Lennox HVAC Error Code 351

There is a problem with the air-handler's first stage electric heat (pilot relay contacts did not close or relay coil did not energize).

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 351 error code actually means

Your Lennox heating system is showing that the first stage of electric heat is not turning on properly due to a small internal switch called a relay that is not working as expected. This means your system may not be able to heat your home fully or at all during cold weather. A technician will need to inspect and likely replace that relay or repair the wiring connected to it.

Diagnostic procedure

The full 351 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check relay coil and contacts. The alarm clears after stage 1 relay is detected.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 351 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 351

Ranked by how often they cause this code
  1. 1Failed relay coil
  2. 2Worn or stuck relay contacts
  3. 3Loose or broken wiring at the relay
  4. 4Control board not supplying voltage to relay coil
  5. 5Relay socket or mounting issue

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 351

What does 351 mean on a Lennox hvac?
Error code 351 on a Lennox air handler indicates a problem with the first stage electric heat pilot relay. Either the relay coil did not energize or its contacts did not close when the system called for stage 1 heat. This prevents the first stage heating elements from receiving power. The alarm clears once the control board detects that the stage 1 relay has successfully closed.
Is error code 351 on a Lennox air handler a safety concern?
The error code itself reflects a control failure rather than an immediate safety emergency, as the heating elements are not receiving power. However, ignoring the fault means your system is operating without the first stage of electric heat, which can reduce comfort and put extra demand on any remaining heating stages. A failed relay should be addressed promptly to restore proper operation and prevent additional strain on other components.
Will resetting the system clear error code 351?
A simple power reset will not permanently clear code 351 if the underlying relay or wiring fault still exists. The alarm is designed to clear automatically once the control board detects that the stage 1 relay has actually closed and the circuit is functioning correctly. Resetting power may temporarily suppress the display, but the code will return on the next call for first stage heat if the root cause has not been corrected.
Can I fix error code 351 myself?
Some basic checks, like inspecting for loose wire connections at the relay terminals, can be performed by a knowledgeable DIYer with the power off. However, testing relay coil continuity, measuring control board output voltage, and replacing components inside an air handler involves working near high-voltage electric heat elements, which poses a serious shock hazard. Most homeowners should have a qualified HVAC technician perform this diagnosis and repair.
How much does it cost to repair a Lennox 351 error code?
Repair costs depend on what has failed. Replacing a pilot relay is typically one of the less expensive fixes, with parts often ranging from $20 to $80 and labor adding to the total depending on your area and the technician's rates. If the control board is found to be at fault for not supplying voltage, board replacement can cost significantly more, generally in the range of $200 to $600 or higher for parts and labor combined.