Lennox Hvac Error Code 401
The secondary voltage for the air-handler has fallen below 18VAC; if this continues for 10 minutes, the…
The secondary voltage for the air-handler has fallen below 18VAC; if this continues for 10 minutes, the iComfort thermostat will turn off the air-handler.
First step from the service manual
Check the indoor line voltage and transformer output voltage. The alarm clears after the voltage is higher than 20VAC for 2 seconds or after a power reset.