Error code reference

Lennox Hvac Error Code 401

The secondary voltage for the air-handler has fallen below 18VAC; if this continues for 10 minutes, the…

The secondary voltage for the air-handler has fallen below 18VAC; if this continues for 10 minutes, the iComfort thermostat will turn off the air-handler.

First step from the service manual

Check the indoor line voltage and transformer output voltage. The alarm clears after the voltage is higher than 20VAC for 2 seconds or after a power reset.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.