What the DS2:SlowFlash / DS1:ON error code actually means

Your Lennox heat pump has shut down the compressor because the temperature of the refrigerant line leaving the compressor got dangerously high, above 285 degrees Fahrenheit. This is a protective shutdown to prevent damage to the compressor. The system will not restart until the line cools down, and the underlying cause needs to be diagnosed and corrected before it will operate normally again.

Diagnostic procedure

The full DS2:SlowFlash / DS1:ON procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check for restricted airflow, improper charge, improper metering device, or incorrect sensor location. Compressor remains off until discharge temp drops below 225°F (107°C).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock DS2:SlowFlash / DS1:ON procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of DS2:SlowFlash / DS1:ON

Ranked by how often they cause this code
  1. 1Restricted airflow across coils
  2. 2Improper refrigerant charge
  3. 3Malfunctioning or improperly sized metering device
  4. 4Shorted discharge line temperature sensor
  5. 5Incorrect sensor location

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about DS2:SlowFlash / DS1:ON

What does DS2:SlowFlash / DS1:ON mean on a Lennox heat_pump?
This code indicates a discharge line temperature fault. The heat pump's control board detected that the discharge line temperature exceeded 285°F (140°C) during compressor operation, which triggered a protective compressor lockout. The fault can be caused by a shorted temperature sensor or by actual high discharge temperatures resulting from airflow restrictions, refrigerant charge issues, or a faulty metering device. The compressor will not restart until the discharge temperature drops below 225°F (107°C).
Is it safe to keep running my Lennox heat pump when this fault is active?
The control board has already protected the system by locking out the compressor when this fault triggers, so the unit will not run the compressor in a damaging state during the lockout period. However, you should not attempt to repeatedly reset the unit and force it to restart without identifying the root cause. Continued operation under high discharge temperature conditions can degrade compressor lubrication and lead to complete compressor failure.
How much does it cost to repair a Lennox heat pump showing this fault code?
Repair costs vary depending on the root cause. A simple service call to clean coils, check airflow, and verify refrigerant charge might run in the range of $100 to $300. If the discharge line temperature sensor needs replacement, parts and labor could range from $150 to $400. A refrigerant recharge typically adds $150 to $500 depending on refrigerant type and the amount needed. Metering device replacement is more involved and could range from $300 to $700 or more. A compressor replacement, if damage has already occurred, is significantly more expensive.
Can I fix the DS2:SlowFlash / DS1:ON fault myself?
Some portions of the diagnosis are DIY-friendly, such as checking and replacing air filters, clearing debris from the outdoor unit, and confirming airflow is not blocked at supply or return vents. However, diagnosing refrigerant charge, testing the metering device, and replacing the discharge line sensor typically require specialized tools and refrigerant handling certification. It is recommended to contact a licensed HVAC technician for anything beyond basic airflow checks.
Will resetting the heat pump clear the DS2:SlowFlash / DS1:ON fault?
A reset may temporarily clear the fault code and allow the compressor to attempt a restart, but only after the discharge temperature drops below 225°F (107°C). If the underlying cause, such as restricted airflow, low refrigerant charge, or a faulty sensor, is not corrected, the fault will return once the system runs and temperatures rise again. Resetting without diagnosis is not a fix and can lead to repeated fault cycles.