mypros+
Error code reference

Lennox HVAC Error Code 205

The indoor blower motor is overheating (motor tripped on internal protector).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 205 error code actually means

Error code 205 means the fan motor that circulates air through your home has gotten too hot and shut itself off as a safety measure. This can happen because the motor is wearing out, there is something blocking airflow like a dirty filter, or the motor is struggling due to a failing part. The system should recover on its own once the motor cools down, but the root cause needs to be found and fixed to prevent it from happening again.

Diagnostic procedure

The full 205 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check motor bearings and amps. Replace if necessary. The alarm/fault clears after blower demand is satisfied.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 205 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 205

Ranked by how often they cause this code
  1. 1Worn or failing motor bearings
  2. 2High amp draw exceeding motor rating
  3. 3Restricted airflow
  4. 4Failing run capacitor
  5. 5End-of-life motor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 205

What does 205 mean on a Lennox hvac?
Error code 205 on a Lennox HVAC system means the indoor blower motor has overheated and tripped its internal thermal protector. The protector is a built-in safety device that shuts the motor down before winding damage can occur. The fault clears automatically once the blower demand is satisfied and the motor cools, but the underlying cause must be diagnosed. Lennox specifies checking motor bearings and amp draw as the first diagnostic step.
Is it safe to run my Lennox system when error code 205 is active?
You should not continue operating the system without addressing the cause of code 205. The internal protector is designed to prevent motor fire and winding damage, and repeated thermal trips accelerate motor deterioration. Running the system while the fault is active or recurring can lead to complete motor failure and, in worst-case scenarios, a fire risk from sustained overheating.
How much does it cost to repair error code 205 on a Lennox system?
Repair cost depends on the root cause. If the fix is simply replacing a clogged filter or clearing an airflow restriction, the cost is minimal, typically under $30 for parts. A run capacitor replacement generally falls in the $75 to $200 range including labor. If the blower motor itself needs to be replaced, costs typically range from $300 to $700 or more depending on the motor specifications and local labor rates.
Will resetting the system clear error code 205?
The fault associated with code 205 clears on its own after the blower demand condition is satisfied, so a manual reset is not required. However, simply waiting for the code to clear does not fix the problem. If the bearing wear, high amp draw, or airflow restriction causing the overheat is not corrected, the motor will trip again during the next run cycle.
How do I fix error code 205 on a Lennox HVAC?
Start by checking the air filter and replacing it if it is dirty, then inspect the return grilles and evaporator coil for blockages. Next, measure the motor's amp draw with a clamp meter and compare it to the nameplate rating. Check the bearings by manually spinning the blower wheel with power off; any stiffness or grinding indicates bearing failure. If bearings are worn, amp draw is high, or the motor trips repeatedly under normal conditions, the motor should be replaced.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass