mypros+
Error code reference

LG Air Conditioner Error Code CH45

Condenser pipe temperature sensor error (open/short)

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the CH45 error code actually means

Your LG air conditioner has detected a problem with the temperature sensor on the condenser coil, which is part of the outdoor unit. Either the sensor itself has failed, there is a wiring problem connected to it, or the condenser is genuinely overheating. The system has stopped normal operation to prevent damage until this is resolved.

Diagnostic procedure

The full CH45 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
Confirm the fault
Power cycle the unit: switch off the breaker for 60 seconds, then restore power. If the code returns, the fault is persistent and the procedure below isolates the cause.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock CH45 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of CH45

Ranked by how often they cause this code
  1. 1Faulty condenser pipe thermistor
  2. 2Damaged or disconnected wiring harness
  3. 3Blocked or dirty condenser coil
  4. 4Low refrigerant charge
  5. 5Failed control board

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about CH45

What does CH45 mean on a LG air_conditioner?
CH45 on an LG air conditioner indicates a condenser pipe temperature sensor error. The fault is triggered when the sensor circuit is detected as open or shorted, or when the actual condenser pipe temperature rises too high. The system limits or stops operation to protect the compressor and refrigerant circuit from damage.
Is it safe to keep running my LG air conditioner with a CH45 error?
You should not continue running the unit with an active CH45 code. If the condenser is genuinely overheating, continued operation risks compressor damage and refrigerant system failures that are significantly more costly to repair. If the sensor has simply failed, operating without accurate temperature feedback removes an important protection layer from the system.
How much does it cost to repair a CH45 error on an LG air conditioner?
Repair costs depend on the root cause. Condenser coil cleaning is typically in the range of $75 to $200 as a service call. Replacing the condenser pipe thermistor generally falls between $100 and $250 including parts and labor. If a refrigerant recharge is needed, costs typically range from $150 to $400 depending on refrigerant type and the amount required. Control board replacement is the most expensive scenario, often ranging from $300 to $600 or more.
Can I fix CH45 myself or do I need a technician?
Some causes of CH45 are accessible to a knowledgeable DIYer, such as cleaning a blocked condenser coil or inspecting wiring connectors for visible damage or loose pins. However, testing the thermistor accurately requires a multimeter and knowledge of expected resistance values. Any diagnosis or repair involving refrigerant charge requires a certified HVAC technician by law.
Will resetting the unit clear the CH45 error code?
A power reset may temporarily clear the CH45 code, but it will return quickly if the underlying fault is still present. If the sensor is failed open or shorted, or if the condenser pipe temperature remains too high, the control board will detect the fault again within a short operating period. A reset alone is not a repair and should only be used as part of diagnosing whether the fault is intermittent.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass