mypros+
Model reference

Lennox G61MPV-36B-070

Furnace

1 document31 error codes2 service modes

Available documentation

Service Manual

  • G61MPV Service Literature103 pg
    Covers this model
MyPros+ Max

Diagnose your Lennox G61MPV-36B-070.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (31)

CodeMeaning
1+2Low flame current during run mode (Board 100870).1+3Flame sensed out of sequence2+3Low pressure switch failed open (Board 100870).2+4Low pressure switch failed closed (Board 100870).2+5High pressure switch failed open (Board 100870).2+6High pressure switch failed closed (Board 100870).2+7Low pressure switch opened during ignition trial or heating demand (Board…3+1Limit switch open (Board 100870).4+1Watchguard4+2Watchguard4+3Watchguard4+5Watchguard4+6Watchguard4+7Ignitor circuit fault4+8Low line voltage (Board 100870).5+1Hard lockout5+2Control failed self check, internal error; control will restart if error…5+3No earth ground; control will restart if error recovers (Board 100870).5+4Reversed line voltage polarity; control will restart if the error recovers…5+6Low secondary (24VAC) voltage (Board 100870).DS1 Alternating Fast Flash / DS2 Alternating Fast FlashDuring ignitor warm-up period onlyDS1 Alternating Slow Flash / DS2 Alternating Slow FlashWatchguardDS1 Fast Flash / DS2 Fast FlashNormal operationDS1 Fast Flash / DS2 Slow FlashMain power polarity reversedDS1 OFF / DS2 Fast FlashHigh prove switch open; or blocked inlet/exhaust vent; or high prove switch…DS1 OFF / DS2 ONFlame sensed without gas valve energized.DS1 OFF / DS2 Slow FlashLow prove switch open; or blocked inlet/exhaust vent; or low prove switch…DS1 ON / DS2 ONCircuit board failure or control wired incorrectlyDS1 Slow Flash / DS2 Fast FlashLow flame signal; measures below 0.23 microAmpsDS1 Slow Flash / DS2 ONPrimary, secondary, backup secondary or rollout limit switch open; limits must…
View all 31 error codes

Service modes (2)

  • ICM-2 blower motor checkout (24V source method)["Disconnect power to unit.","Disconnect plug J46 from P46 located on the blower control…
  • ICM-2 blower motor checkout (battery method)["Disconnect power to unit.","Disconnect plug J46 from P46 located on the blower control…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass