mypros+
Error code reference

GE Refrigerator Error Code 0701

Stuck keys on internal temperature board.

Stuck keys on internal temperature board.

MyPros+ Max

Get the full diagnostic procedure for 0701.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 0701 means on a GE refrigerator

Error code 0701 on a GE refrigerator indicates that the internal temperature control board has detected one or more stuck keys. The board continuously monitors the state of its keypad inputs, and when a key registers as continuously pressed beyond a normal threshold, the board flags this fault. The affected component is the internal temp board, which typically refers to the user interface or dispenser control panel that houses the temperature adjustment buttons.

For homeowners, this means one or more buttons on your refrigerator's control panel is either physically stuck in the pressed position or is sending a constant signal to the board as if it were being held down. This can happen because of a sticky residue under a button, a warped keypad membrane, or a failure in the board's input circuitry itself. The refrigerator may still cool normally, but the control panel will likely be unresponsive or behave erratically while this code is active.

The fault can be triggered by physical debris or liquid intrusion around the keypad, a damaged flex ribbon cable connecting the keypad to the board, or a defective internal temp board. Identifying which key is stuck, if any, is the first diagnostic step before ordering parts.

Source: manufacturer service documentation.

Common causes of 0701

  1. 01

    Debris or liquid under keypad buttons

    Wiring / connection

    Food residue, cleaning spray, or spilled liquid can seep beneath the keypad membrane and hold a button in constant contact with its switch. This creates a persistent keypress signal that triggers the 0701 fault.

  2. 02

    Damaged or warped keypad membrane

    Part replacement

    The flexible membrane overlay that sits over the keypad buttons can warp, crack, or deform over time, causing one or more buttons to press against the switch contacts continuously. Replacing the keypad membrane or user interface panel resolves this.

  3. 03

    Faulty flex ribbon cable between keypad and control board

    Part replacement

    The ribbon cable that carries button signals from the keypad to the internal temp board can develop a short or crimp, causing the board to read a constant keypress on one or more inputs. A damaged ribbon cable requires replacement of the cable or the associated panel assembly.

  4. 04

    Failed internal temp board

    Part replacement

    If the keypad and ribbon cable check out physically, the internal temp board itself may have failed input circuitry that incorrectly reports a stuck key even when no button is pressed. This is less common but requires replacing the board.

See the test procedure for each cause

Frequently asked questions about 0701

What does error code 0701 mean on a GE refrigerator?
Error code 0701 means the internal temperature control board has detected a stuck key, meaning one or more buttons on the control panel is registering as continuously pressed. This can be caused by debris under the keypad, a damaged membrane, a faulty ribbon cable, or a failed board. The refrigerator may continue cooling but the control panel will likely be unresponsive.
How do I fix error code 0701 on a GE refrigerator?
Start by inspecting the control panel buttons for any that feel physically stuck or have sticky residue around them. Clean around the keys with a dry or lightly damp cloth and press each button to check for one that does not spring back normally. If no button is visibly stuck, the keypad membrane or the internal temp board likely needs to be replaced. Disconnect power for a few minutes first to see if the code clears on its own after a reset.
Can I still use my GE refrigerator when it shows code 0701?
In most cases, yes. The 0701 code is a control panel fault, not a compressor or sealed system fault, so the refrigerator typically continues to cool. However, you may lose the ability to adjust temperature settings or use other panel functions until the stuck key issue is resolved. Monitor the actual temperature inside the fridge with a thermometer to confirm it is holding at safe levels.
How much does it cost to fix error code 0701 on a GE refrigerator?
If the fix is just cleaning debris from around a stuck button, there is no parts cost. A replacement keypad membrane or user interface panel typically runs between $30 and $100 depending on the model. A new internal temp board can range from $60 to $200 in parts. If you hire a technician, expect $100 to $200 in labor on top of parts costs.
Will unplugging my GE refrigerator clear the 0701 error code?
A power reset by unplugging for 5 minutes may temporarily clear the 0701 code, but if the underlying cause is a physically stuck key, damaged membrane, or failed board, the code will return. Use the reset as a diagnostic step to confirm whether the fault is intermittent or consistent. A code that immediately returns after a reset points to a hardware issue that needs physical inspection and likely a replacement part.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass