Lennox HVAC Error Code 103

The 24VAC to the air-handler control is lower than the required range of 18 to 30VAC.

SourceLennox CBX40UHV - Service Manual: Installation & Service (HFC-410A)p. 35

Diagnostic procedure

The full 103 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check and correct voltage. Check for additional power-robbing equipment connected to system. May require installation of an additional or larger VA transformer.

SourceLennox CBX40UHV - Service Manual: Installation & Service (HFC-410A)p. 35