What the DS1 Alternating Slow Flash / DS2 Alternating Slow Flash error code actually means

Your Lennox furnace shut itself down as a safety measure because it detected a problem with the ignition, the burner flame, or the airflow through the system. This could mean the burners are not lighting properly, the furnace is overheating, or the venting system is not working correctly. The furnace will not restart on its own until the underlying problem is identified and resolved.

Diagnostic procedure

The full DS1 Alternating Slow Flash / DS2 Alternating Slow Flash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check gas supply, ignitor, flame sensor, prove switches, and limit switches.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS1 Alternating Slow Flash / DS2 Alternating Slow Flash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS1 Alternating Slow Flash / DS2 Alternating Slow Flash

Ranked by how often they cause this code
  1. 1Dirty or Failing Flame Sensor
  2. 2Weak or Failed Hot Surface Ignitor
  3. 3Restricted Airflow Causing Limit Switch Fault
  4. 4Pressure Switch or Draft Inducer Issue
  5. 5Inadequate Gas Supply

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS1 Alternating Slow Flash / DS2 Alternating Slow Flash

What does DS1 Alternating Slow Flash / DS2 Alternating Slow Flash mean on a Lennox furnace?
This alternating slow flash pattern between DS1 and DS2 indicates a Watchguard lockout condition on the Lennox furnace control board. It activates when the burners fail to ignite, when a limit switch stays open for more than 3 minutes, when flame sense is lost 5 times in one heating cycle, or when a pressure switch opens 5 times in one cycle. The furnace will not attempt to restart until the fault is cleared. Diagnosing the specific trigger requires checking the gas supply, ignitor, flame sensor, limit switches, and pressure switches.
Is it safe to run my furnace when it shows this error?
The Watchguard lockout is a built-in safety function, so the furnace has already shut itself down and is not operating while in lockout. It is safe to investigate the cause, but you should not attempt to bypass the safety controls or force repeated manual resets without identifying the problem. If the fault is related to a limit switch staying open, this can indicate the heat exchanger is overheating, which should be addressed promptly to avoid damage to the furnace.
What should I check first when my Lennox furnace shows this fault?
Start by confirming the gas supply is on and the shutoff valve is fully open, then check the air filter and make sure all supply and return vents are unobstructed. Next, inspect the flame sensor rod for oxidation or buildup and check visible pressure switch hoses for cracks or disconnections. If the basic checks do not reveal an obvious problem, a technician with diagnostic tools can measure ignitor resistance, check pressure switch operation with a manometer, and evaluate blower motor performance to pinpoint the cause.
Can I reset my Lennox furnace to clear this error code?
You can reset the furnace by cycling the power off and back on, which will clear the Watchguard lockout and allow the furnace to attempt another ignition sequence. However, if the underlying problem is not corrected first, the furnace will go through its ignition trials again, fail under the same conditions, and return to lockout. Resetting without diagnosing and repairing the root cause is not a lasting solution and repeated lockouts can indicate a progressively worsening component failure.
How much does it cost to repair a Lennox furnace showing this error?
Repair costs vary significantly depending on the root cause. Cleaning a flame sensor is a low-cost repair, often falling in the range of $80 to $150 for a service call if done by a technician. Replacing a hot surface ignitor typically costs between $150 and $300 including parts and labor. More extensive repairs such as a failed draft inducer motor or a damaged pressure switch assembly can range from $250 to $600 or more depending on the specific components and local labor rates.