Lennox Air Conditioner Error Code 5

Pressure switch opens after compressor has run for more than two minutes, may indicate improper charge or coil obstruction.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 5 error code actually means

Your Lennox air conditioner started running normally but then detected a refrigerant pressure problem after about two minutes of operation and shut itself down to prevent damage. This usually means the system is low on refrigerant or one of the coils is dirty and blocked. A technician will need to inspect the system to find the cause before it can be safely restarted.

Diagnostic procedure

The full 5 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for low system charge; check for improper charge or coil obstruction.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Dirty or blocked condenser coil
  3. 3Dirty or iced evaporator coil
  4. 4Faulty pressure switch
  5. 5Restricted or failed metering device

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5

What does 5 mean on a Lennox air_conditioner?
Error code 5 means the pressure switch opened after the compressor had been running for more than two minutes. This tells the system that refrigerant pressures moved outside of safe operating limits during a run cycle. The most likely causes are low refrigerant charge or a blocked coil restricting airflow. The system shuts down to protect the compressor from running under damaging conditions.
Is it safe to keep running my Lennox AC when error code 5 appears?
No, you should not continue attempting to operate the system when this code is active. Running the compressor with low refrigerant charge can cause serious compressor damage due to inadequate lubrication and cooling of the compressor internals. The system is shutting down intentionally to prevent this damage, and repeated restarts without resolving the underlying cause can shorten the life of the compressor significantly.
How much does it cost to repair a Lennox air conditioner showing error code 5?
Repair costs vary considerably depending on the root cause. A condenser coil cleaning is typically a lower-cost service call in the range of $75 to $200. If the system needs refrigerant, expect to pay for the service call plus the cost of refrigerant, which can range from $150 to $600 or more depending on refrigerant type and the amount needed. If there is a refrigerant leak requiring repair or a failed component such as a pressure switch or metering device, costs can range from $200 to $800 or higher depending on parts and labor in your area.
Can I fix error code 5 on my Lennox air conditioner myself?
Some portions of the diagnosis are DIY-friendly, such as inspecting and cleaning the outdoor condenser coil for debris or checking that the indoor air filter is clean and unrestricted. However, checking refrigerant charge and repairing refrigerant leaks requires EPA Section 608 certification and proper gauging equipment, so those steps must be handled by a licensed HVAC technician.
Will resetting the system clear error code 5?
Resetting the unit may temporarily clear the fault and allow the system to attempt another cycle, but the error will return if the underlying cause has not been addressed. If the issue is low refrigerant or a coil obstruction, the pressure switch will open again after the compressor runs for a couple of minutes. A reset is useful for confirming the fault is repeatable, but it is not a repair.