Lennox Air Conditioner Error Code E413

The high pressure switch has opened 5 times within one hour, locking out the outdoor unit.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E413 error code actually means

Your Lennox air conditioner shut itself off because it detected dangerously high pressure inside the system five times in one hour and locked out to prevent serious damage. This is a protective feature, not a random glitch, and something is causing the system to run at pressures higher than it should. A technician needs to find and fix the underlying problem before the system can safely run again.

Diagnostic procedure

The full E413 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Confirm system is properly charged with refrigerant. Check condenser fan motor, clogged TXV, blockage to indoor unit blower motor, stuck reversing valve or clogged refrigerant filter. Clear after a power reset.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E413 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E413

Ranked by how often they cause this code
  1. 1Condenser fan motor failure or reduced airflow
  2. 2Refrigerant overcharge
  3. 3Clogged or malfunctioning TXV
  4. 4Blocked indoor blower motor or coil
  5. 5Stuck reversing valve (heat pump models)

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E413

What does E413 mean on a Lennox air_conditioner?
E413 means the high pressure switch in the refrigerant circuit has opened five times within one hour, and the outdoor unit has locked out to prevent compressor damage. The high pressure switch trips when discharge pressure exceeds a safe operating limit. Five trips in a short window indicate a persistent problem rather than a one-time event. A power reset will clear the lockout, but the fault will return unless the root cause is corrected.
Is it safe to run my Lennox AC when it shows E413?
The E413 lockout is a safety feature designed to prevent the compressor from being damaged by sustained high pressure operation. Running the system without addressing the fault risks compressor failure, which is the most expensive component in the refrigerant circuit. It is best to leave the system off and have a technician inspect it before resuming operation.
What should a technician check first when diagnosing E413 on a Lennox air conditioner?
The first step is to connect refrigerant gauges and confirm the system is properly charged, since both undercharge and overcharge can cause high pressure faults. From there, the technician should inspect the condenser fan motor for correct operation, check the indoor blower motor and coil for blockages, evaluate TXV function through superheat measurements, and inspect the refrigerant filter for restriction. On heat pump models, the reversing valve should also be tested.
Will resetting the power clear the E413 fault on my Lennox unit?
Yes, cycling power to the system will clear the E413 lockout and allow the outdoor unit to restart. However, if the underlying cause is not corrected, the high pressure switch will trip again and E413 will return, potentially within minutes. A power reset should only be used after diagnosing and resolving the condition that caused the repeated high pressure trips.
How much does it cost to repair a Lennox E413 error?
Repair costs depend entirely on the root cause. A refrigerant charge adjustment or a dirty coil cleaning may cost between $100 and $300. A TXV replacement or condenser fan motor replacement typically runs between $250 and $600 including labor. A reversing valve replacement or compressor repair, if damage has already occurred, can range from $600 to over $1,500 depending on parts and labor in your area.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass