mypros+
Model reference

Lennox XC20-048-230A

Air Conditioner

1 document38 error codes6 service modes

Available documentation

Service Manual

  • INSTALLATION AND SERVICE PROCEDURE - Elite Series® XC20 Units77 pg
    Covers this model
MyPros+ Max

Diagnose your Lennox XC20-048-230A.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (38)

CodeMeaning
E105The outdoor control has lost communication with either the thermostat or indoor…E120There is a delay in the outdoor unit responding to the system.E124The iComfort Wi-Fi thermostat has lost communication with the outdoor unit for…E125There is a hardware problem with the outdoor control.E131The outdoor unit control parameters are corrupted.E132Internal software error on the outdoor control.E180The outdoor unit ambient temperature sensor has malfunctioned; outdoor unit…E345The 'O' relay on the outdoor board has failedE409Outdoor control secondary voltage is 18VAC or less; after 10 minutes, operation…E410The outdoor unit low pressure switch has closed indicating unit pressure is…E411The low pressure switch has opened 5 times within one hour, locking out the…E412The outdoor unit high pressure switch has opened indicating unit pressure is…E413The high pressure switch has opened 5 times within one hour, locking out the…E416The outdoor coil sensor has malfunctioned (open, shorted, or out of range)…E422Compressor top cap switch exceeding thermal limit.E423The inverter has detected a circuit problem (inverter code 40).E424The liquid line temperature sensor has malfunctioned (open or shorted).E425Outdoor control has increased minimum compressor speed to allow for proper oil…E426Excessive inverter alarmsE427The inverter has detected a DC peak fault condition (55A or higher), causing…E428The inverter has detected a high main input current condition.E429DC link power in inverter does not rise above threshold (180 VDC for 2/3-ton…E430Compressor start failure detected by inverter (inverter code 26).E431PFC detected an over-current condition of 100A (inverter code 27), indicating…E432The inverter has detected a DC link high voltage condition (greater than…E433The inverter has detected a compressor over-current condition (peak phase…E434Outdoor control has lost communications with the inverter for greater than 3…E435Inverter internal error (inverter code 60); outdoor control cycles power to the…E436Inverter heat sink temperature exceeded limit (inverter code 62).E437Heat sink temperature sensor fault has occurred
View all 38 error codes

Service modes (6)

  • Diagnostic Mode1
  • Display Configuration Mode (Enable coil and liquid line temperature display)1
  • Error Code Recall Mode1
  • Outdoor Fan Test Mode1
  • Pump Down Mode1
  • Unit Selection Code Programming1

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass