mypros+
Error code reference

GE Refrigerator Error Code 0711

Check hot water T & P switch and wiring.

Check hot water T & P switch and wiring.

First step from the service manual

Check hot water T & P switch and wiring.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 0711.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 0711 means on a GE refrigerator

Error code 0711 on a GE refrigerator indicates the control board has detected a problem with the hot water temperature and pressure (T&P) switch or its associated wiring circuit. This switch monitors conditions within the hot water system, and when the board cannot read a valid signal from it, the fault code is triggered. The most direct diagnostic path is inspecting the T&P switch itself and tracing the wiring harness connected to it for damage, corrosion, or loose terminals.

For homeowners, this code means the refrigerator's control system is not getting the expected feedback from a safety-related switch that monitors hot water temperature and pressure. Think of this switch as a sensor that tells the board everything is within safe operating limits. When the signal is missing or out of range, the board flags it as a fault. This does not necessarily mean a catastrophic failure has occurred, but it does mean something in that circuit needs attention before the system can operate normally.

The fault could stem from a failed T&P switch, a broken or corroded wire in the harness leading to it, a loose connector at either end of the circuit, or in less common cases, a fault on the control board itself. Start diagnostics at the switch and work back through the wiring before concluding the board is at fault.

Source: manufacturer service documentation.

Common causes of 0711

  1. 01

    Failed hot water T&P switch

    Part replacement

    The T&P switch itself has failed internally, either staying open or closed outside of its normal operating parameters. When this happens, the control board receives no valid signal and sets code 0711.

  2. 02

    Damaged or broken wiring harness

    Part replacement

    The wiring between the T&P switch and the control board may have a break, short, or damaged insulation. Physical damage from pinching, heat exposure, or wear can interrupt the signal and trigger this code.

  3. 03

    Loose or corroded connector

    Wiring / connection

    The connector terminal at the T&P switch or the control board end of the harness may be loose or corroded, creating an intermittent or lost connection. This is one of the first things to check visually and can sometimes be resolved without replacing parts.

  4. 04

    Faulty control board

    Part replacement

    If the T&P switch and all wiring check out as functional and properly connected, the control board may have a failed input circuit for this sensor. This is the least common cause and should only be considered after the switch and wiring are confirmed good.

See the test procedure for each cause

Frequently asked questions about 0711

What does error code 0711 mean on a GE refrigerator?
Code 0711 means the control board has detected a fault in the hot water temperature and pressure (T&P) switch circuit. This includes the switch itself and the wiring connected to it. The board is not receiving a valid signal from the switch, which prompts the fault. Checking the switch condition and inspecting the wiring harness and connectors is the correct first step.
How do I fix error code 0711 on a GE refrigerator?
Start by locating the hot water T&P switch and visually inspecting its wiring and connectors for damage, corrosion, or loose terminals. Reconnect or clean any suspect connections and check if the code clears. If the wiring looks intact, test the T&P switch itself for continuity with a multimeter. A switch that reads open when it should be closed, or vice versa, needs replacement. If the switch and wiring both test good, the control board may need further evaluation by a technician.
Is it safe to use my GE refrigerator while code 0711 is active?
The T&P switch is a safety-monitoring component, so operating the refrigerator with this fault active is not advisable for an extended period. The system may not be able to respond correctly to abnormal temperature or pressure conditions in the hot water circuit. Use the unit only for short durations while sourcing parts or scheduling a repair, and monitor it closely for any additional symptoms.
How much does it cost to fix a GE refrigerator with error code 0711?
If the repair only requires reseating a connector or cleaning a corroded terminal, there is no parts cost. A replacement T&P switch typically costs between $20 and $60 depending on the model. If a technician is needed, expect a service call fee of $80 to $150 plus labor, bringing the total to roughly $100 to $250 for a switch replacement. Control board replacement, if required, is more expensive and can range from $150 to $400 or more for parts alone.
Can a loose wire cause code 0711 on a GE refrigerator?
Yes, a loose or corroded connector is one of the more common causes of code 0711. The control board needs a continuous, valid signal from the T&P switch, and a poor connection interrupts that signal just as effectively as a failed switch. Inspect both the connector at the switch and the connector at the board before replacing any parts, since reseating a loose terminal may resolve the fault without any cost.