The resistance of the FC sensor is outside the normal range…
- 5ERefrigerator defrost sensor error
- 6The resistance of the FC sensor is outside the normal range…
- 6EAmbient sensor error
- 7The resistance of the evaporator sensor is outside the…
- 7EFlex sensor error
- 8The resistance of the evaporator sensor is outside the…
- 81ECompressor starting failure
- 82ECompressor IPM fault error
- 83ECompressor abnormal current detection
- 84ECompressor motor locked
- 85ECompressor over RPM error
- 86ECompressor over voltage
- 888Demo Mode is active; display blinks 888 briefly then shows…
- 8EPower-up reset display test code shown during the 5-second…
- 9The resistance of the PC sensor is outside the normal range…
- BBad amplifier detected during diagnostic test 07
- bAdThermistor is electrically open or shorted (displayed…
- bPRFID bypass plug is installed in place of a water filter.
- C-FAN ERRORCondenser Fan is not spinning at the correct RPM or the fan…
- C1Cycle abnormal or defective
- CCFreezer temperature is warm
- CEIce Maker communication lost between main board and IM…
- CFCommunication failure between main board and user interface…
- CIIcemaker is not operating properly
- D2Display indicating A/S forced defrost mode is active (not a…
- dEDefrost system has failed
- DEFROST SENSOR OF R ROOMRefrigerator Defrost Sensor Error
- dFF-Door switch defective
- drR-Door switch defective
- E0Lost communication between UI and main board for 2 minutes.
- E1Evaporator fan has no feedback signal to the main board.
- E2Condenser fan motor fault (high/low amps).
- E3Evaporator thermistor "sensor B" fault (out-of-range).
- E4Display thermistor "sensor A" fault (out-of-range).
- EdDefrost heater has been on for more than 60 minutes but…
- EEControl and display sensor is open circuit or short…
- EFEvaporator fan failure (freezer displays SY, fresh food…
- EhAmbient humidity sensor reading out of range.
- ErAmbient temperature sensor failure
- Er CFAbnormality of BLDC fan motor for mechanical room…
- Er COCommunication error between MICOM of Main PCB and Display…
- Er dHPoor defrosting
- Er dSDefrosting sensor error caused by short or disconnection of…
- Er FFFailure of BLDC fan motor at freezing compartment
- Er FSFreezer sensor error caused by short or disconnection of…
- Er gFFlow meter (sensor) defect
- Er HSHumidity sensor error caused by short or disconnection of…
- Er IFAbnormality of BLDC fan motor for ice making
- Er ISShort or disconnection of the icing sensor (ice maker…
- Er ItIce maker kit defect
- Er rFAbnormality of BLDC fan motor for refrigerator
- Er rSRefrigerator sensor error caused by short or disconnection…
- Er rtRoom temperature sensor error caused by short or…
- Er SSPantry sensor error caused by short or disconnection of the…
- ERRNo RFID water filter or bypass plug is installed; ice and…
- ESWater/Crushed ice/Cube ice button error
- EXT-SENSORAmbient Temperature Sensor Error
- FFail result displayed during diagnostic communication check…
- F dHFreezer defrosting error
- F dSFreezer defrost sensor error caused by short or…
- F-1- (segment a)Ambient Sensor Error
- F-1- (segment b)Freezer Sensor Error
- F-1- (segment c)Freezer Defrost Sensor Error
- F-1- (segment d)Freezer Fan Error
- F-1- (segment e)Condenser Fan Error
- F-1- (segment f)Ice Room Sensor Error
- F-1- (segment g)Freezer Defrost Heater Error
- F-1-aAmbient Sensor Error
- F-1-ⓐAmbient-Sensor (external temperature sensor) error due to…
- F-1-bFreezer Sensor Error
- F-1-cFreezer Defrost Sensor Error
- F-1-dFreezer Fan Error
- F-1-eCondenser Fan Error
- F-1-fIce Room Sensor Error
- F-1-gFreezer Defrost Heater Error
- F-10- (segment a)Ice Room Fan Error
- F-10- (segment f)Panel to Main Communication Error
- F-10- (segment g)Load to Main Communication Error
- F-10-bIce Room Fan Error
- F-10-ⓑIce Room FAN motor error
- F-10-fLoad to Main Communication Error (Lc Er)
- F-10-gPanel to Main Communication Error (Pc Er)
- F-DEF-SENSORFreezer Room Defrost Sensor Error
- F-DEFROSTING ERRORFreezer defrosting heater
- F-FAN ERRORFreezer Evap Fan is not spinning at the correct RPM or the…
- F-SENSORFreezer Compartment Sensor Error
- F0Shorted OFF key or open short on the key panel.
- F1FF1 (Fresh Food) Thermistor Invalid
- F10Freezer icemaker mold body thermistor (MB) invalid (not on…
- F100FF icemaker enters Harvest Fix Mode 3 out of 4 harvests.
- F101FF icemaker enters fault mode (after entering into Harvest…
- F102FZ Fan cannot reach target RPM
- F103FF icemaker continues to sense bucket full after ice…
- F104FF icemaker mold heater not heating (mold thermistor does…
- F105Condenser fan cannot reach target RPM.
- F106FZ icemaker stuck in Harvest Fix Mode (after 30 minutes).
- F107FZ icemaker enters Harvest Fix Mode 3 out of 4 harvests.
- F108FZ icemaker enters Fault Mode (after entering into Harvest…
- F109FZ icemaker no water supply detected (slow or no water…
- F110Ice box fan feedback present when fan is off.
- F111Ice Box Fan cannot reach target RPM.
- F112Deli Pan/FP Fan Feedback Missing when Fan is running.
- F113Deli Pan/FP Fan Feedback Present when Fan is off.
- F114Deli Pan/FP Fan cannot reach target RPM.
- F115Odor filter fan feedback missing when fan is running.
- F116Odor filter fan feedback present when fan is off.
- F117Odor Filter Fan cannot reach target RPM.
- F120Stuck keys on ICID/ACM/Dispenser boards.
- F121Stuck keys on internal temp board.
- F122Stuck keys on Deli Pan.
- F123Key inputs on temp board and door closed (FF door closed…
- F124Key inputs on deli pan board and door closed (FF door…
- F125Auto fill communication error (AutoFill module not…
- F126Auto fill wrong version (version not compatible with ACM…
- F127ACM/COM communication error (COM module not communicating…
- F128COM wrong version (COM version not compatible with ACM).
- F129Cold water cup switch input missing and dispense message…
- F130Cold water cup switch input present and no dispense message…
- F131Hot water cup switch input missing and dispense message…
- F132Hot water cup switch input present and no dispense message…
- F133FF door open for 5 minutes without closing.
- F134FF door open for 60 minutes in the last 4 hours.
- F13580 FF door openings in the last 2 hours.
- F136FZ door open for 5 minutes without closing.
- F137FZ door open for 60 minutes in the last 4 hours.
- F13880 FZ door openings in the last 2 hours.
- F141Display board error.
- F2Oven over-temperature
- F20FZ fan feedback missing when fan is running.
- F200Freezer defrost heater was on for maximum time (timed out…
- F201Fresh food defrost heater was on for maximum time (timed…
- F2025 consecutive freezer abnormal defrosts occurred.
- F2035 consecutive fresh food abnormal defrosts occurred.
- F21FZ fan feedback present when fan is off.
- F22FZ fan cannot reach target RPM.
- F23Condenser fan feedback missing when fan is running.
- F24Condenser fan feedback present when fan is off.
- F25Condenser fan cannot reach target RPM.
- F26FF fan feedback missing when fan is running.
- F27FF fan feedback present when fan is off.
- F28FF fan cannot reach target RPM.
- F29Ice box fan feedback missing when fan is running.
- F3Freezer defrosting return abnormal or defective
- F30No display signal received (shorted or broken wire).
- F300Excessive Compressor Run Time (compressor ran for 5 hours…
- F301Compressor has been off for 3 hours with the cooling system…
- F302FF No Freeze Limit Tripped (FF crossed the No Freeze Limit).
- F303Fresh food temperature exceeded 75°F
- F304Freezer temperature exceeded 72.5°F
- F305Dampers Stuck Closed.
- F306Damper Stuck Open.
- F3083-Way Valve Position Lost.
- F31No display signal received (shorted or broken wire) clock…
- F32Deli pan fan feedback missing when fan is running.
- F33Deli pan fan feedback present when fan is off.
- F34Deli pan fan cannot reach target RPM.
- F35Odor filter fan feedback missing when fan is running.
- F36Odor filter fan feedback present when fan is off.
- F37Odor filter fan cannot reach target RPM.
- F4FZ evaporator thermistor invalid
- F40FZ defrost heater on for max time.
- F400Main Board Failure
- F401Ice/water stops dispensing based on time (7 Minute…
- F403Main Board SW (Software) Failure
- F404Main Board HW (Hardware) Failure
- F41FF defrost heater on for max time.
- F423 consecutive FZ abnormal defrost cycles.
- F433 consecutive FF abnormal defrost cycles.
- F5Deli Pan Thermistor Invalid
- F500Cannot reach target hot water temperature
- F501Flow meter missing
- F502Flow meter pulsing with no water being dispensed…
- F503Ice/water stops dispensing based on time (7 minute time…
- F504Cannot fill hot water tank without tripping the level sensor
- F506Cold Water paddle switch input missing
- F507Cold Water paddle switch input present
- F508Cold water paddle switch input present (stuck).
