Lennox HVAC Error Code 352

There is a problem with the air-handler's second stage electric heat (pilot relay contacts did not close or relay coil did not energize); air-handler…

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 352 error code actually means

Your Lennox heating system has detected a problem with the second stage of its electric heat, meaning it can only run at reduced heating power right now. The component that switches on the extra heating is not responding the way it should. Your home may take longer to heat up or struggle to reach the desired temperature, especially on very cold days.

Diagnostic procedure

The full 352 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check relay coil and contacts. The alarm clears after stage 2 relay is detected.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 352 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 352

Ranked by how often they cause this code
  1. 1Failed relay coil
  2. 2Burned or pitted relay contacts
  3. 3Wiring fault between control board and relay
  4. 4Control board not sending energizing voltage
  5. 5Low or unstable supply voltage

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 352

What does 352 mean on a Lennox hvac?
Error code 352 on a Lennox air handler indicates that the second stage electric heat pilot relay did not respond correctly. Either the relay coil failed to energize or its contacts did not close when the system called for second stage heat. The system will continue operating on first stage heat only until the fault is resolved. The code clears automatically once the relay is detected functioning correctly.
Is it safe to keep running my Lennox system with a 352 error?
Yes, it is generally safe to continue using the system with error 352 active, as the air handler is designed to fall back to first stage heat operation rather than shutting down entirely. Your home will still receive some heat, though capacity will be reduced. The underlying relay fault should still be repaired promptly to restore full heating output and prevent additional strain on the first stage components.
Will resetting the system clear the Lennox 352 error code?
A simple reset will not permanently clear error 352. The fault is condition-based, meaning the code clears only when the control board actually detects that the second stage relay has successfully closed. If the underlying problem with the relay coil, contacts, or wiring is not corrected, the fault will return as soon as the system calls for second stage heat again.
Can I fix Lennox error code 352 myself?
Some basic checks, such as inspecting wiring connections and verifying terminal tightness, can be done by a knowledgeable homeowner. However, diagnosing relay coil resistance, measuring live voltages at the relay terminals, and replacing components inside an air handler involves working near high-voltage electric heating circuits, which requires appropriate safety precautions and experience. A licensed HVAC technician is recommended for anything beyond visual inspection.
How much does it cost to repair a Lennox 352 error code?
Repair costs depend on the root cause. If only a wiring connection needs to be corrected, the cost may be limited to a service call fee, typically in the range of $75 to $150. Replacing the second stage relay itself usually adds $50 to $200 in parts depending on the specific component. If the control board is the source of the fault, board replacement can range from $200 to $600 or more including labor.