What the DS2:FastFlash / DS1:OFF error code actually means

Your Lennox heat pump has shut itself down because the sensor that monitors temperature at the compressor kept sending bad readings five times in a row during one run cycle. The system locked out to protect the compressor from running without reliable temperature data. A technician will need to inspect or replace the sensor and its wiring to get the unit running reliably again.

Diagnostic procedure

The full DS2:FastFlash / DS1:OFF procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Cycle OFF 24V power to board or short TEST pins 1-2 seconds to reset. Check/replace discharge sensor harness.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2:FastFlash / DS1:OFF procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2:FastFlash / DS1:OFF

Ranked by how often they cause this code
  1. 1Faulty or failed discharge temperature sensor
  2. 2Damaged or chafed sensor harness wiring
  3. 3Loose or corroded connector pins
  4. 4Sensor improperly seated or displaced from mounting location
  5. 5Control board input circuit failure

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2:FastFlash / DS1:OFF

What does DS2:FastFlash / DS1:OFF mean on a Lennox heat pump?
This code indicates a discharge sensor lockout. The control board recorded five out-of-range faults from the discharge line temperature sensor during a single Y1 demand cycle and locked out the system to protect the compressor. The DS2 LED flashes rapidly while DS1 remains off to signal this specific fault condition. The underlying cause is typically a failed sensor, damaged harness wiring, or a poor electrical connection at the sensor connector or board.
Is it safe to keep resetting and running the heat pump with this fault?
Continuing to reset and operate the unit without correcting the sensor fault is not recommended. The discharge sensor is a primary protection input for the compressor, and running without reliable discharge temperature data risks undetected overheating. Repeated compressor overtemperature events can cause premature compressor failure, which is a significantly more expensive repair than replacing a sensor or harness.
Can a homeowner diagnose or fix this fault themselves?
A knowledgeable homeowner can safely perform the board reset procedure by cycling the 24V thermostat power and can visually inspect the sensor harness for obvious damage or loose connectors. However, accurately testing sensor resistance against temperature specifications and working near refrigerant lines and high-voltage compressor terminals requires proper tools and training. Full diagnosis and any component replacement is best handled by a qualified HVAC technician.
Will resetting the board clear this fault permanently?
A reset, either by cycling 24V control power or by shorting the TEST pins for 1 to 2 seconds, will clear the lockout and allow the unit to restart. However, if the discharge sensor or its wiring is not repaired or replaced, the board will accumulate five new range faults during the next demand cycle and lock out again. The reset only clears the stored fault; it does not fix the root cause.
How much does it typically cost to repair this fault?
If the fix is limited to reseating a connector or repairing a chafed wire, the cost is primarily labor, typically in the range of $75 to $200 depending on local rates. Replacing the discharge temperature sensor itself usually adds $20 to $80 for the part. If the control board's sensor input circuit has failed, board replacement can push the total repair cost into the $300 to $700 range including parts and labor.