Lennox Heat Pump Error Code DS2:SimultaneousFastFlash / DS1:SimultaneousFastFlash

Ambient sensor problem

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS2:SimultaneousFastFlash / DS1:SimultaneousFastFlash error code actually means

Your Lennox heat pump is showing this error because the outdoor temperature sensor is not working correctly. The sensor may be broken, have a wiring problem, or be reading temperatures that seem impossible to the control board. Until the sensor is repaired, the system will still run but will defrost on a fixed timer schedule instead of defrosting only when needed.

Diagnostic procedure

The full DS2:SimultaneousFastFlash / DS1:SimultaneousFastFlash procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check ambient sensor resistance at pins 3 & 4 (Black wire); replace sensor harness if shorted or open.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2:SimultaneousFastFlash / DS1:SimultaneousFastFlash procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2:SimultaneousFastFlash / DS1:SimultaneousFastFlash

Ranked by how often they cause this code
  1. 1Failed ambient thermistor
  2. 2Damaged or shorted sensor harness
  3. 3Loose or corroded connector at pins 3 and 4
  4. 4Sensor exposed to extreme or abnormal ambient conditions
  5. 5Defective control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2:SimultaneousFastFlash / DS1:SimultaneousFastFlash

What does DS2:SimultaneousFastFlash / DS1:SimultaneousFastFlash mean on a Lennox heat pump?
This code means the control board has detected a problem with the ambient temperature sensor on the outdoor unit. The sensor has been identified as open, shorted, or reading a temperature value outside the acceptable range. The system responds by reverting to a fixed time/temperature defrost schedule instead of demand-based defrost. Both diagnostic LEDs flashing simultaneously at a fast rate is the visual indicator for this specific fault.
Will resetting the Lennox heat pump clear this error code?
Resetting the unit by cycling power may temporarily clear the displayed fault, but the error will return as soon as the board attempts to read the ambient sensor again and receives an invalid signal. A reset does not correct the underlying wiring or sensor problem. Proper diagnosis and repair of the sensor circuit are required to permanently clear this fault.
How much does it cost to repair the DS2/DS1 ambient sensor fault on a Lennox heat pump?
Repair costs vary depending on whether the issue is limited to the sensor harness, the thermistor itself, or the control board. A sensor or harness replacement is typically the least expensive repair, with parts and labor generally ranging from $75 to $250 depending on your location and service provider. If the control board requires replacement, costs can range from $300 to $700 or more. Getting a diagnosis from a qualified HVAC technician before purchasing parts is recommended to avoid unnecessary expenses.
How do I fix the DS2/DS1 simultaneous fast flash error on my Lennox heat pump?
Start by measuring resistance at pins 3 and 4 on the control board where the Black ambient sensor wire connects. Disconnect the harness and test resistance across the sensor leads: an open or near-zero reading points to a failed sensor or damaged harness. Inspect the harness along its entire length for chafing, pinching, or corroded terminals. Replace the sensor harness if shorted or open, or replace the ambient thermistor if the harness tests good but the sensor does not.
Is it safe to run my Lennox heat pump with this error active?
The unit will continue to operate with this error present because the control board automatically switches to a time/temperature defrost mode as a fallback. However, running in this mode reduces efficiency and may lead to inadequate or overly frequent defrost cycles depending on actual outdoor conditions. It is advisable to schedule a repair promptly to restore proper defrost control and protect the compressor from operating with excessive ice buildup on the outdoor coil.