- F509Hot Water T&P Switch input present when not expected.
- F51Cooling system was on and the compressor remained off for 6…
- F510Door board icemaker mold temperature is invalid.
- F511Door board icemaker mold temperature invalid.
- F512Door Board Hot Water 1 Thermistor invalid
- F513Door Board Hot Water 2 Thermistor invalid
- F514Door board hot water thermistors have more than 10°F…
- F515Door Board Relay driver shorted.
- F516Hot Water Thermistor Fault
- F517Hot water A/D voltage reference voltage fault.
- F518Hot Water Low Flow Rate
- F519Hot water heating when tank is not full.
- F520Maximum Fill Time Out
- F521Hot Water Maximum Purge Time Out
- F522Hot Water Maximum Purge Time Out
- F523Feature Board communication error.
- F524Dispense nozzle movement error.
- F525Brew module not detected during brew.
- F526High flow detected during K-Cup brewing.
- F527Low flow detected during K-Cup brewing.
- F53FF temperature exceeded 75°F (defrost has not run for 1…
- F54FZ temperature exceeded 30°F (defrost has not run for 1…
- F570Dispenser nozzle motor over current error.
- F571Air valves over current error.
- F572Air pump over current error.
- F573Feature board hardware fault.
- F583-way valve position lost.
- F6Fresh food evaporator thermistor invalid
- F600FF Icemaker Multi-fill active 3 times in the last 10 fills.
- F601FF Icemaker Stuck in Harvest Fix Mode (after 10 minutes…
- F602Fresh food door icemaker enters Harvest Fix Mode 3 out of…
- F603Fresh food door icemaker enters fault mode after entering…
- F604FF (Door) Icemaker no water supply detected
- F605Fresh food icemaker continues to sense bucket full after…
- F606Fresh food door icemaker mold heater not heating
- F63Main board software (SW) failure
- F64Main board hardware (HW) failure
- F650FZ Icemaker Multi-fill active 3 times in the last 10 fills.
- F651FZ Icemaker Stuck in Harvest Fix Mode (after 10 minutes…
- F652FZ (Freezer) Icemaker enters Harvest Fix Mode 3 out of 10…
- F653FZ (Freezer) Icemaker enters Fault Mode after entering…
- F654FZ (Freezer) Icemaker no water supply detected.
- F655Freezer icemaker mold heater not heating
- F7Convertible Drawer Thermistor Invalid.
- F70Can't reach target hot water temperature (hot water time…
- F700Stuck keys on ICID/ACM (Dispenser Boards).
- F701Stuck keys on internal temperature board.
- F702Stuck keys on Deli Pan board.
- F703Key inputs on Deli Pan Temp Board and Door Closed (FF Door…
- F704Key Inputs on Deli Pan/FP Board and Door Closed (FF Door is…
- F705Auto fill communication error
- F706AutoFill wrong version; AutoFill module version not…
- F707ACM/Comm communication error
- F708COM wrong version; COM version is not compatible with the…
- F709Cold water cup switch input missing and dispense message…
- F71Flow meter missing (no pulses/flow meter signal during…
- F710Cold Water Cup Switch Input present and no dispense message…
- F711Hot water cup switch input missing
- F712Hot Water Cup Switch Input present and no dispense message…
- F713Fresh food door open for 15 minutes without closing.
- F714Fresh food door open for 60 minutes in the last 24 hours.
- F71550 fresh food door openings in the last 24 hours.
- F716Freezer door open for 15 minutes without closing.
- F717Freezer door open for 60 minutes in the last 24 hours.
- F71850 freezer door openings in the last 24 hours.
- F72Flow meter pulsing with no water dispensing (runs…
- F722Display board error.
- F73Ice/water stops dispensing based on time (1 minute time…
- F74Can't fill hot water tank (hot water fill time expires…
- F77Cold water paddle switch input missing.
- F78Cold water paddle switch input present (when it should not…
- F79Hot water T&P switch input missing.
- F8Ambient Temperature Thermistor Invalid
- F80Hot water T&P switch input present (when it should not be).
- F81Door board icemaker mold temp invalid.
- F82Door board ice box thermistor invalid.
- F83Door board hot water thermistor invalid (thermistor…
- F84Door board hot water thermistor invalid (thermistor…
- F9Cooling fan stall or other cause of open thermal switches…
- F90Door board (DB) relay driver shorted
- F91Hot water thermistor fault (thermistor values more than 5°F…
- F92Hot water A/D voltage reference voltage fault.
- F93Hot water low flow rate
- F94Hot water heating when tank not full.
- F95Maximum fill time out
- F96Maximum purge time out
- F97Hot water maximum purge time out
- F99FF icemaker stuck in Harvest Fix Mode (after 30 minutes).
