What the E426 error code actually means

Your Lennox air conditioner shut itself down because it detected the same internal problem happening ten times within one hour, which is a sign that something is consistently wrong with how the system is operating. This is a safety feature to protect the equipment from further damage. A technician will need to investigate the refrigerant levels, fans, and other components to find and fix the underlying issue before the unit will run normally again.

Diagnostic procedure

The full E426 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Review history of alarms. Check condenser fan motor, TXV, indoor unit blower motor, over-charge, undercharge, or clogged refrigerant filter. Disconnect power to outdoor unit and restart.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E426 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E426

Ranked by how often they cause this code
  1. 1Incorrect refrigerant charge
  2. 2Condenser fan motor failure or degradation
  3. 3Faulty or restricted TXV
  4. 4Indoor unit blower motor issue
  5. 5Clogged refrigerant filter or drier

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E426

What does E426 mean on a Lennox air_conditioner?
E426 means the inverter control has locked out the system after recording ten inverter fault events within one hour. This is a protective lockout, not a single isolated failure. The code indicates that an underlying system condition such as incorrect refrigerant charge, a failed fan motor, or a restricted TXV has been causing repeated inverter alarms until the threshold was reached.
Will resetting the unit permanently clear the E426 code?
A power reset will clear the active lockout and allow the system to restart, but it will not fix whatever is driving the repeated inverter alarms. If the root cause such as low refrigerant, a failed condenser fan, or a restricted TXV is not repaired, the system will reach ten faults again within an hour and lock out again. A permanent resolution requires diagnosing and correcting the underlying system problem.
How much does it cost to repair a Lennox E426 error?
Repair costs vary widely depending on the root cause. A refrigerant charge correction typically runs in the range of $150 to $400 depending on the amount of refrigerant involved and whether a leak repair is needed. Component replacements such as a condenser fan motor or TXV can range from $300 to $800 or more including labor. A diagnostic visit from a certified HVAC technician is generally required first to identify which component or condition is responsible.
Can I reset a Lennox E426 error code myself?
You can attempt a reset by disconnecting power to the outdoor unit and then restoring it, which is the first recommended step. However, if the underlying cause is not corrected, the unit will accumulate ten faults again and lock out a second time. Before resetting, review the alarm history on the control board so you understand which specific fault has been repeating.
Is it safe to run my Lennox air conditioner when it shows E426?
The E426 lockout prevents the system from running, which is itself a protective state. You should not attempt to repeatedly reset and restart the unit without diagnosing the cause, as doing so can accelerate wear on the compressor and inverter drive components. Have a qualified technician review the alarm history and perform a full system inspection before returning the unit to regular operation.