The inverter has detected a high main input current condition (inverter code 22).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E428 error code actually means

Your Lennox air conditioner detected that the electrical current flowing into its compressor control board was too high, so it shut down to protect itself from damage. This is often caused by a blocked or dirty outdoor unit, a broken outdoor fan, or too much refrigerant in the system. A technician will need to check the outdoor unit conditions before restarting the system.

Diagnostic procedure

The full E428 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for high pressure, condenser fan failure or overcharge. Disconnect power to outdoor unit and restart.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E428 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E428

Ranked by how often they cause this code
  1. 1Condenser Fan Failure
  2. 2High Head Pressure from Condenser Coil Blockage
  3. 3Refrigerant Overcharge
  4. 4Inverter Module Fault
  5. 5Power Supply Voltage Anomaly

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E428

What does E428 mean on a Lennox air_conditioner?
E428 means the inverter drive in the outdoor unit has detected a high main input current condition, which it logs as inverter code 22. The inverter shuts down to protect the compressor and itself from damage caused by excessive electrical current. This fault is most often triggered by high refrigerant pressure, a failed condenser fan, or an overcharged system.
Is it safe to keep running my Lennox AC with an E428 error?
No. The inverter shuts the system down when E428 occurs specifically to prevent compressor and drive board damage from overcurrent stress. Repeatedly forcing restarts without identifying and correcting the underlying cause can lead to compressor failure or inverter board damage, which are significantly more expensive repairs. Leave the unit off until the root cause has been addressed.
How much does it cost to repair an E428 error on a Lennox air conditioner?
Repair costs vary widely depending on the cause. Cleaning a blocked condenser coil is typically the least expensive fix, often in the range of $100 to $250 for a service call. Replacing a condenser fan motor generally runs $200 to $500 including parts and labor. Correcting a refrigerant overcharge involves recovering and recharging the system, which can range from $150 to $400. Replacing a failed inverter module is the most costly scenario, often ranging from $500 to $1,200 or more depending on the model.
Can I fix E428 myself or do I need a technician?
A homeowner can safely check that the outdoor condenser fan is spinning and that the outdoor unit is not blocked by debris, and can perform a power reset by shutting off the outdoor disconnect for several minutes. However, checking refrigerant pressures, diagnosing a failed fan motor, and correcting an overcharge all require a licensed HVAC technician with proper equipment. If the fault returns after a reset and the unit appears clear of obstructions, professional service is necessary.
Will resetting the power clear the E428 fault on a Lennox unit?
Disconnecting power to the outdoor unit and restarting is the recommended first step and may clear the fault temporarily if the triggering condition was transient. However, if the underlying cause such as a failed condenser fan, high pressure, or overcharge is still present, the fault will return shortly after restart. A power reset should always be combined with a physical inspection of the outdoor unit before powering back on.