Lennox Air Conditioner Error Code E423

The inverter has detected a circuit problem (inverter code 40).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E423 error code actually means

Your Lennox air conditioner's internal inverter, which controls how the compressor runs, has detected a problem with its own circuitry and shut the system down to prevent damage. If this happens 10 times in one hour, the unit will lock itself out completely and will need to be manually restarted by cutting power. A technician will need to inspect the inverter and its electrical connections to resolve this issue.

Diagnostic procedure

The full E423 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Disconnect power to outdoor unit and restart. Control locks out after 10 strikes within an hour.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E423 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E423

Ranked by how often they cause this code
  1. 1Failed or degraded inverter module
  2. 2Voltage irregularities at the inverter input
  3. 3Overheating of the inverter power module
  4. 4Loose or corroded power connections to the inverter
  5. 5Transient power surge or grid disturbance

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E423

What does E423 mean on a Lennox air_conditioner?
E423 means the inverter module in your Lennox outdoor unit has detected an internal circuit problem, identified internally as inverter code 40. The inverter controls compressor speed and shuts down when it detects a fault to protect the system. This code can result from a failed inverter, power supply issues, overheating, or poor electrical connections. A technician should inspect the inverter and its power supply to determine the root cause.
Is it safe to run my Lennox AC when E423 is showing?
The unit is designed to shut itself down when E423 is triggered, so continued operation is automatically prevented. Attempting to repeatedly reset and force the unit to run with an active inverter fault risks permanent damage to the inverter or the compressor. It is best to leave the unit off and schedule a technician inspection promptly.
How much does it cost to repair a Lennox E423 inverter fault?
Repair costs vary significantly depending on the root cause. If the issue is simply a loose connection or a one-time power surge, costs may be limited to a diagnostic service call fee, typically in the range of $75 to $150. If the inverter module itself requires replacement, parts and labor costs can range from $400 to over $1,200 depending on the specific unit model and regional labor rates. A technician diagnosis is necessary before accurate cost estimates can be provided.
Can I fix E423 on my Lennox air conditioner myself?
The first step you can safely take is disconnecting power to the outdoor unit, waiting a few minutes, and restoring power to see if the error clears. However, if the fault returns, diagnosing and repairing inverter circuit problems involves high-voltage components and requires a qualified HVAC technician. Attempting to test or replace the inverter without proper training and equipment is not recommended.
Will resetting the power clear the E423 error on a Lennox unit?
A power reset by disconnecting the outdoor unit and restoring it is the recommended first diagnostic step and may clear the error if it was caused by a transient power disturbance. However, if the fault is due to a hardware problem such as a failing inverter or wiring issue, the code will return after reset. Importantly, if the error triggers 10 times within one hour, the control locks out the unit and a power reset becomes required just to restore basic operation.