Goodman Heat Pump Error Code 07

Open run circuit

Open run circuit - compressor run winding is open, compressor not properly wired, or faulty compressor wiring.

First step from the service manual

Check compressor; repair/replace as needed. Check wiring.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 07.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 07 means on a Goodman heat pump

Goodman heat pump fault code 07 indicates an open run circuit at the compressor. The run winding is one of two primary windings in a single-phase compressor motor, responsible for sustaining motor rotation during normal operation. When the control board detects that current is not flowing through the run winding circuit as expected, it logs this fault and shuts down compressor operation to prevent damage. An open circuit in this context means electrical continuity has been lost somewhere between the control board output and the compressor motor terminals.

The three primary sources of this fault are a failed compressor run winding, improper or incomplete wiring connections, and damaged wiring in the compressor circuit. A compressor with an open run winding has an internal motor failure and will require compressor replacement. Wiring issues can include loose terminals at the compressor contactor, corroded or disconnected spade terminals at the compressor itself, or a broken wire in the harness running to the compressor. The control board reads this condition by monitoring the run circuit and flagging the absence of expected electrical continuity or current draw.

Diagnosing this fault requires isolating whether the open circuit exists in the compressor motor itself or in the external wiring. Using a multimeter, a technician should first verify continuity and resistance across the compressor run winding terminals. A reading of infinite resistance between the run and common terminals confirms an open winding internally. If the winding tests normal, the wiring from the contactor to the compressor terminals should be inspected for damage, loose connections, or corrosion before condemning the compressor.

Source: manufacturer service documentation.

Common causes of 07

  1. 01

    Failed compressor run winding

    Part replacement

    The internal run winding of the compressor motor has broken open, meaning electrical continuity is lost inside the motor itself. This is confirmed by measuring infinite resistance between the run and common terminals on the compressor.

  2. 02

    Loose or disconnected compressor wiring terminals

    Wiring / connection

    Spade or ring terminals at the compressor motor connection points can loosen or pull free due to vibration or heat cycling. Inspect all terminals at the compressor and at the contactor for secure, corrosion-free connections.

  3. 03

    Damaged or broken wiring in the compressor circuit

    Part replacement

    The wiring harness between the contactor and the compressor can be damaged by rodents, pinching, or insulation breakdown. A visual inspection followed by a continuity check on each wire will identify any broken conductors.

  4. 04

    Improper compressor wiring configuration

    Wiring / connection

    If the compressor was recently serviced or replaced, incorrect wiring of the run, start, and common terminals can create an open run circuit condition. Verifying the terminal wiring matches the correct configuration for the compressor model resolves this.

See the test procedure for each cause

Frequently asked questions about 07

What does 07 mean on a Goodman heat_pump?
Fault code 07 on a Goodman heat pump indicates an open run circuit at the compressor. This means the control board cannot detect proper electrical continuity or current flow through the compressor run winding circuit. The cause may be a failed internal run winding, faulty wiring, or loose connections between the contactor and the compressor. The system will not operate until the fault is resolved.
Can I fix a Goodman heat pump fault code 07 myself?
Wiring inspection and terminal tightening at the compressor and contactor can be performed by a knowledgeable DIYer with the power safely disconnected. However, testing compressor windings with a multimeter and replacing a failed compressor require refrigerant handling certification and electrical expertise, so those steps should be handled by a licensed HVAC technician. Do not energize the system if wiring is visibly damaged.
Is it safe to run my heat pump when fault code 07 is active?
No. Fault code 07 means the compressor is not operating correctly, and the control board has shut down the system to prevent damage. Attempting to force the unit to run with an open run circuit can cause additional electrical damage to the compressor or control board. Leave the system off until the wiring and compressor have been inspected and the fault is corrected.
How much does it cost to repair a Goodman heat pump with fault code 07?
Repair costs depend on what is causing the open run circuit. If the issue is a loose or damaged wire, repair costs are typically in the range of $75 to $250 for a service call and labor. If the compressor run winding has failed and the compressor needs replacement, costs can range from $1,200 to $2,800 or more depending on the unit size and local labor rates. A technician will need to diagnose the root cause before providing an accurate estimate.
Will resetting my Goodman heat pump clear fault code 07?
Resetting the control board may temporarily clear the fault code display, but the underlying problem causing the open run circuit will remain. If the compressor winding is open or wiring is damaged, the fault will return immediately when the system attempts to start the compressor. A reset is not a repair, and the system should be properly diagnosed and serviced before returning it to normal operation.