Lennox Furnace Error Code DS1 Alternating Fast Flash / DS2 Alternating Fast Flash

During ignitor warm-up period only

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS1 Alternating Fast Flash / DS2 Alternating Fast Flash error code actually means

Your Lennox furnace is flashing this error because it tried to heat up the ignitor to light the burner but something went wrong in that process. The most likely culprits are a burned-out ignitor, a loose ground wire, or low voltage coming from your electrical supply. A technician will need to check the wiring and test the ignitor to determine the exact cause.

Diagnostic procedure

The full DS1 Alternating Fast Flash / DS2 Alternating Fast Flash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check main ground, ignitor resistance, and line voltage.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS1 Alternating Fast Flash / DS2 Alternating Fast Flash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS1 Alternating Fast Flash / DS2 Alternating Fast Flash

Ranked by how often they cause this code
  1. 1Failed hot surface ignitor
  2. 2Improper or loose main ground connection
  3. 3Line voltage below 75 volts AC
  4. 4Open ignitor wiring or connector

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS1 Alternating Fast Flash / DS2 Alternating Fast Flash

What does DS1 Alternating Fast Flash / DS2 Alternating Fast Flash mean on a Lennox furnace?
This code means the furnace detected a problem during the ignitor warm-up period, which is the stage just before the gas valve opens. The board is flagging one of three possible issues: an improper main ground, a broken or open ignitor circuit, or incoming line voltage below 75 volts AC. The alternating fast flash pattern on both diagnostic LEDs is specific to this warm-up stage fault, which helps distinguish it from faults that occur later in the ignition sequence.
How do I fix the DS1 and DS2 alternating fast flash error on my Lennox furnace?
Start by checking the three items the code points to: the main ground connection, the ignitor resistance, and the incoming line voltage. Use a multimeter to test ignitor resistance and look for an open circuit reading, which means the ignitor needs replacement. Verify the ground wire is securely attached at the furnace chassis, and confirm line voltage at the furnace is at least 75 volts AC while the unit is calling for heat. If voltage is low, an electrician may need to evaluate the supply circuit.
How much does it cost to repair a Lennox furnace showing this error code?
If the ignitor is the cause, replacement parts and labor typically range from $150 to $350 depending on the specific model and local labor rates. Wiring or ground connection repairs tend to fall on the lower end of that range since no parts are usually required. If low line voltage is the culprit, electrical panel or circuit work by a licensed electrician could add additional cost. Getting a diagnostic visit from a technician will clarify exactly which component is at fault before committing to a repair cost.
Can I reset my Lennox furnace to clear this error code?
Resetting the furnace by cycling the power may temporarily clear the code and allow another ignition attempt, but the error will return if the underlying problem is not corrected. A failed ignitor, bad ground, or low voltage condition will cause the fault to repeat each time the furnace tries to light. Resetting is useful for confirming the fault is consistent, but it is not a fix.
Is it safe to run my furnace when it is showing this error?
The furnace will not produce heat while this fault is active because the ignitor is not functioning correctly, which also means no gas is being released. This makes it a non-heating failure rather than a safety emergency in most cases. However, the furnace should not be left to cycle repeatedly without addressing the cause, as persistent retry attempts can stress other components. Contact a qualified technician to diagnose and correct the fault before relying on the furnace for heat.