Model reference
LG ARUB80LT2
Heat Pump
1 document66 error codes16 service modes
Available documentation
Service Manual
- Heat Recovery Outdoor Unit R410A SERVICE MANUAL (Exploded View)31 pg
MyPros+ Max
Diagnose your LG ARUB80LT2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (66)
CodeMeaning
01Indoor unit air temperature sensor is open or short.02Indoor unit inlet pipe temperature sensor is open or short.03Transmission error between wired remote controller and indoor unit04Drain pump malfunction05Transmission error between outdoor unit and indoor unit06Indoor unit outlet pipe temperature sensor is open or short.07Different operation mode09Indoor unit EEPROM error10Indoor unit BLDC fan motor failure104Communication error between outdoor units105Transmission error between fan PCB and main PCB106Outdoor unit fan PCB IPM failure107Fan DC link low voltage error11Indoor unit transmission error113Outdoor unit liquid pipe (condenser) temperature sensor error114Outdoor unit sub-cooling inlet/outlet temperature sensor error115Outdoor unit subcooling outlet temperature sensor error151Function error of 4-way (reversing) valve in outdoor unit173Constant speed compressor fault193Fan PCB heatsink temperature high194Fan PCB heatsink temperature sensor error200Pipe detection error201HR unit liquid pipe temperature sensor error202HR unit sub-cooling inlet pipe temperature sensor error203HR unit sub-cooling outlet pipe temperature sensor error204Transmission error between HR unit and outdoor unit21Inverter compressor IPM fault22Inverter PCB assembly AC input current over error23Inverter compressor DC link low voltage24High pressure switchView all 66 error codes
25Input voltage high/low26Inverter compressor start failure28Inverter DC link high voltage error29Inverter compressor over current32Over-increase of discharge temperature of inverter compressor33Over-increase of discharge temperature of constant speed compressor34Over-increase of discharge pressure of compressor35Excessive drop of discharge pressure of compressor40Inverter compressor CT sensor fault41Inverter compressor discharge pipe temperature sensor fault42Low pressure sensor error43High pressure sensor error44Outdoor unit air temperature sensor fault45Heat exchanger temperature sensor (A) fault in outdoor unit46Outdoor unit compressor suction temperature sensor fault47Constant speed compressor discharge pipe temperature sensor fault48Heat exchanger temperature sensor (B) fault in outdoor unit50Outdoor unit 3-phase power omission error51Over-capacity52Transmission error from inverter PCB to main PCB53Transmission error from indoor unit to main PCB of outdoor unit54Wrong connection of 3-phase power supply cable59Slave outdoor unit mixed installation60Inverter PCB EEPROM error67Outdoor unit fan lock error70Constant speed compressor CT sensor error71Inverter input current (PFC) CT sensor error73AC input instant over current error743-phase power unbalance75Fan CT sensor error76Fan DC link high voltage error77Fan over current error78Fan hall sensor error79Fan start failure error86Main PCB EEPROM error87Fan PCB EEPROM error
Service modes (16)
- Auto Addressing (Indoor units and HR units)["Turn on HR unit, indoor unit, and outdoor unit power in that order.","Wait 3 minutes after power…
- Auto Pipe Detection["Ensure indoor unit auto addressing is complete.","Turn No.1 of SW02M of HR unit PCB…
- Black Box Function (Error Data Loading)["Stop indoor and outdoor units.","Press the black button for 5 seconds.","EEPROM to main micom…
- Emergency Operation (Manual Back Up)["Determine which compressor is broken.","Turn off the power.","Set dip switch of defective outdoor…
- Forced Defrosting["Set dip switches per defrost table setting.","Power reset."]
- Forced Indoor Unit Operation (Cooling)["Set SW01B dip switches per table (cooling forced operation setting).","Power reset."]
- Forced Indoor Unit Operation (Heating)["Set SW01B dip switches per table (heating forced operation setting).","Power reset."]
- Forced Oil Return["Set dip switches per forced oil return table setting.","Power reset."]
- Manual Pipe Detection["Enter central control address into each indoor unit using its wired remote control.","Turn No.1…
- Night Silent Operation["Set dip switch No.12 and No.14 ON on master outdoor unit SW01B.","Power reset main PCB.","Set fan…
- Pump Down["Close liquid SVC valve of each unit.","Close high pressure SVC valve of each unit.","Open low…
- Pump Out["Close liquid SVC valve of each unit.","Close low pressure SVC valve of each unit.","Open high…
- Refrigerant Auto Charging["Wait 3 minutes after power reset.","Set dip switches
- Refrigerant Checking Function["Wait 3 minutes after power reset.","Set dip switches
- Sensor Checking Function["Wait 3 minutes after power reset.","Set dip switches
- Vacuum Mode["Reset outdoor unit power.","Set master main PCB dip switch No.11 and No.14 ON.","Press the black…
Full entry steps, exit procedures, and test sequences are available in Max.