- FDFD-sensor (freezer defrost sensor) disconnection or short…
- FFFreezer temperature has exceeded safe thresholds indicating…
- FRENCH DOOR ICE ROOM FAN ERRORIce Room Compartment Evap Fan is not spinning at the…
- FRENCH DOOR ICE ROOM SENSORIce Room Sensor Error
- HHControl and display sensor reading is more than 99°F…
- HIAmbient temperature is above 50°C, displayed on outside…
- I/M FUNCTION ERRORIce tray has not returned to level after an ice harvest…
- I/M-SENSORIce Maker Sensor Error
- Icemaker Kit ErrorEjector blades have not reached the park position after 18…
- Icemaker Sensor ErrorIcemaking sensor malfunction
- iDIDUCT-sensor disconnection or short circuit.
- JPSJumper J4 was not removed from the power supply board after…
- LLocked out
- L↔M ERROR COMMUNICATIONCommunication error within the Main PCB.
- Lc ErNo communication for 20 seconds between integrated circuits…
- LEAKA water leak has been detected by the RFID system; ice and…
- LLControl and display sensor reading is less than 23°F…
- LoAmbient temperature is below -10°C, displayed on outside…
- OF - OFShowroom mode is active
- OPFresh food temperature sensor is open circuit (displayed in…
- OP - ErPanel to MAIN MICOM option error
- OROut of Range
- PPass result displayed during diagnostic communication check…
- P↔M ERROR COMMUNICATIONCommunication error between the Main PCB and Keypad.
- PANTRY-DAMPER-HEATER ERRORSensor system in Pantry Room errors.
- PANTRY-SENSOR ERRORCR Room Sensor Error
- Pc ErNo communication for 10 seconds between control panel and…
- PFPower has been interrupted
- r dHRefrigerator defrosting error
- r dSRefrigerator defrost sensor error caused by short or…
- R-1- (segment a)Icemaker Sensor Error
- R-1- (segment b)Refrigerator Sensor Error
- R-1- (segment c)Refrigerator Defrost Sensor Error
- R-1- (segment d)Refrigerator Fan Error
- R-1- (segment e)Icemaker Error
- R-1- (segment f)Refrigerator Defrost Heater Error
- R-1- aIcemaker Sensor Error
- R-1- dRefrigerator Fan Error
- R-1-ⓐIce Maker Sensor error
- R-1-bRefrigerator Sensor Error
- R-1-cRefrigerator Defrost Sensor Error
- R-1-eIcemaker Error
- R-1-gRefrigerator Defrost Heater Error
- R-10- (segment b)Pantry Damper Heater Error
- R-10- (segment f)Pantry Sensor Error
- R-10- (segment g)Water Tank Heater Error
- R-10- bPantry Sensor Error
- R-10-aPantry Damper Heater Error
- R-10-ⓐPantry Damper Heater error
- R-10-gWater Tank Heater Error
- R-DEFROSTING ERRORRefrigerator Room defrost heater
- R-FAN ERRORRefrigerator Evap Fan is not spinning at the correct RPM or…
- R-SENSORRefrigerator Room Sensor Error
- r1R-sensor (refrigerator sensor) disconnection or short…
- R2Refrigerator sensor open or short circuit.
- R2 R3Defrosting problem
- R2 R3 R4 R5 (all OFF except R2 ON)Refrigerator sensor open or short circuit detected.
- R2 R3 R4 R5 (pattern 2)Defrost sensor open or short circuit detected.
- R2 R3 R4 R5 (pattern 3)Ambient (RT) sensor open or short circuit detected.
- R2 R3 R4 R5 (pattern 4)Defrost time exceeded one hour and defrost sensor never…
- R2 R3 R4 R5 (pattern 5)Freezer fan is locked (F-FAN LOCKED).
- R2 R4Freezer fan locked (F-FAN LOCKED).
- r3Fridge defrosting return abnormal or defective
- R4Ambient (RT) sensor open or short circuit.
- rDRD-sensor (refrigerator defrost sensor) disconnection or…
- rtRT-sensor (room temperature sensor) disconnection or short…
- SThermistor shorted to 5 VDC detected during diagnostic test…
- SASabbath Mode is active
- SBUnit is in Sabbath mode, normal operations are altered.
- SHFresh food temperature sensor is shorted (displayed in…
- SYUI to Main Control Board communication error after a period…
- SY CEUI to Main Control Board communication error occurring…
- SY CFUI to Main Control Board communication failure occurring on…
- SY EFEvaporator fan failure detected.
- t3Ice Maker TH3 suction line sensor open or shorted (freezer…
- u1V-sensor (Vita sensor) disconnection or short circuit.
- Uart ERROR COMMUNICATIONThis error is not applicable; if detected during diagnostic…
- WATER HEATER ERRORWater reservoir tank heater is open or shorted.
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started →$29/month · Cancel anytime · Or $9.95 3-day pass