Lennox Heat Pump Error Code DS2:SlowFlash / DS1:OFF

High pressure fault

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the DS2:SlowFlash / DS1:OFF error code actually means

Your Lennox heat pump shut itself off because it detected refrigerant pressure that was too high inside the system, which can damage the compressor if ignored. This is the first warning strike and the system may try to restart on its own, but repeated occurrences will cause a full lockout. A technician should inspect the unit for blocked airflow, dirty coils, or a refrigerant charge issue before the problem gets worse.

Diagnostic procedure

The full DS2:SlowFlash / DS1:OFF procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for restricted airflow, improper refrigerant charge, improper metering device, or incorrect sensor location/connection.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2:SlowFlash / DS1:OFF procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2:SlowFlash / DS1:OFF

Ranked by how often they cause this code
  1. 1Restricted airflow across outdoor or indoor coil
  2. 2Improper refrigerant charge
  3. 3Faulty or improperly sized metering device
  4. 4Incorrect high pressure sensor location or wiring
  5. 5Failed condenser or air handler fan motor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2:SlowFlash / DS1:OFF

What does DS2:SlowFlash / DS1:OFF mean on a Lennox heat_pump?
This code indicates the high pressure switch has tripped and logged one strike toward a lockout condition. The high pressure switch opens when refrigerant discharge pressure exceeds a safe operating threshold, shutting down the compressor to prevent damage. The system may attempt to restart automatically, but additional trips within the monitoring window will accumulate strikes and eventually cause a full lockout. A technician should diagnose the root cause before more strikes occur.
Is it safe to keep running my heat pump with this error?
The system is designed to protect itself by shutting the compressor down when this fault occurs, so immediate compressor damage is unlikely as long as the safety circuit is functioning correctly. However, continuing to operate the unit without addressing the root cause increases the risk of compressor failure over time, especially as additional strikes accumulate toward a full lockout. It is best to have the fault diagnosed and corrected promptly to avoid more costly repairs.
How much does it cost to repair a high pressure fault on a Lennox heat pump?
Repair costs vary depending on the cause. Cleaning a dirty condenser coil or replacing an air filter is relatively inexpensive, typically in the range of $75 to $200 for a service call. Refrigerant adjustments, metering device replacement, or fan motor repairs can range from $200 to $600 or more depending on parts and labor rates in your area. A compressor replacement, if delayed diagnosis leads to compressor failure, can cost $1,000 to $2,500 or higher.
Can I fix a DS2:SlowFlash / DS1:OFF fault myself?
Some causes, such as a dirty outdoor coil, a clogged air filter, or debris blocking the outdoor unit, can be addressed by a homeowner without special tools. However, diagnosing refrigerant charge issues, verifying metering device operation, and checking pressure switch wiring require manifold gauges and HVAC training. If the basic airflow checks do not resolve the fault, a licensed HVAC technician should perform the full refrigerant circuit inspection.
Will resetting the unit clear this error code?
Resetting the unit may clear the current strike count and allow the system to restart, but it will not correct the underlying condition causing the high pressure fault. If the root cause is not addressed, the fault will recur and additional strikes will be logged until a full lockout is triggered. A reset should only be performed as part of a diagnostic process, not as a substitute for proper repair.