mypros+
Error code reference

LG Air Conditioner Error Code 193

Fan PCB heatsink temperature high

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the 193 error code actually means

Your LG air conditioner is detecting that a critical circuit board component has gotten too hot, above a safe temperature limit. This is a protective shutdown to prevent damage to the electronics. The problem could be a faulty temperature sensor giving a false reading, or the board may genuinely be overheating due to poor airflow or a fan issue.

Diagnostic procedure

The full 193 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check heatsink temperature sensor insertion to fan PCB; check sensor attachment to heatsink; measure sensor resistance (10kΩ ±5% at 25°C).
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 193 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of 193

Ranked by how often they cause this code
  1. 1Heatsink sensor not properly attached to heatsink
  2. 2Sensor connector not fully seated on fan PCB
  3. 3Faulty heatsink temperature sensor
  4. 4Restricted airflow around the fan PCB or heatsink
  5. 5Fan motor not operating correctly

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about 193

What does 193 mean on a LG air conditioner?
Error code 193 means the fan PCB heatsink temperature has exceeded 95°C, which is the system's protective upper limit. The unit shuts down to prevent damage to the fan circuit board components. The fault can be caused by a displaced or failed heatsink temperature sensor, or by actual overheating due to restricted airflow or a fan problem.
Is it safe to run my LG air conditioner when error code 193 appears?
No, you should not continue operating the unit while error code 193 is active. The code indicates the fan PCB heatsink has reached a potentially damaging temperature, and the system has triggered a protective shutdown for this reason. Forcing the unit to run under these conditions risks permanent damage to the fan PCB and associated components.
How much does it cost to repair a LG air conditioner showing error code 193?
If the fix is simply reseating the sensor connector or re-attaching the sensor to the heatsink, there may be no parts cost involved, though a service call fee would apply. Replacing a failed heatsink temperature sensor is generally an inexpensive repair, with parts typically in the range of $10 to $50 depending on the model. If the fan PCB itself has sustained heat damage and requires replacement, costs can rise considerably, generally falling in the range of $150 to $400 or more for parts and labor.
How do I fix error code 193 on my LG air conditioner?
Start by checking that the heatsink temperature sensor is firmly attached to the heatsink surface and that its connector is fully seated on the fan PCB. Measure the sensor's resistance at room temperature; it should read approximately 10kΩ at 25°C within a 5% tolerance. If the sensor tests correctly, inspect the heatsink for dust or debris buildup and confirm the fan motor is running at proper speed. A sensor reading outside specification requires sensor replacement, and persistent genuine overheating may indicate a fan motor or PCB issue requiring a technician.
Will resetting my LG air conditioner clear error code 193?
A power reset may temporarily clear the fault and allow the unit to restart, but the code will return if the underlying cause is not corrected. If the sensor is loose or its connector is unseated, reseating it may resolve the issue permanently. If the sensor is defective or a genuine thermal problem exists, the error code will recur until those conditions are addressed.