Lennox Air Conditioner Error Codes

51 error codes for Lennox air conditioner models. Each links to the full diagnostic procedure from the service manual.

MyPros+ Max

Get the full diagnostic procedure for any Lennox air conditioner error code.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts
  • Verified part numbers when replacement is required
Get started

$29/month · Cancel anytime · Or $9.95 3-day pass

E345The 'O' relay on the outdoor board has failedE409Outdoor control secondary voltage is 18VAC or less; after 10 minutes, operation…E410The outdoor unit low pressure switch has closed indicating unit pressure is…E411The low pressure switch has opened 5 times within one hour, locking out the…E412The outdoor unit high pressure switch has opened indicating unit pressure is…E413The high pressure switch has opened 5 times within one hour, locking out the…E416The outdoor coil sensor has malfunctioned (open, shorted, or out of range)…E422Compressor top cap switch exceeding thermal limit.E423The inverter has detected a circuit problem (inverter code 40).E424The liquid line temperature sensor has malfunctioned (open or shorted).E425Outdoor control has increased minimum compressor speed to allow for proper oil…E426Excessive inverter alarmsE427The inverter has detected a DC peak fault condition (55A or higher), causing…E428The inverter has detected a high main input current condition (inverter code…E429DC link power in inverter does not rise above threshold (180 VDC for 2/3-ton…E430Compressor start failure detected by inverter (inverter code 26).E431PFC detected an over-current condition of 100A (inverter code 27), indicating…E432The inverter has detected a DC link high voltage conditionE433The inverter has detected a compressor over-current condition (peak phase…E434Outdoor control has lost communications with the inverter for greater than 3…E435Inverter internal error (inverter code 60); outdoor control cycles power to the…E436Inverter heat sink temperature exceeded limit (inverter code 62).E437Heat sink temperature sensor fault has occurredE438The inverter has detected a PFC over current condition caused by a high load…E439Compressor slowdown due to high input currentE440Heat sink temperature is approaching limit (inverter code 13); compressor speed…E441Compressor slowdown due to high compressor currentE442The top cap switch has opened five times within one hour, locking out the…E443Incorrect appliance unit size code selected.E600Compressor has been cycled OFF on utility load shedding.E601Outdoor unit has been cycled OFF on low temperature protection

Start diagnosing faster today.

$29/month · Cancel anytime · Or $9.95 3-day pass

Get started