What the 5 Flashes error code actually means

Your furnace is detecting a flame when it should not be, specifically before it has even turned on the gas. This is a safety issue that causes the system to shut down automatically. A technician should inspect the gas valve and flame sensor before the system is restarted.

Diagnostic procedure

The full 5 Flashes procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 5 Flashes procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 5 Flashes

Ranked by how often they cause this code
  1. 1Leaking or stuck-open gas valve
  2. 2Faulty flame sensor producing a false signal
  3. 3Miswiring or short circuit in flame sensor circuit
  4. 4Failed control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 5 Flashes

What does 5 Flashes mean on a Lennox hvac?
A 5-flash error on a Lennox HVAC system means the control board has detected a flame signal while the gas valve was not commanded open. This is treated as an unsafe condition and the system shuts down as a precaution. The fault points to a possible leaking gas valve, a defective flame sensor, or a wiring issue in the flame sensing circuit.
Is a 5-flash error on a Lennox furnace dangerous?
It can be. If the code is triggered by a gas valve that is leaking or stuck open, there is a risk of uncontrolled combustion inside the furnace. The system shuts itself down specifically to prevent unsafe operation. Until the cause is confirmed, treat the situation as a potential gas-related hazard and ventilate the area if you detect any gas odor.
Will resetting my Lennox furnace clear the 5-flash error?
A power reset may temporarily clear the fault and allow the furnace to attempt a new startup cycle, but if the underlying cause is still present, the error will return. Resetting without diagnosing the root cause is not recommended, especially if a gas valve leak is involved. The error should be properly diagnosed before the system is returned to regular operation.
Can I fix a 5-flash error on my Lennox furnace myself?
Some causes, such as a shorted wire or a dirty flame sensor, may be within reach of an experienced DIYer comfortable working on furnaces. However, if the fault is caused by a leaking gas valve, this is a safety-critical repair that should be handled by a licensed HVAC technician. Do not bypass or ignore this error code before identifying the root cause.
How much does it cost to repair a 5-flash error on a Lennox furnace?
Repair costs vary depending on the cause. Flame sensor replacement is typically a lower-cost repair, generally in the range of $75 to $200 including labor. Gas valve replacement is more involved and can range from $200 to $600 or more depending on the model and labor rates in your area. Control board replacement tends to fall in a similar or higher range.