Lennox Air Conditioner Error Code E427

The inverter has detected a DC peak fault condition (55A or higher), causing compressor and fan to stop (inverter code 21).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E427 error code actually means

Your Lennox air conditioner detected a dangerous spike in electrical current inside its inverter control system, so it shut itself down to prevent damage to the compressor and electronics. This usually happens because of a refrigerant problem, a blocked outdoor fan, or a compressor that is struggling or seized. The system will not restart safely until the underlying issue is found and fixed.

Diagnostic procedure

The full E427 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for high pressure, condenser fan failure, locked compressor rotor or overcharge. Disconnect power to outdoor unit and restart.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E427 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E427

Ranked by how often they cause this code
  1. 1Condenser Fan Failure or Blockage
  2. 2High Refrigerant Head Pressure
  3. 3Refrigerant Overcharge
  4. 4Locked or Seized Compressor Rotor
  5. 5Damaged Inverter Module

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E427

What does E427 mean on a Lennox air_conditioner?
E427 indicates the inverter has detected a DC peak current fault at or above 55 amperes, which is logged as inverter code 21. When this condition occurs, the inverter immediately shuts down both the compressor and outdoor condenser fan to protect the system. The fault is typically caused by high refrigerant pressure, a failing condenser fan, an overcharged system, or a seized compressor rotor.
Is it safe to keep running my Lennox AC when E427 appears?
The system automatically shuts down the compressor and fan when E427 is triggered, so it will not continue running in a dangerous state on its own. You should not attempt to repeatedly force restarts without diagnosing the cause, as doing so could worsen damage to the compressor or inverter module. Leave the unit off until the fault is properly diagnosed and resolved.
How much does it cost to repair an E427 fault on a Lennox air conditioner?
Repair cost varies widely depending on the root cause. Clearing a blocked condenser coil or replacing a condenser fan motor typically runs in the range of $150 to $450 including labor. Correcting a refrigerant overcharge may cost $100 to $300. Compressor replacement is the most expensive scenario, generally ranging from $1,200 to $2,500 or more depending on the unit size and refrigerant type. Inverter module replacement also falls in the higher cost range, typically $600 to $1,500.
Will resetting the unit clear the E427 fault?
Disconnecting power to the outdoor unit and performing a restart is the recommended first step, and the unit may temporarily resume operation if the fault condition was transient. However, if the underlying cause such as high head pressure, a bad condenser fan, or a seized compressor is still present, the E427 fault will return quickly after restart. A reset alone does not fix the root problem.
How do I fix an E427 error on my Lennox air conditioner?
Start by disconnecting power to the outdoor unit and inspecting the condenser fan and coil for blockage or motor failure. A licensed technician should connect refrigerant gauges to check for overcharge or abnormally high head pressure. If those checks are normal, the compressor should be tested for a locked rotor condition. Any failed components, whether the fan motor, refrigerant charge, or compressor, must be corrected before the system can operate safely.